Vents Stream EC is a plastic sound-insulated fan designed for supply or extract ventilation of premises. It can be mounted horizontally or vertically, on the floor, wall, or ceiling. The fan is suitable for continuous operation and can be used as part of a set with parallel or in-series connection. It has an ingress protection rating of IPX4 and is rated for operation at ambient temperatures ranging from +1 °C to +40 °C.

Vents Stream EC is a plastic sound-insulated fan designed for supply or extract ventilation of premises. It can be mounted horizontally or vertically, on the floor, wall, or ceiling. The fan is suitable for continuous operation and can be used as part of a set with parallel or in-series connection. It has an ingress protection rating of IPX4 and is rated for operation at ambient temperatures ranging from +1 °C to +40 °C.

PLASTIC SOUNDINSULATED FAN
User’s manual
www.ventilation-system.com
Stream
Stream EC
EN
2
CONTENTS
Overall dimensions ............................................................................................................................................................................................................................ 8
Delivery set ............................................................................................................................................................................................................................................. 9
Brief description .................................................................................................................................................................................................................................. 9
Operation guidelines ....................................................................................................................................................................................................................... 9
Designation key ................................................................................................................................................................................................................................. 10
Technical data ....................................................................................................................................................................................................................................... 11
Mounting ................................................................................................................................................................................................................................................. 12
Electronics operation algorithm ............................................................................................................................................................................................... 18
Technical maintenance ................................................................................................................................................................................................................... 21
Troubleshooting .................................................................................................................................................................................................................................. 22
Storage and transportation regulations ............................................................................................................................................................................... 23
Manufacturers warranty ................................................................................................................................................................................................................ 24
This users manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the Stream
unit and all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should
be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the
territory of the country.
3
This unit is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the unit by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with
the unit.
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and
understand the hazards involved.
Cleaning and user maintenance shall not be made by children
without supervision.
Children shall not play with the appliance.
4
Connection to the mains must be made through a disconnecting
device, which is integrated into the fixed wiring system in accordance
with the wiring rules for design of electrical units, and has a contact
separation in all poles that allows for full disconnection under
overvoltage category III conditions.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent, or similarly qualified persons in order
to avoid a safety hazard.
Ensure that the unit is switched off from the supply mains before
removing the guard.
Precautions must be taken to avoid the back-flow of gases into the
room from the open flue of gas or other fuel-burning appliances.
The appliance may adversely affect the safe operation of appliances
burning gas or other fuels (including those in other rooms) due to
back flow of combustion gases. These gases can potentially result
in carbon monoxide poisoning. After installation of the unit the
operation of flued gas appliances should be tested by a competent
person to ensure that back flow of combustion gases does not occur.
5
All operations described in this manual must be performed by
qualified personnel only, properly trained and qualified to install,
make electrical connections and maintain ventilation units.
Do not attempt to install the product, connect it to the mains, or
perform maintenance yourself.
This is unsafe and impossible without special knowledge.
Disconnect the power supply prior to any operations with the unit.
All users manual requirements as well as the provisions of all the
applicable local and national construction, electrical, and technical
norms and standards must be observed when installing and
operating the unit.
Disconnect the unit from the power supply prior to any connection,
servicing, maintenance, and repair operations.
Only qualied electricians with a work permit for electrical
units up to 1000 V are allowed for installation. The present user’s
manual should be carefully read before beginning works.
Do not attach the product to the support using glue or adhesives. Use
only the fastening method specified in the «Users manual».
6
Check the unit for any visible damage of the impeller, the casing, and
the grille before starting installation. The casing internals must be free
of any foreign objects that can damage the impeller blades.
While mounting the unit, avoid compression of the casing!
Deformation of the casing may result in motor jam and excessive
noise.
Misuse of the unit and any unauthorised modifications are not
allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities,
sticky substances, or fibrous materials.
Do not use the unit in a hazardous or explosive environment
containing spirits, gasoline, insecticides, etc.
Do not close or block the intake or extract vents in order to ensure the
efficient air flow.
Do not sit on the unit and do not put objects on it.
The information in this users manual was correct at the time of the
documents preparation.
7
The Company reserves the right to modify the technical
characteristics, design, or configuration of its products at any time in
order to incorporate the latest technological developments.
Never touch the unit with wet or damp hands.
Never touch the unit when barefoot.
BEFORE INSTALLING ADDITIONAL EXTERNAL DEVICES, READ THE
RELEVANT USER MANUALS.
THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE.
8
H
M
Stream 100/125 (spigot ø100 mm)
D
D
D
L
L
L
Stream 100/125 (spigot ø125 mm)
D
D
D
L
L
L
Stream 150 (spigot ø150 mm)
Stream 160 (spigot ø150 mm with a rubber seal)
D
D
D
L
L
L
Ø D L B H M
Stream 100/125
100 752
253 273 148
125 679
Stream 150 150 606
160
OVERALL DIMENSIONS
9
OPERATION GUIDELINES
The unit is designed for connection to power mains with the parameters specified in the «Technical data» section.
The fan is rated for continuous operation.
Air motion direction in the system must match the pointer on the fan casing.
The Stream unit is rated as a Class II and Stream EC as Class I electrical appliance.
Ingress protection rating against access to hazardous parts and water ingress is IPХ4.
The fan is rated for operation at the ambient temperature ranging from +1 °C up to +40 °C.
DELIVERY SET
Fan – 1 pc.
Screws and dowels – 4 pcs.
Users manual – 1 pc.
Packing box – 1 pc.
Rubber seal (for the Stream 150/160 model) – 2 pcs.
BRIEF DESCRIPTION
The product described herein is a plastic sound-insulated fan for supply or extract ventilation of premises.
The fan is connected to the ø 100, 125, 150 and 160 mm air ducts.
10
DESIGNATION KEY
Stream 150 EC V
Options:
T: timer;
S: motor with increased capacity;
U: speed controller with electronic thermostat and built-in temperature sensor.
Algorithm of operation by temperature;
Un: speed controller with electronic thermostat and external temperature sensor mounted
on a 4 m long cord. Algorithm of operation by temperature;
P – smooth speed controller from 0 to 100 % and power cord with a mains plug;
R – power cord with a mains plug;
V – speed switch.
Electric motor type
_: asynchronous
EC: electronically commutated
Spigot diameter [mm]
Plastic sound-insulated fan
11
TECHNICAL DATA
To comply with the ErP 2018 regulation, a local demand controller and speed controller must be used.
12
MOUNTING
The fan is suitable both for horizontal or vertical mounting on the floor, on the wall or on the ceiling. The fan can be installed
independently or as part of a set with parallel or in-series connection.
min 1 m
13
The diameter of the spigots in the Stream 100/125 model can be changed using adapters, and in the Stream 150/160 model
using the rubber seal.
On outlet (discharge) spigot side it is necessary to install:
in case of horizontal installation – a duct with a length of at least 1 m;
in case of vertical installation – a canopy preventing moisture from getting into the fan.
The outlet spigot must always be connected to the air duct.
1
1
2
1
2
14
15
N N
High
Med
Low
L
X
N N
High
Med
Low
L
X
N N
High
Med
Low
L
X
N
L
ST
QF
QF
QF
QF
N
L
LT
N
L
ST
QF N
L
LT
L1
S
N
L
ST
QF N
L
LT
L1
X
X
X
High speed
Stream Stream ...T
Medium speedLow speed
The fan wiring diagrams
Designations on diagrams:
L – line; N – neutral; LT – external switch terminal; L1 – minimum speed terminal; High – maximum speed terminal; Med –
medium speed terminal; Low – minimum speed terminal; QF – automatic circuit breaker; S – external speed controller; ST
– external switch (for example, a light switch); X – input terminal.
16
Stream EC
L
N
L
NX1
SW
R1
R2
Designations on diagrams:
N — neutral
L — line
— grounding
R1 — internal speed controller
R2 — external speed controller
SW — DIP switch
17
Stream ...T
-+
2 min 30 min
Stream EC
Х1
Х2
R1
SW
18
ELECTRONICS OPERATION ALGORITHM
Stream...P Stream...U, Un
Stream
The fan speed without options can be controlled by voltage, as well as by thyristor controllers.
A speed controller can be purchased separately.
Warning! When adjusting the voltage, ensure that there is no unusual noise or vibration at reduced motor speed.
When adjusting the voltage, the motor current may exceed the rated current.
The fan is equipped with a thermal switch without self-reset.
Probable causes of the thermal switch tripping:
non-compliance with the operating rules
impeller jamming (clean the impeller)
motor malfunction (turn off the unit, contact the Seller)
To reset the thermostat:
Switch off the power supply.
Find and eliminate the cause of overheating.
Switch the power back on.
Thermostat
control knob
Speed
control
knob
Speed control
knob
19
The Stream ...T fan activates upon control voltage application to the LT input terminal by the external switch (e.g. indoor
light switch). After the control voltage is off, the fan continues to operate within the set time period adjustable from 2 to 30
min by the timer.
To adjust the fan turn-on delay time, turn the control knob T clockwise to increase and counter-clockwise to decrease the
turn-on delay time respectively.
WARNING! The timer circuit is live! Disconnect the fan from power supply prior to any adjustment operations.
The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments.
Use it to change the turn-off delay time and the humidity set point.
Do not use a metal screwdriver, knife, etc. for adjustment operations not to damage the circuit board.
The Stream ...U/Un fan is equipped with a TSC electronic module (speed controller with an electronic thermostat) for
automatic speed control (air flow) depending on the air temperature.
The terminal compartment incorporates 2 control knobs:
presetting speed;
setting electric thermostat threshold value.
This indicator lights when the air temperature exceeds the set value.
To set the thermostat threshold, rotate the thermostat control knob clockwise to increase or counter-clockwise to decrease
the temperature set point accordingly.
To set the fan speed (air capacity), rotate the speed control knob in the same way.
The fan operating logic may be based on temperature or timer indications:
As the air temperature drops 2 °C below the set point or if the initial temperature is below the set point, the fan operates
with the set speed.
The Stream ...P fan is equipped with a speed controller that enables switching the fan on/off and smooth speed (air flow)
regulation from minimum to maximum value.
20
Stream EC
The EC motor is controlled by sending of an external control signal from 0 to 10 V to the X2 terminal block or by the R1
internal speed controller. Control method selection is carried out by means of the SW DIP switch:
DIP switch in IN position. The control signal is set by the R1 internal speed controller that enables switching the fan on/off
and smooth speed (air flow) regulation from minimum to maximum value. Rotations are controlled from the minimum
(extreme right position) to the maximum (extreme left position). When rotating counter-clockwise, the rotations increase.
DIP switch in EXT position. The control signal is set by the R2 external control unit.
DO NOT USE A METAL SCREWDRIVER, KNIFE, ETC. FOR ADJUSTMENT
OPERATIONS NOT TO DAMAGE THE CIRCUIT BOARD
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Vents Stream EC User manual

Type
User manual

Vents Stream EC is a plastic sound-insulated fan designed for supply or extract ventilation of premises. It can be mounted horizontally or vertically, on the floor, wall, or ceiling. The fan is suitable for continuous operation and can be used as part of a set with parallel or in-series connection. It has an ingress protection rating of IPX4 and is rated for operation at ambient temperatures ranging from +1 °C to +40 °C.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI