Emberglow CVS303 Installation guide

Type
Installation guide

This manual is also suitable for

LP (Propane) Conversion
A. Replace the Natural Gas Orifice Holder (Part #17) from
Kit (Model CVS-303 or RVS304) with
the L.P. Orifice Holder(#19) . This kit also contains (2) L.P Orifices, Part 20 and Part 21. Part 20,
the orifice with the small inner hole is used on the 18” Log Sets. Part 21 (orifice with the larger
hole) is used on 24” and 30” log sets. Install the correct orifice into the LP orifice holder (See
Figure 2).
Now install the Orifice Holder directly to the Burner System for proper operation. (See Figure 1)
NOTE: Refer to the Safety Pilot Valve instructions supplied with the Model CVS-303 or RVS 304
for detailed instructions on pilot installation.
B. To Replace the Natural Gas Pilot Burner Orifice with the L.P./ Propane Orifice (Not Shown ) sup-
plied with this kit:
NOTE: Refer to the detailed Safety Pilot Illustration on front cover for placement
of the L.P. Pilot Orifice.
C. Replace Heavy Media (Granules) supplied with the Natural Gas Log set with ACC18 Vermiculite
Granules, sold separately. DO NOT USE Heavy Media Granules as improper combustion will
occur. After the Vermiculite Bed has been put in place, spread the Glowing Embers (insulation
type material) supplied with the Gas Log Set over the Vermiculite Bed.
Figure 1
SHM International • 3140 Moon Station Road • Marietta GA • 30144• 1-800-229-5647
Figure 2
3/8” Locknut is
included with the
gas log sets
0
0
o
Air Holes
Orifice Holder
Orifice
To Burner
Remove Pilot Supply Line Nut (Part #10) from the Pilot Burner (Part #5). Replace Natural Gas
Orifice with the L.P. Gas Orifice (Not Shown) included with this conversion kit.
  • Page 1 1

Emberglow CVS303 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI