Marantec Control 45 Owner's manual

Category
Garage Door Opener
Type
Owner's manual

This manual is also suitable for

Marantec Control 45 is a control unit for industrial-use operators, providing various functions and safety features for automatic doors. It enables variable speed control, soft starts and stops, and programmable travel limits. Additional functions include inputs for external control elements, photocells, closing edge safety devices, and signal lights, allowing for customized automation and safety solutions. It also features an automatic timer function and a testing option for closing edge safety devices.

Marantec Control 45 is a control unit for industrial-use operators, providing various functions and safety features for automatic doors. It enables variable speed control, soft starts and stops, and programmable travel limits. Additional functions include inputs for external control elements, photocells, closing edge safety devices, and signal lights, allowing for customized automation and safety solutions. It also features an automatic timer function and a testing option for closing edge safety devices.

Instructions for Initial Operation and
Wiring Scheme Manual
Control unit for Operators – Industrial Use
GB
Control 45-FU
Please keep these instructions for further reference.
English / Page 2
1. Contents
Chapter Page
1. Contents 2
2. Meaning of symbols 3
3. Pictures to control unit Control 45-FU 5
4. Important security notes 7
5. General facts for frequency transformer operator 9
6. Initial operation of control unit Control 45-FU
6.1 Connection control unit — operator 11
6.2 Connection control unit — door leaf 12
6.3 Adjustment of the control cams 15
6.3.1 Setting the soft stop travel limit CLOSE 15
6.3.2 Setting the reference point 16
6.3.3 Setting the soft stop travel limit OPEN 17
7. Display functions and programming possibilities
7.1 Summary of display functions programming possibilities 18
7.2 Programming of operator's basic functions 21
7.3 Programming of extended operatior's functions 23
8. Connection of closing edge safety device 29
9. Connection and initial operation of the extensions
9.1 Remote control 31
9.2 External control elements (description of function) 32
9.2.1 with system plugs 32
9.2.2 without system plugs 33
9.3 External photocell 36
9.4 Travel limit signals (relay) 38
9.5 Signal lights for automatic function 40
9.6 Lighting (relay for special functions) 41
10. Error numbers 43
11. Appendix
11.1 Wiring diagram Control 45-FU 44
11.2 Test instructions 46
English / Page 3
Warning! Risk of personal injury!
There follow important safety advice which must be followed in
order to prevent personal injuries!
Attention! Risk of material damage!
There follow important safety advice which must be followed in
order to prevent material damage!
2. Meaning of symbols
Operational check:
After connecting and programming most of the control
elements, it is advisable to test the function of the control unit.
Any fault can then be detected immediately and time is saved
in trouble-shooting.
Advice / Tip
English / Page 4
2. Meaning of symbols
ON, mains voltage
Impulse
Malfunction
OPEN
CLOSE
Power limit
Stop
External control elements
Electronic aerial
External photocell
Transmitter
(optosensor, photocell)
Receiver
(optosensor, photocell)
Closing edge safety device
RPM sensor
To control unit
Cable slack switch
Connection lead
Wicket door switch
Automatic timer
Lighting
Frequency transformer
Symbols of control unit, operator etc.:
~
/
~
English / Page 5
Fig. 1: Overview of door and surrounding area
Fig. 2: Membrane keypad and key switch
Fig. 3: Control panel of control unit
3. Pictures to control unit Control 45-FU
Overview of door and surrounding
area:
A Control panel of control unit
B Connectons in control unit
C Connections in door operator
D Setting the reference point
E Site electric socket CEE-Standard 16A
F Connection to door leaf
Key switch:
0 red OFF
IblueON
Control lights:
1. Photocell
2. OPEN travel limit
3. Automatic timer
4. CLOSE travel limit
5. Reference point
6. Malfunction
7. Impulse
8. Voltage
15. Testing of closing edge
Control elements:
10. PROGRAMMING button
11. OPEN button
12. CLOSE button
13. STOP button
D
C
A
B
E
F
P
2
1
3
4
5
6
7
8
1
2
3
3
1
15
2
12
11
13
0
I
O
1
O
2
O
8
O
3
O
7
O
11
O
10
O
4
O
12
O
5
O
6
48!5 2
!2 !3 !1
English / Page 6
Fig. 4: Connections in control unit (extract)
3. Pictures to control unit Control 45-FU
Plug connections:
25. X30 Closing edge safety device
26. X20a Electronic aerial
27. X10 External control elements
28. X20 External photocell
29. X40 RPM sensor
31. X5 Keypad on cover
32. X8b Signal light relay
33. X8a Travel limit relay
35. X8d Relay for special functions
41. X44 Frequency transformer
Connecting terminals:
39. X2c External control elements
Programming switches:
36. S20 Photocell function
37. S20a Photocell function
English / Page 7
4. Important safety advice
This control unit may only be connected and put into operation by qualified and
suitable trained specialist personnel. For the purpose of this description qualified
and suitable trained specialist personnel are persons who are adequately instructed
or supervised by qualified electricians and are thus in a position to recognize the
hazards that electricity can cause. Moreover, they must hold qualifications consistent
with the work being carried out. This presupposes in particular
• knowledge of applicable electro-technological regulations,
• training in the use and maintenance of adequate safety equipment,
• first aid training.
Attention!
Before carrying out any cabling work, it is essential to
disconnect the control unit from the mains supply.
• Observe local safety regulations!
• Always lay mains cable and control cable separately.
Control voltage 24 V DC.
Attention!
Before putting the control unit into operation, it is essential to
ensure, that there are no persons or objects within the door's
aeria of operation, since a number of settings set the door in
motion!
All available emergency command devices must be tested prior to initial operation.
• The door operator must be installed with the door closed!
• After installation and initial operation, those persons or their representatives
responsible for operating the door system must be shown how the door
system works!
• No cables should be fed into the top of the control unit!
• For technical reasons, the first time the control unit is switched on, the door
opens fully.
English / Page 8
4. Important safety advice
Attention!
Wait 60 sec. before starting installation works on motor!
After separation of the operator from mains the frequency
transformer still features a residual stress.
Attention!
Special note for installation according to protection category
IP 65: At the very latest following initial operation, the cable
with plug allowing connection to the mains must be replaced
by a fixed direct mains connection. At the same time a mains
isolator switch must be fitted.
Attention!
Non-compliance with these warning and safety instructions can
lead to personal injury and material damage.
English / Page 9
5. Important notes for frequency transformer operator
By means of the frequency control the door travel speed in direction OPEN or
CLOSE may be set variably. The approaches for acceleration and deceleration
ensure a soft start and soft stop at the travel limits and thus protect the
mecanical construction of the door.
The frequency of the transformer influences the speed of the operator.
Following sketches show the travel diagrams in OPEN and CLOSE direction by
which the functions of the additional end switches and the activation of the soft
travel are explained.
f [Hz]
t
b open
t
v open
S12
t[s]
OPEN direction
In OPEN direction the frequency transformer accelerates from its basic frequency
in time tb to its travel frequency. The actuation of additional end switch S12
activates the soft stop in OPEN direction, in time tv OPEN it decelerates the
speed to basic frequency. With this speed it travels to the upper end limit.
Fig. 5: OPEN direction
English / Page 10
5. Important notes for frequency transformer operator
f [Hz]
t
v close
t
b open
S14
t[s]
CLOSE direction
In CLOSE direction it accelerates from ist basic frequency in time tb CLOSE to its
travel frequency. If additional end switch S14 is actuated, the soft stop in CLOSE
direction is activated, which decelerates the operator in time tv CLOSE to its
basic frequency. With this speed it travels to the downward travel limit.
Fig. 6: CLOSE direction
English / Page 11
6. Initial operation of control unit Control 45-FU
6.1 Connection control unit – door operator
1. Connect mains lead of the operator to control unit (fig. 7) with the pin-bar
(51) (connect PE-cable to protective terminal (50)).
1. Connect marked system cable to the control signal socket (53) and the
unmarked system cable to the RPM sensor socket (52).
1. Connect mains lead of operator (fig. 8) to pin-bar (54) (guide PE below
printed circuit board and connect it to the protective terminal (57)).
1. Connect marked system cable to the control signal socket (56) and the
unmarked system cable to the RPM sensor socket (55).
Fig. 7: Connections in control unit Control 45-FU
O
51
O
53
O
50
O
52
Fig. 8: Connections in motor with
frequency transformer
Fig. 9: Connections in motor with
frequency transformer
O
55
O
54
O
56
O
57
Connections in control unit:
50. protective terminal
51. mains lead operator
52. RPM sensor socket
53. control signal socket
Connections frequency transformer
in motor:
54. 54. mains lead
55. RPM sensor socket
56. control signal socket
57. protective terminal
English / Page 12
Fig. 9: wiring diagram
6. Initial operation of control unit Control 45-FU
X44
X40
X3
X3a
L N34
PE
PE
PE
X4
X4a
X45
X4b
PE U V W 3 4 X41
S10
S10a S21 S22
L N34
M1
Attention!
The control unit Control 45-FU features a static current circuit.
If this static current circuit is interrupted, power operation of
the door is no longer possible. Elements within this static
current circuit are e.g. the cable slack switch, the wicket door switch and cable
safety switch. If these elements are not available, insert enclosed short-circuit
plug into socket X30.
6.2 Connection control unit — door leaf
Attention!
If you want to put a door system with closing edge safety
device into operation, please pass on according to wiring
diagram mentionned on page 29 insted of wiring diragram
mentionned below. For following operational check the optosensor
(transmitter and receiver) may not be connected.
Legend wiring diagrams:
Connecting terminals:
X3 power unit
X3a FU
X4 operator
X4a primary static current circuit
X4b motor
Plug connections:
X40 RPM sensor operator
X41 RPM sensor motor
X44 control signal operator
X45 control signal FU
English / Page 13
Legend:
Switches (system plugs):
S5 Wicket door switch
S6 Cable slack switch
S7 Night lock
Switches (terminal screw
connections):
S5a * Wicket door switch
S6a * Cable slack switch
S6b * Cable safety device
Plug connections:
X30 Closing edge safety device
(in control unit)
X71A Wicket door contact
X71B Cable slack switch
X71C Night lock
X73 Connection cable
X74 Optosensor transmitter
Terminal blocks:
X2c Static current circuit
(in control unit)
X7C Coiled cable
X7H Static current circuit
X7L Cable slack switch
* If connected, the short-circuit bridge
must be removed
If available
6. Initial operation of control unit Control 45-FU
Connection of cable slack device
• Connect system cable to socket X30 (25) in control unit.
• Insert the control unit mains plug into a site electric socket in accordance with
CEE standard 16 A.
• Check that the power supply at this socket corresponds to the voltage
indicated on the rating plate of the control unit and also that its protection
category complies with the local regulations.
Fig. 10: Wiring diagram
English / Page 14
6. Initial operation of control unit Control 45-FU
• If the control unit is to be connected directly to the mains, a mains isolator
switch will have to be installed.
Operational check
Mains connection and cabling of operator:
• Half open the door by hand.
• Swith ON at the mains.
- The VOLTAGE control light (8) should light up.
-> if not, look up section 'no voltage' in the test instructions.
• Press the OPEN button (11).
- The door should open
-> If the door doesn't move: look up section 'no reaction on IMPULSE' in the
test instructions.
Operational check
Safety circuit:
• Actuate each safety element separately.
- Power operation of the door should now no longer be possible.
- If this is not the case, check the electrical connection of the respective
safety element.
• Disconnect from mains supply.
Attention!
With the following settings it is important to ensure that the
door is never allowed to open or close fully. Halt the door at
least 50 cm before it reaches its mechanical travel limits by
pressing the STOP button (13).
English / Page 15
Fig. 11: Setting of soft stop CLOSE travel limit
6. Initial operation of control unit Control 45-FU
6.3 Adjustment of the control cams
Advice:
For settings of the control cams you need an Allen wrench size
2,5 mm.
6.3.1 Setting of soft stop for CLOSE travel limit
1. Move the door by hand to ist mechanical travel limit DOOR CLOSED.
2. Open housing cover on door operator.
3. Release the stop (grub screw J) of control cam (C).
4. Set control cam (C) in such way, that the limit switch is actuated approx.
0,5 – 0,7 m before the door reaches its CLOSE travel limit (position H).
5. Fix control cam (C) by screwing on grub screw (J).
ABCDEF
C
J
H
G
English / Page 16
Fig. 12: Setting the reference point
6. Initial operation of control unit Control 45-FU
6.3.2 Setting the reference point
1. Move the door by hand to its mechanical travel limit OPEN.
2. Release the stop (grub screw J) of control cam (B).
3. Set control cam (B) in such way, that the reference point switch (G) is actuated
according to fig. D/2 (position H) - approx. 2 angular degrees from switch
point.
4. Fix control cam (B) by screwing on grub screw (J).
ABCDEF
B
J
H
G
English / Page 17
Fig. 13: Setting of soft stop OPEN travel limit.
6. Initial operation of control unit Control 45-FU
6.3.3 Setting of soft stop for OPEN travel limit
1. Release the stop (grub screw J) of control cam (D).
2. Set control cam (D) in such way, that the limit switch is actuated approx. 0,7 –
1 m before the door reaches its OPEN travel limit (position H).
3. Fix control cam (D) by screwing on grub screw (J).
4. Install housing cover again.
5. Connect to power supply and actuate buttom CLOSE (12). The door travels to
its travel limit CLOSE which is set by factory.
ABCDEF
D
J
H
G
English / Page 18
7. Display functions and programming possibilities
7.1 Summary of display functions and programming
possibilities
Display functions
After connecting to mains supply the control unit performs a self-check.
(all control lights light up for approx. 2 sec.).
• See fig. 2, page 5.
Error messages
If control light MALFUNCTION (6) lights up, after shortly pressing button j (10)
the respective error number is indicated (LED's flash irregularly).
The error number is calculated by adding the flashing figures.
• See section 10, error numbers, page 43.
Programming of the operator's basic functions
Press button j (10) longer than 2 sec. The control unit changes from operating
mode to programming mode of basic functions, LED 1 flashes. All other LED's
are glowing. Release button j.
By pressing buttons h (11) or g (12) you can change settings in programming
menu and save with button j. (If button j is actuated without change of
settings by means of buttons h or g, the programming menu is skipped and
the settings remain unchanged.) After last programming menu the programming
of the operator's basic functions is completed, recognizable by all LED's going
out in sequence 8 - 1.
Programming of extended operator functions
Press button j (10) longer than 10 sec. The control unit changes from operating
mode to programming level for extended operator functions, LED 8 flashes
quickly, all other LED's are glowing. Hold button j pressed and select by means
of button h (11) or button g (12) the desired programming level (LED of level
flashes quickly, all other LED's are glowing). Now button j may be released.
The first programming menu of the desired level is selected (LED1 flashes, all
other LED's are glowing). Changes of settings in programming menu are made
by actuating button h or g and can be saved by pressing button j. (If button
j is actuated without change of settings by means of buttons h or g,
English / Page 19
7. Display functions and programming possibilities
the programming menu is skipped and the settings remain unchanged.) After
the last programming menu the programming of the extended operator function
is completed, recognizable by all LED's going out in sequence 8 - 1.
Advice for programming
The programmed data cannot be deleted, they are only overwritten. If the
control unit is in programming mode and neither programming button (h, g, j)
is pressed within 30 sec. the programming is cancelled. The control unit returns
to operating mode. The control light MALFUNCTION (6) flashes, by shortly
pressing button j error number 7 is indicated (= programming cancelled).
English / Page 20
Explanation of the extended operator functions:
7. Display functions and programming possibilities
Programming level
8. level
Operating modes
Table:
see page 23.
3. level
Automatic timer
Table:
see page 24 / 25.
5. level
Operator lighting /
signal lights
Table:
see page 26 / 27.
6. level
Reversion modes
Table:
see page 28.
Functions
- Press and hold OPEN
- Press and hold CLOSE
- Impulse commands
- Direction commands (push
button OPEN or CLOSE)
- Impulse function OPEN
- OPEN time of door
- Warning time
- Warning before start
- Premature closing after
passing photocell.
- Lighting time
- Signal lights
- Lighting
- Photocell OPEN
- Photocell CLOSE
- Closing edge safety device
OPEN
- Closing edge safety device
CLOSE
- Power limit OPEN
- Power limit CLOSE
Explanation
The operator travels after start to travel limit
OPEN.
The operator travels after start to travel limit
CLOSE.
A running operator may be stopped or not
by command.
A running operator may be stopped or not
by command.
Reversion or priority OPEN.
Time, in which the door is open, before
door closes automatically.
Time period, in which signal light flashes,
before door closes automatically.
Time period, in which signal light flashes,
before door starts to move
The door closes either after set open time or
premature after passing photocell.
Lighting time of operator light after door
travel.
The signal lights flash or glow at power
operated movement of the door.
The operator light flashes or glows during
warning time.
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Marantec Control 45 Owner's manual

Category
Garage Door Opener
Type
Owner's manual
This manual is also suitable for

Marantec Control 45 is a control unit for industrial-use operators, providing various functions and safety features for automatic doors. It enables variable speed control, soft starts and stops, and programmable travel limits. Additional functions include inputs for external control elements, photocells, closing edge safety devices, and signal lights, allowing for customized automation and safety solutions. It also features an automatic timer function and a testing option for closing edge safety devices.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI