Artos F904A-VO Installation guide

Category
Sanitary ware
Type
Installation guide
904A30513
www.artos-westover.com
Installation Guide
3/4 THERMOSTATIC VALVE F904A-VO
This publication is for illustrative purposes only and we reserve the right to change details at anytime as deemed necessary.
Mixed water temperature
Maximum: 120°F
Hot Water Supply Temperature
Maximum: 185°F
Minimum: 50°F higher than mixed
Advisable: 150°F - 160°F
Minimum difference between hot and mixed temperature 50°F
Operating Pressure
Maximum: 125psi
Minimum: 20psi
Recommended: 30 - 95psi
Operating pressures (on hot and cold lines) should be kept as balan-
ced as possible, in order to assure the maximum efficiency.
Standards
ASSE 1016.ASME A112.18.1/CSA B125.1 Certified
Operating Specifications
904A30513
Read through all of these instructions
This product is part of a custom shower or bath system. Carefully
plan the installation before beginning. Decide location and
spacing of all components in the system (see typical systems at the
back of this booklet).
The top outlet is for the shower components and the bottom outlet is
for a tub spout. Blank off the tub outlet if not using
Observe all local building and plumbing codes and shut off the main
water supply before commencing pipe work
If soldering close to the valve, remove the headwork to avoid dam-
Prior to Installation
Connect the hot 3/4” supply to the left side of the valve (viewed from
the front) and the cold supply to the right
Ensure that the valve is upright and level and secure it to a ply
wood backer if there is room or secure pipes firmly to framework
Provide a hole (min 4”, max 5”diameter) in the rough wall material
for access to the stops
Install the Thermostatic Valve
904A30513
Measurements
DIAGRAM A
904A30513
MIN 3.25”
MAX 5-1/2”
0.75”
2 x 3/4” NPT Outlets (1 each side)
2 x 3/4” NPT Inlets (1 each side)
Installation Depth
Complete the installation
Remove filters/stops and flush the supply lines to remove any de-
bris. Re fit the stops/filters.
Connect outlet(s) to the chosen controls
Finish the wall surface
904A30513
904A30513
904A30513
For best results, keep the following in mind to retain the high quality finish
of your ARTOS faucet:
• Use a soft, dampened sponge or cloth. On no account should you use an
abrasive material such as a brush, scouring pad or steel wool to clean sur-
faces.
• Test your cleaning agent solution on an inconspicuous area before apply-
ing to the entire faucet.
• Wipe surfaces clean and rinse completely with water immediately after
applying cleaning agent.
An ideal cleaning technique is to rinse faucet thoroughly and blot dry any
water from the surface after each use.
ARTOS faucets are guaranteed for life against leaks and fin-
ishing defects for as long as the original purchaser owns it.
Damage caused by accident, misuse, abuse, improper installation, im-
proper cleaning or alteration will void the warranty. This warranty does
not cover replacement parts where damage is caused by normal wear and
tear. Westover, Inc is not responsible for labor charges, installation or oth-
er incidental or consequential costs. Proof of purchase must be provided
with all claims.
PLEASE REGISTER THIS PRODUCT ONLINE AT WWW.ARTOS-WESTOVER.COM
Item
Serial
Care and Maintenance
Limited Lifetime Warranty