Expansion module
LGDC Modul EM 185
XW40A
XP14
P1
B
C
D E
F
LG DC MODUL | EM185
XW40B
2 Manual for installation and operation, LGDC Modul EM 185 (#183877 – EN)
Table of contents
1. Safety information ....................................3
1.1 Correct use .....................................3
1.2 Target groups ..................................3
1.3 General safety advice ............................3
2. Scope of delivery .................................... 4
3. Dimensions ......................................... 4
4. Installation .......................................... 4
4.1 Install the expansion module .....................4
4.2 Expansion module wiring .........................5
5. Commissioning .......................................6
6. Care .................................................7
About this document
Original operating manual.
Part of the product.
Reading and subsequent storage mandatory.
Protected by copyright.
No part of this manual may be reproduced without our prior
consent.
Subject to changes which are in the interest of technical
improvements.
All dimensions in millimetres.
Figures are not to scale.
Safety instructions
WARNING!
Safety information regarding a danger that can lead to death or
serious injuries.
CAUTION!
Safety information regarding a danger that can lead to minor or
moderate injuries.
NOTICE
Safety information regarding a danger that can lead to damage or
destruction of the product.
Meaning of symbols
Action prompt
Check
List, itemisation
Reference to other parts of this document
Reference to separate documents that must be observed
) Factory settings
Manual for installation and operation, LGDC Modul EM 185 (#183877 – EN) 3
EN
1. Safety information
WARNING!
Risk of death due to a failure to observe the operating manual!
This manual contains important information for handling the
product safely. Particular reference is made to possible dangers.
Read this manual through carefully.
Follow the safety instructions in this manual.
Store the manual in an accessible location.
1.1 Correct use
The expansion module expands the control of the garage door
drives Comfort 390, Comfort 390 plus and the sectional door drive
VTA.
Use is only permissible:
In dry rooms.
In the private sector.
In technically faultless condition.
Following correct installation.
Any other use is deemed to be improper use.
1.2 Target groups
1.2.1 Operator
The operator is responsible for the building in which the product is
used. The operator has the following tasks:
Knowledge and safekeeping of the instruction manual.
Instruction of all persons who use the door system.
Ensure that the gate system is inspected and maintained
regularly by qualied specialist personnel.
Make sure that inspection and maintenance are documented in
the inspection logbook.
Safe and proper keeping of the inspection logbook.
1.2.2 Specialist personnel
Qualied specialist personnel are responsible for assembly,
commissioning, maintenance, repair, disassembly
and disposal.
Requirements applicable to qualied specialist personnel:
Knowledge of the general and specic safety and accident-
prevention regulations.
Knowledge of the relevant electrical regulations.
Training in the use and care of appropriate safety equipment.
Knowledge of the application of the following standards
EN 12635 (“Doors and gates - Installation and use”),
EN 12453 (“Safety in use of power operated doors -
Requirements”),
EN 12445 (“Gates - Safety in use of power operated gates -
Test methods”).
EN 13241-1 (“Gates - Product standard - Part 1: Products
without re resistance or smoke control characteristics”)
Electrical work by qualied electricians exclusively, in accordance
with DIN VDE 0100.
Requirements applicable to qualied electricians:
Knowledge of the basics of electrical engineering.
Knowledge of national regulations and standards.
Knowledge of the relevant safety regulations.
Knowledge of this operating manual.
1.2.3 Users
Instructed users operate and care for the product.
Requirements applicable to instructed users:
Users are instructed in relation to their work by the operator.
Users must have been instructed on how to use the product
safely.
Knowledge of this operating manual.
Special requirements apply to the following users:
Children aged 8 and above.
Persons with reduced physical, sensory or mental capabilities.
Persons with a lack of experience and knowledge.
These users are only authorised to operate the product.
Special requirements:
The users must be supervised.
Users must have been instructed on how to use the product
safely.
The users must understand the dangers involved in handling
the product.
Children are not allowed to play with the product.
1.3 General safety advice
Persons or objects must never be moved with the aid of the gate.
In the following cases, the manufacturer accepts no liability for
damages. The guarantee on the product and accessory parts is
voided with:
A failure to observe these operating instructions.
Misuse and improper handling.
The assignment of unqualied personnel.
Modications or changes to the product.
The use of spare parts that have not been produced or
approved by the manufacturer.
The product is manufactured according to the directives and
standards mentioned in the Declaration of Incorporation. The
product has left the factory in perfect condition with regard to
safety.
Batteries, accumulators, fuses and bulbs are excluded from
warranty.
Further safety information can be found in the relevant
respective sections of the document.
„4. Installation“
„6. Care“
4 Manual for installation and operation, LGDC Modul EM 185 (#183877 – EN)
2. Scope of delivery
The product is supplied in a range of versions. On the basis of the
table and scope of supply, check which version you have.
Country-specic deviations are possible.
Pos.
1
XW40A
XP14
P1
B
C
D
E
F
LG DC MODUL | EM185
XW40B
1x
2
1x
The adapter provided must be used to connect the cable.
3. Dimensions
3 / 1
126
48
46
XW40A
XP14
P1
B
C
D
E
F
LG DC MODUL | EM185
XW40B
4. Installation
WARNING!
Risk of fatal injuries due to electric shocks!
It is vital that the drive system is disconnected from the
power supply before any wiring work. Ensure that the
electricity supply remains disconnected throughout any
cabling work.
Adhere to the local protection regulations.
Lay the electricity supply cables and control cables; these
MUST be laid separately.
The controls voltage is 12 V DC.
4.1 Install the expansion module
4.1 / 1
XW40A
XP14
P1
B
C
D
E
F
LG DC MODUL | EM185
XW40B
A
B
Fit the expansion module (B) on the mounting rail (A) in the
expansion housing.
Manual for installation and operation, LGDC Modul EM 185 (#183877 – EN) 5
EN
4.2 Expansion module wiring
4.2.1 Overview of module connections
4.2.1 / 1
XW40A
XP14
P1 B C D E F
LG DC MODUL | EM185
XW40B
A
XW40A
XP14
XW40B
B
D
C
A Operating display
Illuminated operation
Flashing cable break
Flashing quickly diagnostic mode
B Light curtain display
C without function
D without function
XP14 Light curtain connection
XW40A Connection of further module
XA40B Connection of further module
4.2.2 Connecting the module
Connecting the operating control and a further module
NOTICE
Possible malfunction of the motor unit!
To guarantee the correct function, only the Marantec bus system
may be connected (MS-Bus).
4.2.2 / 1
XW40A XW40B
XW40A
XP14
P1 B C D E F
LG DC MODUL | EM185
XW40B
Connect the Control vario control unit to the XW40A
connection socket.
If necessary, connect further modules to the XW40B
connection socket.
6 Manual for installation and operation, LGDC Modul EM 185 (#183877 – EN)
Anschluss Light curtain connection (XP14)
4.2.2 / 2 D10246-02
fedc
-X P14
b
P1
BNBN
WHWH
BKBK
RX
TX
BUBU
-BP24A-BP24B
P1 GND
b 12 VDC
c Signal
-XP14 6 pole receptacle
-BP24A Light curtain transmitter
-BP24B Light curtain receiver
5. Commissioning
To ensure correct operation, the light curtain must be connected
before start-up.
5 / 1
XW40A
XP14
P1 B C D E F
LG DC MODUL | EM185
XW40B
A
B
After the control unit has been connected, the display (A) ashes
slowly.
During rst commissioning, the module is automatically identied
by the control after MAINS ON.
If necessary, perform a reset of the MS Bus modules:
Level 1 / menu 8 / G8
The control unit requires approx. 30 seconds to detect connected
modules.
The module reset is ended automatically.
The display (A) lights up green.
The display (B) lights up red.
Further programming is not necessary.
Manual for installation and operation, LGDC Modul EM 185 (#183877 – EN) 7
EN
6. Care
WARNING!
Risk of fatal injuries due to electric shocks!
It is vital that you disconnect the operator system from the
power supply before cleaning. Take measures to ensure that
the power supply remains disconnected for the duration of
the cleaning operation.
NOTICE
Damage resulting from incorrect operation!
When cleaning the drive, never use:
direct water jets, high pressure cleaners, acids or alkaline
solutions.
Clean the outside of the housing using a damp, soft cloth that
does not shed bres.
If particularly dirty, the housing can be cleaned using a mild
detergent.
Type plate
Typ (A) ________________________________________________________________________________________________________
Rev (B) ________________________________________________________________________________________________________
Art. No. (C) ________________________________________________________________________________________________________
Prod. No. (D) ________________________________________________________________________________________________________
Remser Brook 11
DE - 33428 Marienfeld
MADE IN GERMANY
A
BC
D
/
/