Sophos SG 330 Operating Instructions Manual

Type
Operating Instructions Manual

This manual is also suitable for

Operating Instructions
SG 310/330 Rev. 2
1SG 310/330 Rev. 2
Operating Instructions
Foreword
We are pleased to welcome you as a new customer of our Sophos SG appliances.
To install and configure the hardware appliance you can use the following
documents:
Ì Hardware Quick Start Guide: Connection to the
system peripherals in a few steps
Ì Operating Instructions: Notes on the security and
commissioning of the hardware appliance
Ì Administration Guide: Installing and configuring the software appliance
The Hardware Quick Start Guide and the Safety Instructions are also delivered
in printed form together with the hardware appliance. The instructions must be
read carefully prior to using the hardware and should be kept in a safe place.
You may download all user manuals and additional documentation from the
support webpage at: sophos.com/support
Security Symbols
The following symbol and its meaning appears in the Hardware Quick Start
Guide, Safety Instructions and in these Operating Instructions.
Caution and Important Note. If these notes are not correctly observed:
Ì This is dangerous to life and the environment
Ì The appliance may be damaged
Ì The functions of the appliance will be no longer guaranteed
Ì Sophos shall not be liable for damages arising from a
failure to comply with the Safety Instructions
Designed Use
The hardware appliances are developed for use in networks. The SG 310/330
models may be operated as a standalone appliance. The hardware appliance can
be used in commercial, industrial and residential environments.
The SG 310/330 models belongs to the appliance group A.
The hardware appliance must be installed pursuant to the current installation
notes. Otherwise failure-free and safe operation cannot be guaranteed. The EU
declaration of conformity is available at the following address:
Sophos Technology GmbH
Amalienbadstr. 41/Bau 52
76227 Karlsruhe
Germany
2SG 310/330 Rev. 2
Operating Instructions
CE Labeling, FCC and Approvals
The SG 310/330 appliances comply with FCC Class A, CE, C-Tick, VCCI and UL.
Important Note: For computer systems to remain CE and FCC compliant, only CE
and FCC compliant parts may be used. Maintaining CE and FCC compliance also
requires proper cable and cabling techniques.
Operating Elements and Connections
SG 310/330 Rev. 2
*
1 x COM
(RJ45)
2 x
USB 3.0
2 x 10 GbE
SFP+ – fixed
8 x GbE copper – fixed.
Incl. 2 bypass pairs
(ports E0/1 and E2/3)
1 x expansion bay
(shown here with optional
FleXi Port module)
Micro USBNavigation
for LCD
Multi-function
LCD display
2 x GbE SFP –
fixed
SG 310/330
1 x
USB 3.0
Power supply
Power switch1 x
HDMI
Connector for optional
PoE Power Module
Connector for optional 2nd
external power supply
* The displayed front image is of SG 330 device. The SG 310 device may vary slightly.
3SG 310/330 Rev. 2
Operating Instructions
LED Status
Power (LED Display)
Power Supply Acitve Green
Power Supply Failure Red
SSD Active Blue
LEDs on each RJ45 Ethernet connector
ACT/LNK
(Left LED)
Green Constantly 1. The Ethernet port is receiving power.
2. Good connection between the Ethernet port and hub.
Flashing The adapter is sending or receiving network data. The
frequency of the flashes varies with the amount of traffic.
Off 1. The adapter and switch are not receiving power.
2. No connection between both ends of network.
3. Network drivers have not been loaded
or do not function correctly.
Speed
(Right LED)
Amber On The Ethernet port is operating at 1,000 Mbps.
Green On The Ethernet port is operating at 100 Mbps.
Off The Ethernet port is operating at 10 Mbps.
LEDs on each SFP connector
ACT/LNK Green Constantly 1. The SFP connector is receiving power.
2. Good linkage between the SFP connector and hub.
Flashing The adapter is sending or receiving network data. The
frequency of the flashes varies with the amount of traffic.
Off 1. The adapter and switch are not receiving power.
2. No connection between both ends of network.
3. Network drivers have not been loaded
or do not function correctly.
LEDs on each SFP+ connector
ACT/LINK
(Left LED)
Green Constantly 1. The SFP+ connector is receiving power.
2. Good linkage between the SFP+ connector and hub.
Flashing The adapter is sending or receiving network data. The
frequency of the flashes varies with the amount of traffic.
Off 1. The adapter and switch are not receiving power.
2. No connection between both ends of network.
3. Network drivers have not been loaded
or do not function correctly.
ACT/LINK
(Right LED)
Blue On The SFP+ connector is operating at 10,000 Mbps.
Amber On The SFP+ connector is operating at 1,000 Mbps.
Off Either the LED is not working or the SFP+ connector
is operating at a speed below 1,000 Mbps.
LAN Bypass (LED Display)
LAN Bypass Active Green
LAN Bypass Off Off
Back side
Power Supply Green Constantly Power
Off No power
4SG 310/330 Rev. 2
Operating Instructions
Traffic on interface
Executable Actions
Ì Change IP Address: This option enables the user to change the interface’s IP
address and netmask. All available and enabled IP addresses can be changed.
Ì Reboot machine: The security appliance is rebooted. The reboot
action will shut down the system completely and reboot.
Ì Shut down: The security appliance is shut down. The shut down action allows
you to turn off the system, and allows you to cleanly stop all running services.
Ì Factory reset: All settings are reset to the factory settings. The factory
reset function sets all of the configuration settings and options to their
original state. All data entered after the initial installation will be deleted,
including the HTTP proxy cache, the entire email queue, accounting
and reporting data, passwords, and uninstalled Up2Date packages.
The version of the software will not change. That is, all firmware
and pattern updates that have been installed will be retained.
Ì Disable OTP (One Time Password) authentication: The OTP
authentication will be disabled for the selected options. This feature
only handles webadmin and shell access options if they are enabled.
Sophos UTM version and Appliance Uptime
CPU load information and Average Load in the last 1, 5 and 15 minutes
Memory usage
LCD and Control Keys
The Sophos SG 310/330 units have an LCD and an operating unit with four
membrane keys. In the LCD, 16 characters per line can be displayed. The display
contains in four cycling views information on the hardware and specific system
states.
After the security appliance has booted this message is displayed.
SOPHOS
Protection
UTM 9.xxx
10 days 01:43:17
CPU xx%
xx% yy% zz%
RAM x% y GB
SWAP x% y GB
all in x kbits/sec
out y kbits/sec
5SG 310/330 Rev. 2
Operating Instructions
Control Key Functions
The current menu is left. When the key is pressed a couple of times, the
modifications are discarded and the initial state will be displayed.
These keys are used to switch between the different menus and/or characters.
Pressing executes the configured action.
Change IP Address
S.NO. Action Item/press What you see on the LCD What it means
1.
Config menu
1. Change IP addr
2.
Interface eth0
192.168.0.1/24
3.
Selects interface
4.
IP address (Eth0)
192.168.0.1
Edit IP address
5.
Changes digit at cursor position
6.
IP address (Eth0)
192.168.0.1
Moves cursor to the
next right position
or
Exits edit mode without saving
7.
eth0 Netmask
24
Displays netmask value after
the last IP address digit
8.
Change netmask value
9. Saves changed IP address
and netmask
Reboot Machine
S.NO. Action Item/press What you see on the LCD What it means
1.
Config menu
1. Change IP addr
2.
x1
Config menu
2. Reboot Machine
3.
Shutting down
Are you sure? n
4.
Toggles between “y“ and “n“
5.
Selects choice
6SG 310/330 Rev. 2
Operating Instructions
Shut Down
S.NO. Action Item/press What you see on the LCD What it means
1.
Config menu
1. Change IP addr
2.
x2
Config menu
3. Shutdown
3.
Rebooting
Are you sure? n
4.
Toggles between “y“ and “n“
5.
Selects choice
Shut Down
S.NO. Action Item/press What you see on the LCD What it means
1.
Config menu
1. Change IP addr
2.
x3
Config menu
4. Factory Reset
3.
All Data erased!
Are you sure? n
4.
Toggles between “y“ and “n“
5.
Selects choice
Disabling OTP (One Time Password) Authentication
S.NO. Action Item/press What you see on the LCD What it means
1.
Config menu
1. Change IP addr
2.
x4
Config menu
5. OTP Recovery
3.
Disable OTP
Not available
Displayed if no option to
disable is available
or
Disable OTP
xxxxxx
4. Selects feature to
disable (if enabled)
5.
Disable xxxxxx
Are you sure? n
6.
Toggles between “y“ and “n“
7.
Selects choice
7SG 310/330 Rev. 2
Operating Instructions
Putting into Operation
Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of
used batteries according to the instructions.
Scope of Supply
The supplied parts are indicated in the Hardware Quick Start Guide.
Mounting Instructions
The SG 310/330 appliances are designed for use in racks. Please consider the
following security tips:
Important Note: Functional reliability outside of a rack cannot be guaranteed.
Warnings and Precautions
The appliance can be operated safely if you observe the following notes and the
notes on the appliance itself.
Rack Precautions
Ì Ensure that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on them.
Ì In single rack installation, stabilizers should be attached to the rack.
Ì In multiple rack installations, the racks should be coupled together.
Ì Always make sure the rack is stable before
extending a component from the rack.
Ì You should extend only one component at a time—extending two or
more simultaneously may cause the rack to become unstable.
General Server Precautions
Ì Review the electrical and general safety precautions that came
with the components you are adding to your appliance.
Ì Determine the placement of each component in
the rack before you install the rails.
Ì Install the heaviest server components on the
bottom of the rack first, and then work up.
Ì Allow the hot plug hard drives and power supply
modules to cool before touching them.
Ì Always keep the rack‘s front door, all panels and server components
closed when not servicing to maintain proper cooling.
8SG 310/330 Rev. 2
Operating Instructions
Rack Mounting Considerations
Ì Ambient operating temperature: If installed in a closed or multi-unit rack
assembly, the ambient operating temperature of the rack environment
may be greater than the ambient temperature of the room. Therefore,
you should install the equipment in an environment compatible
with the manufacturer’s maximum rated ambient temperature.
Ì Reduced airflow: Equipment should be mounted into
a rack with sufficient airflow to allow cooling.
Ì Mechanical loading: Equipment should be mounted into a rack so that a
hazardous condition does not arise due to uneven mechanical loading.
Ì Circuit overloading: Consideration should be given to the connection
of the equipment to the power supply circuitry and the effect that any
possible overloading of circuits might have on overcurrent protection
and power supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
Ì Reliable ground: Reliable grounding must be maintained at all times.
To ensure this, the rack itself should be grounded. Particular attention
should be given to power supply connections other than the direct
connections to the branch circuit (i.e., the use of power strips, etc.).
Rack Mounting Instructions
To mount the appliance to the rack you need the delivered rack-mount brackets.
There are a variety of rack units on the market, which may mean the assembly
procedure will differ slightly. You should also refer to the installation instructions
that came with the rack unit you are using.
Important Note: Make sure you use the screws supplied with the rack-mount
brackets. Using the wrong screws could damage the hardware appliance and
would invalidate your warranty. Please observe the mounting instructions for
your rack.
1. Attach the rack-mount brackets to the appliance.
Place the appliance on a hard, flat surface with the front panel facing you.
Attach the rack–mount brackets to the left and right side of the appliance
with the supplied screws.
Make sure the brackets are properly attached to the appliance.
2. Choose the rack location.
Leave enough clearance in front of the rack so that you can open the front
door completely (~60 cm/25 inches).
Leave approximately 80 cm/30 inches of clearance in the back of the rack
to allow for sufficient airflow and ease in servicing.
This product is for installation only in a restricted access location (dedicated
equipment rooms, service closets and the like).
3. Slide the appliance into the rack.
4. Attach the brackets to the rack with the appropriate screws (not included).
9SG 310/330 Rev. 2
Operating Instructions
Connection and Configuration
How to connect the appliance is described in the Hardware Quick Start Guide. For
configuration you can follow the initial setup wizard described in the WebAdmin
Quick Start Guide or cancel it and perform a manual setup (see the Sophos UTM
Administration Guide).
SFP GBIC Ports
The SG 310/330 models provide the option to add Sophos FleXi Port network
modules with SFP (1 GbE) or SFP+ (1/10GbE) GBIC Ports. The abbreviation SFP
GBIC stands for small form-factore plugable GigaBit interface converter, a flexible
interface which changes electronic signals into optical signals. The converters
used with the appliance are often also called Mini-GBIC or New GBIC.
To use SFP GBIC ports, you will need the appropriate SFP GBIC modules. These
modules are not delivered with the appliance but available through your Sophos
partner. There are different module types. The required type is determined by the
existing network. The following SFP GBIC module types may be used:
SFP:
1000 Base-T
IEEE 802.3 - 1 Gbit/s via Ethernet cable. An Ethernet cable category 5 covers a
maximum distance about 100 meters.
1000 Base-SX
IEEE 802.3 - 1 Gbit/s via fiberglass. Multi-mode fiberglass cables (MMF) cover a
distance of 200 m to 550 m.
1000 Base-LX
IEEE 802.3 - 1 Gbit/s via fiberglass. Here, exclusively singlemode-fiber glass is
used. This transmission option covers approximately 10 km.
SFP+:
10GBase-SR
IEEE 802.3 - 10 Gbit/s via fiberglass. Multi-mode fiberglas cables cover a
distance of up to 400 m.
10GBase-LR
IEEE 802.3 - 10 Gbit/s via fiberglass. Single-mode fiberglas cover a distance of
approximately 10 km
Note: The SFP+ ports of the Sophos FleXi Port modules are dual-rate capable
supporting both 1GbE and 10GbE speeds when using appropriate GBICs also
supporting both rates.
Caution: The SFP GBIC and SFP+ ports use lasers to transmit signals over
fiber optic cable. The lasers are compliant with the requirements of a Class 1
Laser equipment and are inherently eye-safe in normal operation. However, you
should never look directly at a transmit port when it is powered on. Always install
appropriate and UL approved Laser Class I Transceivers, rated 3.3Vdc, max. 1W,
in the fiber ports before using the fiber ports.
10SG 310/330 Rev. 2
Operating Instructions
Installing a SFP GBIC module:
Please read the operation manual to the SFP GBIC module. Carefully insert the
SFP GBIC module into the port until it engages. The interface is immediately
ready for use.
Removing a SFP GBIC module:
1. Remove the fiberglass cable from the module which you wish to remove.
2. Remove the module carefully from the port.
Depending on when you purchased your SFP GBIC module, it may have any of
three different release mechanisms: a plastic tab on the bottom of the mini-
GBIC, a wire bail, or a plastic collar around the mini-GBIC.
Please read the operation manual to the SFP GBIC module.
Serial Console
You can connect a serial console to the COM port of the Sophos SG Firewall
hardware appliances. You can use, for instance, the Hyperterminal terminal
program which is included with most versions of Microsoft Windows to log on to
the appliance console. Use an RJ45 to DB9 adapter cable or the provided USB
cable to connect the console to your hardware appliance.
The required connection settings are:
Ì Bits per second: 38,400
Ì Data bits: 8
Ì Parity: N (none)
Ì Stop bits: 1
Access via the serial console is activated by default on ttyS1. The connections of
the appliances and the respective functionality are listed in chapter “Operating
Elements and Connections.
Operating Instructions
United Kingdom and Worldwide Sales
Tel: +44 (0)8447 671131
North American Sales
Toll Free: 1-866-866-2802
Australia and New Zealand Sales
Tel: +61 2 9409 9100
Asia Sales
Tel: +65 62244168
© Copyright 2018. Sophos Ltd. All rights reserved.
Registered in England and Wales No. 2096520, The Pentagon, Abingdon Science Park, Abingdon, OX14 3YP, UK
Sophos is the registered trademark of Sophos Ltd. All other product and company names mentioned are
trademarks or registered trademarks of their respective owners.
18-05-22 OINA (DD-3006)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Sophos SG 330 Operating Instructions Manual

Type
Operating Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI