Acer X1285 User manual

Category
Projector lamps
Type
User manual

This manual is also suitable for

English
This instruction is only for profession maintainer. End user should contact
retailer or acer local service center for lamp replacement.
Replacing the Lamp
The projector will detect the lamp life itself. It will show you a warning message
"Lamp is approaching the end of its useful life in full power operation.
Replacement Suggested!"
When you see this message, change the lamp as soon as possible. Make sure the
projector has been cooled down for at least 45 minutes before changing the lamp.
WARNING: Lamp compartment is hot! Allow it to cool down before changing
lamp!
To remove the lamp:
Turn the projector off by pressing (POWER). Allow the projector at least 45
minutes to cool down. Disconnect the power cord.
1 Use a screwdriver to remove the screw(s) from the cover. (Illustration #1)
2 Push up and remove the cover.
3 Use a screwdriver to remove the screw from the inner cover. (Illustration
#2)
4 Remove the lamp protection film. (Illustration #3)
5 Remove the screw that secures the lamp module (Illustration #4).
6 Disconnect the lamp connector from the projector. Lift the handle so that
it stands up. Pull out the lamp module by force (Illustration #5).
To replace the lamp module, use a new lamp and reverse the above steps
(Illustrations #6- #9 ).
WARNING: To reduce the risk of personal injury, do not drop the lamp module
or touch the lamp bulb. The bulb may shatter and cause injury if it is dropped.
8
7
6
5
4
2
1
1
2
3
2
1
1
9
9
1
8
  • Page 1 1

Acer X1285 User manual

Category
Projector lamps
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI