Advance acoustic sc100 Operating Manuallines

Category
Scrubber
Type
Operating Manuallines

Advance acoustic sc100 is a versatile cleaning machine designed to make floor maintenance effortless. With its 3-liter solution tank capacity, it efficiently cleans various surfaces. The dual solution buttons allow you to choose between normal and heavy-duty cleaning modes. The machine's cylindrical brush and squeegee bars ensure effective scrubbing and drying, leaving your floors spotless.

Advance acoustic sc100 is a versatile cleaning machine designed to make floor maintenance effortless. With its 3-liter solution tank capacity, it efficiently cleans various surfaces. The dual solution buttons allow you to choose between normal and heavy-duty cleaning modes. The machine's cylindrical brush and squeegee bars ensure effective scrubbing and drying, leaving your floors spotless.

9435 Winnetka Avenue North
Brooklyn Park, MN 55445
www.advance-us.com
Phone 800-850-5559
Fax 800-989-6566
240 Superior Boulevard
Mississauga, Ontario, Canada L5T 2L2
www.nilfisk-advance.ca
Phone 800-668-8400
Fax 8 0 0 -2 63 -5111
ATTENTION! Do not use the machine before you have read and understood the Instructions for Use Manual.
2. Fill the solution tank with clean
water, not to exceed 100° F.
3. The tank cap can be used for
dosing the detergent. One full cap
is 30 ml giving 1% detergent of the
0.8 gal (3 L) tank capacity. (*)
4. Connect the power plug to an
electrical socket.
1. Release the handle to remove the
tank assembly.
19. Clean the squeegee bars and
the cylindrical brush with water.
Check for wear and replace when
necessary.
17. Remove the squeegee bars. 18. Remove the cylindrical brush by
turning the side knob clockwise.
20. Wipe down the machine using a
damp cloth, and where needed
use a neutral cleaning product.
Then store the machine in a clean
and dry place.
14. Disconnect the power plug from
the electrical socket and rewind
the cord starting at the machine
and place it in the cord holder.
13. Park the machine in the upright
position.
Turn off the machine by pressing
the start/stop button.
Press the main switch to “0”.
9. Move the machine with the handle
and start cleaning the oor.
11. The red LED blinks when the
machine is getting low on solution
and has a xed light when empty.
Empty the recovery tank and
rell the solution tank to continue
working.
12.
To use the manual suction hose, press
the main button to start the machine
in upright position. Turn the hose
connection to ON and use the suction
tube. When done turn hose connection
to OFF. (**)
15. Empty the recovery and solution
tank. Clean them with water.
16. Check and clean the solution and
vacuum lter regularly.
10. For double scrubbing, ip the
pedal to lift/lower squeegees.
5. Turn on the machine with the main
switch to “I”.
6. Press the black pedal to put the
machine in working position.
7. Press the start/stop button to start
the machine.
8. Press one of the solution buttons,
according to the type of cleaning to
be performed:
1 drop - normal cleaning
2 drop - heavy duty cleaning
When nished using
(*) ALWAYS FOLLOW THE DETERGENT DOSING RECOMMENDATION ON THE LABEL OF THE CHEMICAL PRODUCT USED.
(**) THE MANUAL SUCTION HOSE IS INCLUDED ACCESSORY ONLY FOR THE FULL PACKAGE VERSION; FOR THE BASIC VERSION IS AN OPTION.
OPERATING GUIDELINES
SC100
All manuals and user guides at all-guides.com
all-guides.com
9435 Winnetka Avenue North
Brooklyn Park, MN 55445
www.advance-us.com
Phone 800-850-5559
Fax 800-989-6566
240 Superior Boulevard
Mississauga, Ontario, Canada L5T 2L2
www.nilfisk-advance.ca
Phone 800-668-8400
Fax 8 0 0 -2 63 -5111
The machine
doesn’t work
as it should?
The suction
doesn’t work
as it should?
The machine
doesn’t clean
as it should?
The brush
doesn’t work
as it should?
TROUBLESHOOTING
SC100
1. Check if the power supply cable is
damaged, faulty or disconnected
from the electrical mains.
2. Check if the recovery tank is full.1. If applicable, check if the manual
suction hose connection is turned
to “OFF”.
1. Check if you have selected the right
solution settings or the solution
tank is empty.
2. The main switch is broken. (*)
3. Check if the squeegee bars are
dirty or the blades are worn or
damaged.
2. Check if the solution lter is dirty.
Clean it if needed.
1. Check if the cylindrical brush is
correctly installed and not worn out.
Replace when necessary.
3. The push button panel is broken. (*)
(*) For these causes the maintenance
procedure must be performed by an
authorized Advance Service Center.
For further information refer to the
Service Manual, available at any
Advance Service Center.
4.
Check if the inspection compartment
is dirty. Check if the recovery vacuum
hose is disconnected or dirty.
3. Check if the holes in solution
dispensers are clogged. Remove
them and clean if needed.
ATTENTION! Do not use the machine before you have read and understood the Instructions for Use Manual.
All manuals and user guides at all-guides.com
1 / 1

Advance acoustic sc100 Operating Manuallines

Category
Scrubber
Type
Operating Manuallines

Advance acoustic sc100 is a versatile cleaning machine designed to make floor maintenance effortless. With its 3-liter solution tank capacity, it efficiently cleans various surfaces. The dual solution buttons allow you to choose between normal and heavy-duty cleaning modes. The machine's cylindrical brush and squeegee bars ensure effective scrubbing and drying, leaving your floors spotless.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

Ask the document