  • Hello! I am an AI chatbot trained to assist you with the REEFE Economy Dual Hot Water Circulator Controller User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
DUAL HOT WATER
CIRCULATOR
PUMP 1
MAN
PUMP 2
MAN
AUTO
-DANGER-
HIGH VOLTAGE
DO NOT OPEN COVER
AUTHORISED
PERSONS ONLY
FPC-SERIES
DOC: RAM-30002-TC VER 1.0
Econo Recirculating Controller Installation
and Operating Instructions
PUMPCONTROL
MODEL: RAM-30002-TC
OWNER’S
OPERATION
MANUAL
2
FRONT
Top
Bottom
1. Controller enclosure must be
mounted in a vertical position.
2. Ensure mounting method does
not compromise enclosure
weather proof rating.
3. Ensure cables/conduits entering
the panel have mechanical
protection and that the
penetrations are sealed and do
not compromise the weather
proof rating of the enclosure.
PUMP 1
PUMP 2
EARTH
ACTIVE
NEUTRAL
PUMP 1 PUMP 2SUPPLY
240Vac
SUPPLY
EARTH
ACTIVE
NEUTRAL
EARTH
ACTIVE
NEUTRAL
240Vac Connections
INSTALLATION
CONNECTION
MOUNTING
DUAL HOT WATER
CIRCULATOR
PUMP 1
MAN
PUMP 2
MAN
AUTO
-DANGER-
HIGH VOLTAGE
DO NOT OPEN COVER
AUTHORISED
PERSONS ONLY
FPC-SERIES
3
SETTING UP
MATELEC TIME CLOCK
COM- 30314
54 3
12
23:36
AUTO
FRI
D+P H+ M+
MANUALRESET
Step Key Programming
1 Press P Setting 1 ON time (display 1 on)
2 Press H+/M+ Setting hours and minutes
3 Press D+ Select same everyday, dierent day, MO-FR, MO-SA,
SA-SU, MO WE FR, TU THU SA, MO-WE,
TH-SA. (if same everyday, no need to press this key)
4 Press P Setting 1 OFF time (display 1 o)
5 Press H+/M+ Setting hours and minutes of the turn o time
6 Press D+ If you want the same setting every day, there is no
need to press this key
7 Repeat steps 2~6 Set 2-17 ON/OFF times
8 Press End
1. To start switch, press Reset key
2. To adjust the present time, please press
key, then press D+, H+, M+ to adjust the Days, Hours and Minutes.
3. Programming steps as follows:
4
Weatherproof Poly Enclosure
Pump - 240Vac 6Amp (MAX)
Auto/Manual Selection
Mounting Brackets Included
OPERATION
CIRCUIT DIAGRAM
240 Vac Supply
A E
N
Active
Neutral
Earth
240VAC
Pump
P1
240VAC
Pump
P1
P
1~
Active
Neutral
Earth
240VAC
Pump
P2
240VAC
Pump
P2
P
1~
A1 A2
7 Day Time Clock
TC1
A1 A2
7 Day Time Clock
TC1
4 5
3
Timer Contacts
TC2
4 5
3
Timer Contacts
TC2
S1S1
Pump 1 Manual
Pump 2 Manual
Auto
Circuit
Breaker
CB1
Circuit
Breaker
CB1
A1 A2
7 Day Time Clock
TC2
A1 A2
7 Day Time Clock
TC2
54
NO Contact
TC1
54
NO Contact
TC1
/