Dell Storage Solution Resources Owner's manual

Type
Owner's manual

The Dell Storage Solution Resources are a powerful suite of tools that can help you manage and protect your data. With features like automated backups, data deduplication, and replication, you can rest assured that your data is safe and secure. The Resources also offer a variety of other features, such as:

  • Centralized management of all your storage devices
  • Real-time performance monitoring and reporting
  • Easy-to-use wizards and templates for common tasks
  • Integration with VMware, Hyper-V, and other leading virtualization platforms

The Dell Storage Solution Resources are a powerful suite of tools that can help you manage and protect your data. With features like automated backups, data deduplication, and replication, you can rest assured that your data is safe and secure. The Resources also offer a variety of other features, such as:

  • Centralized management of all your storage devices
  • Real-time performance monitoring and reporting
  • Easy-to-use wizards and templates for common tasks
  • Integration with VMware, Hyper-V, and other leading virtualization platforms
Dell Networking S60 and Dell Force10 S60
Switch Configuration Guide for EqualLogic SANs
Dell Storage Engineering
September 2013
2 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
Revisions
© 2013 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express
written permission of Dell Inc. is strictly forbidden. For more information, contact Dell.
Dell, the Dell logo, and the Dell badge, PowerConnect, EqualLogic, and Force10 are trademarks of Dell Inc.
March 2013
Initial release
September 2013
Updated for firmware 8.3.3.9
3 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
Table of contents
Revisions .................................................................................................................................................................................................. 2
1 Introduction ..................................................................................................................................................................................... 5
1.1 Audience ................................................................................................................................................................................ 5
1.2 Switch details ........................................................................................................................................................................ 5
1.3 Cabling diagram .................................................................................................................................................................. 6
2 Dell recommended switch configuration ................................................................................................................................. 7
2.1 Hardware configuration ..................................................................................................................................................... 7
2.2 Delete startup configuration ............................................................................................................................................. 7
2.3 Configure out of band (OOB) management port ........................................................................................................ 7
2.4 Configure route for OOB management port (optional) ............................................................................................ 8
2.5 Configure login credentials .............................................................................................................................................. 8
2.6 Enable switch ports ............................................................................................................................................................ 8
2.7 Enable LLDP ......................................................................................................................................................................... 9
2.8 Enable Jumbo Frames ....................................................................................................................................................... 9
2.9 Enable flow control ............................................................................................................................................................ 9
2.10 Configure spanning tree on edge ports ........................................................................................................................ 9
2.11 Configure port channel for LAG ..................................................................................................................................... 9
2.12 Configure SFP+ ports for LAG ......................................................................................................................................... 9
2.13 Save configuration ........................................................................................................................................................... 10
2.14 Configure additional switch ........................................................................................................................................... 10
3 Optional stack configuration ..................................................................................................................................................... 11
3.1 Delete startup configuration on first switch ................................................................................................................ 11
3.2 Configure stack on the first switch................................................................................................................................ 11
3.3 Delete startup configuration on the second switch ................................................................................................. 11
3.4 Configure stack on the second switch ......................................................................................................................... 12
3.5 Verify Stack Configuration ............................................................................................................................................... 12
3.6 Configure out of band (OOB) management port ...................................................................................................... 12
3.7 Configure route for OOB management port (optional) ........................................................................................... 12
3.8 Configure login credentials ............................................................................................................................................. 13
3.9 Configuring switch ports ................................................................................................................................................. 13
3.10 Save configuration and Reload ...................................................................................................................................... 13
4 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
Additional resources ...........................................................................................................................................................................14
5 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
1 Introduction
This document illustrates how to configure DellForce10S60 switches for use with EqualLogicPS
Series storage using Dell best practices. The recommended configuration uses link aggregation groups
(LAGs) for inter-switch connections.
If you are following the Rapid EqualLogic Configuration steps at
http://en.community.dell.com/techcenter/storage/w/wiki/3615.rapid-equallogic-configuration-portal-
by-sis.aspx, use sections 1 and 2, or 1 and 3 in this guide.
For more information on EqualLogic SAN design recommendations, see the EqualLogic Configuration
Guide at: www.delltechcenter.com/page/equallogic+configuration+guide.
1.1 Audience
This switch configuration guide describes an optimal configuration following Dell best practices for an
EqualLogic iSCSI SAN and is intended for storage or network administrators and deployment personnel.
1.2 Switch details
The table below provides an overview of the switch configuration.
Table 1 Switch specifications
Dell Networking S60 or Force10 S60
Switch vendor Dell Networking or Dell Force10
Switch model S60
Switch firmware 8.3.3.9
Note: For proper functionality, the switch must be at the switch firmware version shown in the table
above before proceeding with this configuration. Using previous firmware versions may have
unpredictable results.
The latest firmware updates and documentation can be found at: www.force10networks.com. This site
requires a login.
6 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
1.3 Cabling diagram
The cabling diagram shown below represents the Dell recommend method for deploying your servers and
EqualLogic arrays.
Figure 1 Cabling diagram
7 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
2 Dell recommended switch configuration
This section demonstrates how to configure two Dell Networking S60 or Force10 S60 switches with a
LAG. The switches are interconnected by an optional dual port 10GbE SFP+ module, and the LAG is
configured for Dynamic Link Aggregation Control Protocol (LACP).
2.1 Hardware configuration
1. Power on the two switches.
2. Connect a serial cable to the serial port of the first switch.
3. Using Putty or another terminal utility, open a serial connection session to the switch.
4. Open your terminal emulator and configure it to use the serial port (usually COM1 but this may vary
depending on your system). Configure serial communications for 9600,N,8,1 and no flow control.
5. Use optical cables to connect between the SFP+ optional modules on both switches. See this
configuration in Figure 1.
2.2 Delete startup configuration
Note: The following commands will delete all configuration settings.
FTOS>enable
FTOS#delete startup-config
Proceed to delete startup-config [confirm yes/no]yes
FTOS#reload
System configuration has been modified. Save? [yes/no]no
Proceed with reload [confirm yes/no]yes
Note: The switch will reboot.
2.3 Configure out of band (OOB) management port
FTOS>enable
FTOS>#configure
FTOS(conf)#interface ManagementEthernet 0/0
FTOS(conf-if-ma-0/0)#no shutdown
FTOS(conf-if-ma-0/0)#ip address ipaddress mask
FTOS(conf-if-ma-0/0)#exit
8 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
2.4 Configure route for OOB management port (optional)
FTOS(conf)#management route X.Y.Z.0 /24 A.B.C.1
Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for
the switch. If your management system is on the same subnet as the switch, the previous step may be
omitted. The example above assumes a class C subnet mask.
2.5 Configure login credentials
FTOS(conf)#username admin privilege 15 password 0 yourpassword
FTOS(conf)#enable password level 15 0 yourpassword
2.6 Enable switch ports
Option 1: You can enable ports individually by entering the port number.
FTOS#configure
FTOS(conf)#interface gigabitethernet 0/0
FTOS(conf-if-gi-0/0)#switchport
FTOS(conf-if-gi-0/0)#no shutdown
FTOS(conf-if-gi-0/0)#exit
FTOS(conf)#exit
Option 2: You can enable multiple ports at once using the ‘range’ parameter.
FTOS#configure
FTOS(conf)#interface range gigabitethernet 0/0 47
FTOS(conf-if-range-gi-0/0-47)#switchport
FTOS(conf-if-range-gi-0/0-47)#no shutdown
FTOS(conf-if-range-gi-0/0-47)#exit
FTOS(conf)#exit
9 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
2.7 Enable LLDP
FTOS#configure
FTOS(conf)#protocol lldp
FTOS(conf-lldp)#advertise management-tlv system-capabilities
FTOS(conf-lldp)#no disable
FTOS(conf-lldp)#exit
2.8 Enable Jumbo Frames
FTOS(conf)#interface range gigabitethernet 0/0 47
FTOS(conf-if-range-gi-0/0-47)#mtu 9252
2.9 Enable flow control
FTOS(conf-if-range-gi-0/0-47)#flowcontrol rx on
2.10 Configure spanning tree on edge ports
FTOS(conf-if-range-gi-0/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-gi-0/0-47)#exit
2.11 Configure port channel for LAG
These commands configure the switch interconnect as a LAG.
FTOS(conf)#interface Port-channel 1
FTOS(conf-if-po-1)#mtu 9252
FTOS(conf-if-po-1)#switchport
FTOS(conf-if-po-1)#no shutdown
FTOS(conf-if-po-1)#exit
2.12 Configure SFP+ ports for LAG
These commands assign 10Gb SFP+ ports to the Port Channel.
FTOS(conf)#interface range tengigabitethernet 0/48 - 49
FTOS(conf-if-range-te-0/48-49)#mtu 9252
10 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
FTOS(conf-if-range-te-0/48-49)#no shutdown
FTOS(conf-if-range-te-0/48-49)#flowcontrol rx on
FTOS(conf-if-range-te-0/48-49)#port-channel-protocol lacp
FTOS(conf-if-range-te-0/48-49-lacp)#port-channel 1 mode active
FTOS(conf-if-range-te-0/48-49-lacp)#exit
FTOS(conf-if-range-te-0/48-49)#exit
FTOS(conf)#exit
2.13 Save configuration
FTOS# copy running-config startup-config
2.14 Configure additional switch
Repeat the commands from section 2 to configure the second switch.
11 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
3 Optional stack configuration
Note: If you wish to use a stack configuration instead of LAG, follow the instructions below instead of
section 2.
One advantage of stacked switches is that they can be managed as a single switch; however firmware
updates will update all members of the stack simultaneously and therefore should only be done during
planned downtime.
3.1 Delete startup configuration on first switch
FTOS>enable
FTOS#delete startup-config
Proceed to delete startup-config [confirm yes/no]yes
FTOS#reload
System configuration has been modified. Save? [yes/no]no
Proceed with reload [confirm yes/no]yes
Note: The switch will reboot.
3.2 Configure stack on the first switch
FTOS>enable
FTOS#config
FTOS(conf)#stack-unit 0 priority 1
FTOS(conf)#stack-unit 0 stack-group 12
FTOS(conf)#stack-unit 0 stack-group 13
FTOS(conf)#exit
FTOS#copy run start
FTOS#reload
3.3 Delete startup configuration on the second switch
FTOS>enable
FTOS#delete startup-config
Proceed to delete startup-config [confirm yes/no]yes
FTOS#reload
System configuration has been modified. Save? [yes/no]no
Proceed with reload [confirm yes/no]yes
12 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
Note: The switch will reboot.
3.4 Configure stack on the second switch
FTOS>enable
FTOS#stack-unit 0 renumber 1
Note: The switch will reboot.
FTOS#config
FTOS(conf)#stack-unit 1 priority 1
FTOS(conf)#stack-unit 1 stack-group 12
FTOS(conf)#stack-unit 1 stack-group 13
FTOS(conf)#exit
FTOS#copy run start
FTOS#reload
3.5 Verify Stack Configuration
From the first switch (Master) CLI, confirm that the stack has formed:
FTOS#show redundancy
Note: The switch front panel will show a steady light in the MASTER LED for the Master unit, and a
blinking light for the Standby unit. All next configuration step must be perform from the master switch.
3.6 Configure out of band (OOB) management port
FTOS#config
FTOS(conf)#interface ManagementEthernet 0/0
FTOS(conf-if-ma-0/0)#no shutdown
FTOS(conf-if-ma-0/0)#ip address ipaddress mask
FTOS(conf-if-ma-0/0)#no shutdown
FTOS(conf-if-ma-0/0)#exit
3.7 Configure route for OOB management port (optional)
FTOS(conf)#management route X.Y.Z.0 /24 A.B.C.1
13 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for
the switch. If your management system is on the same subnet as the switch, the previous step may be
omitted. The example above assumes a class C subnet mask.
3.8 Configure login credentials
FTOS(conf)#username admin privilege 15 password 0 yourpassword
FTOS(conf)#enable password level 15 0 yourpassword
3.9 Configuring switch ports
FTOS(conf)#interface range gigabitethernet 0/047
FTOS(conf-if-range-gi-0/0-47)#mtu 9252
FTOS(conf-if-range-gi-0/0-47)#switchport
FTOS(conf-if-range-gi-0/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-gi-0/0-47)#flowcontrol rx on tx off
FTOS(conf-if-range-gi-0/0-47)#no shutdown
FTOS(conf-if-range-gi-0/0-47)#exit
FTOS(conf)#interface range gigabitethernet 1/0 47
FTOS(conf-if-range-gi-1/0-47)#mtu 9252
FTOS(conf-if-range-gi-1/0-47)#switchport
FTOS(conf-if-range-gi-1/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-gi-1/0-47)#flowcontrol rx on tx off
FTOS(conf-if-range-gi-1/0-47)#no shut
FTOS(conf-if-range-gi-1/0-47)#exit
FTOS(conf)#exit
3.10 Save configuration and Reload
FTOS#copy run start
Reload the stack to allow settings to take effect:
FTOS#reload
Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in
a non-default VLAN, refer to the documentation for your switch.
14 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs
Additional resources
Support.dell.com is focused on meeting your needs with proven services and support.
DellTechCenter.com is an IT Community where you can connect with Dell Customers and Dell employees
for the purpose of sharing knowledge, best practices, and information about Dell products and your
installations.
Referenced or recommended Dell publications:
Dell EqualLogic Configuration Guide:
http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/19852516/download.aspx
Dell EqualLogic Compatibility Matrix:
http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/19856862/download.aspx
For EqualLogic best practices white papers, reference architectures, and sizing guidelines for enterprise
applications and SANs, refer to Storage Infrastructure and Solutions Team Publications at:
http://dell.to/sM4hJT
This white paper is for informational purposes only. The content is provided as is, without express or implied
warranties of any kind.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Dell Storage Solution Resources Owner's manual

Type
Owner's manual

The Dell Storage Solution Resources are a powerful suite of tools that can help you manage and protect your data. With features like automated backups, data deduplication, and replication, you can rest assured that your data is safe and secure. The Resources also offer a variety of other features, such as:

  • Centralized management of all your storage devices
  • Real-time performance monitoring and reporting
  • Easy-to-use wizards and templates for common tasks
  • Integration with VMware, Hyper-V, and other leading virtualization platforms

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI