Info (Parameter) Change
…
[7] 20h Info Change
[8] 00h High 7 bits of parameter number (always 00h for PRO SOLO Mk3)
[9] 0nnnnnnn Where nnnnnnn = low 7 bits of parameter number
[10] 00h / 01h High 7 bits of data (either 00h or 01h for PRO SOLO Mk3)
[11] 0nnnnnnn Where nnnnnnn = low 7 bits of data
[12] F7h End of exclusive
The PRO SOLO Mk3 is sent a two-byte address, which directly corresponds to a parameter. It is also sent
two bytes of data, which represent the value at the parameter. It responds by changing the data and
updating the display if necessary. The new value is NOT stored, as would be the case if you were using the
front panel to change a parameter. The list of addresses and possible data values is below.
Note: All SysEx addresses and data are range checked and out-of-range values will either be ignored or
adjusted to give a valid response.
Add. (Hex) Function Range Notes _
00 00h P01 MIDI Receive Channel 0 to 15 Corresponds to channels 1 to 16
01 01h P02 Retrigger Time 0 to 25 0 = Off / 1 to 25
02 02h P03 Note Priority 0 to 2 0 = New / 1 = Low / 2 = High
03 03h P04 Pitch Bend Range 0 to 48
04 04h P05 Portamento Controller 253 > 0 > 119 See note (1)
05 05h P06 Portamento Rate 1 to 127
06 06h P07 Portamento Type 0 or 1 0 = Fixed Rate / 1 = Fixed Time
07 07h P08 LFO to CV Controller 252 > 0 > 119 See note (2)
08 08h P09 LFO to CV Min Value 0 to 127
09 09h P10 LFO to CV Max Value 0 to 127
10 0Ah P11 LFO to CV Reset Value 0 to 127
11 0Bh P12 Coarse Tune 232 > 0 > 24 See note (3)
12 0Ch P13 Fine Tune 129 > 0 > 127 129 to 255 negative / 0 to 127 positive
13 0Dh P14 Scale 129 > 0 > 127 129 to 255 negative / 0 to 127 positive
14 0Eh P15 CV / Hz Select 0 to 2 0 = CV / 1 = Hz / 2 = 1.2V
15 0Fh P16 Gate Type 0 to 6 See note (4)
16 10h P20 Aux 1 Controller 246 > 0 > 119 See note (5)
17 11h P21 Aux 1 Min Value 0 to 127 Corresponds to -27 to +100
18 12h P22 Aux 1 Max Value 0 to 127 Corresponds to -27 to +100
19 13h P23 Aux 1 Reset Value 0 to 127
20 14h P24 Aux 1 Key Scale 0 to 127
21 15h P25 LFO to Aux 1 Controller 252 > 0 > 119 See note (2)
22 16h P26 LFO to Aux 1 Min Value 0 to 127
23 17h P27 LFO to Aux 1 Max Value 0 to 127
24 18h P28 LFO to Aux 1 Reset Value 0 to 127
25 19h P29 Aux 1 Drum Trig. Note No. 0 to 127
26 1Ah P30 Aux 2 Controller 246 > 0 > 119 See note (4)
27 1Bh P31 Aux 2 Min Value 0 to 127 Corresponds to -27 to +100
28 1Ch P32 Aux 2 Max Value 0 to 127 Corresponds to -27 to +100
29 1Dh P33 Aux 2 Reset Value 0 to 127
30 1Eh P34 Aux 2 Drum Trig. Note No. 0 to 127
31 1Fh P40 Aux 3 Controller 246 > 0 > 119 See note (5)
32 20h P41 Aux 3 Min Value 0 to 127
33 21h P42 Aux 3 Max Value 0 to 127
34 22h P43 Aux 3 Reset Value 0 to 127
35 23h P44 Aux 3 Drum Trig. Note No. 0 to 127
36 24h P50 LFO Rate 0 to 191
37 25h P51 LFO Waveshape 0 to 8 See note (6)
Continued on next page…