Your Installation
Ladder
PAG E
3
Tools Needed
Table of Contents
Mounting Options
PAG E
4
Congratulations on purchasing your new Hunter®
ceiling fan! It will provide comfort and performance in
your home or ofce for many years. This installation and
operation manual contains complete instructions for
installing and operating your fan.
We are proud of our work and appreciate the opportunity
to supply you with the best ceiling fan available
anywhere in the world.
PAG E
21
Maintenance &
Cleaning
Troubleshooting
?
?
?
PAG E
22
Warranty Statement
PAG E
20
PAG E
14
Switch Housing
PAG E
16
No Light Kit Option
PAG E
15
Light Kit Option
PAG E
8
PAG E
11
PAG E
7
Wiring CanopyDownrodPreparation
PAG E
12
Blades
PAG E
13
PAG E
5
Ceiling Bracket
Wall Control
PAG E
18
www.hunterfan.com.br
2
MD517-01 • 10/03/14 • © Hunter Fan Company
What to Expect with Your Installation
w.1 - To reduce the risk of re, electrical shock, or personal injury,
mount fan directly from building structure and/or an outlet
box marked acceptable for fan support of 31.8 kg and use the
mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or
servicing your fan, disconnect the power by turning off the circuit
breakers to the outlet box and associated wall switch location. If
you cannot lock the circuit breakers in the off position, securely
fasten a prominent warning device, such as a tag, to the service
panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage,
use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade
brackets when installing the blade brackets, balancing the blades, or
cleaning the fan. Do not insert foreign objects in between rotating fan
blades.
w.5 - This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
people with a lack of experience and knowledge, unless they have
received instructions regarding the use of the device or under the
supervision of a person responsible for their safety.
w.6 - It is recommended that children be supervised to ensure that
they are not using the appliance improperly
c.1 - All wiring must be in accordance with national and local
electrical codes. If you are unfamiliar with wiring, use a qualied
electrician.
c.2 - Use only Hunter replacement parts.
You may need a
friend to help you.
Check box to see
fan weight
Assess location
0,50 meters
from blade tip to
nearest wall or
obstruction
2,3 meters
from bottom
edge of blade to
the oor
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
WARNINGS
CAUTIONS
Must be able to
secure the fan to
building structure or
fan-rated outlet box.
Do not use a plastic
outlet box.
Select a downrod length
1
2
3
Standard Downrod
for ceilings 2,4 -3 meters high
Shorter Downrod
for fans installed close to ceiling
Longer Downrod
for ceilings 3 meters or higher
Use ONLY Hunter
Ceiling Fan branded
accessory light kits.
www.hunterfan.com.br
Tools Needed
Ladder
Pliers Wire Strippers
Screwdrivers
Power Drill
(optional)
3.5 mm Drill
Bit (optional)
8 mm Drill Bit
(optional)
If mounting to a support structure, you
will also need these tools.
Hammer
(optional)
9 mm Wrench
3
MD517-01 • 10/03/14 • © Hunter Fan Company
4
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Hang your fan by a standard downrod
(included) or use a shorter downrod (sold
separately) for Low-Prole Mounting.
Mounting Options
Note: Do not hang the fan from a
ceiling that is angled greater than 34°
Support
Structure
Ceiling
Outlet Box
(required)
Angled
Mounting
Style
Standard
Mounting
Style
Support
Structure
Ceiling
Outlet Box
(required)
Carefully choose the installation location
that allows for optimal air ow.
The support structure must be able to support 5
times the weight of the fan. The weight of the fan is
located on the product packaging.
You will need a longer downrod (sold
separately) to hang the fan from a
vaulted or angled ceiling.
If you have a at ceiling: If you have an angled ceiling:
5
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Ceiling Bracket
OFF
Refer to warning w.1 on pg. 2
To avoid possible electrical shock, before installing your fan, disconnect
the power by turning off the circuit breakers to the outlet box associated
with the wall switch location.
Turn Power
Remove all four mounting isolators.
Install the ceiling plate gasket onto the
ceiling plate. The four holes in the ceiling
plate should lineup with the four posts in
the gasket.
Tapered
Mounting
Holes
Ceiling
Plate
Gasket
Post
Ceiling
Plate
Ceiling
Plate
Flange
Nuts
Mounting
Isolator
Ceiling
Bracket
Ceiling Plate
Screws
Align the tapered mounting holes in
the ceiling plate with the holes in the
ceiling bracket. Install the four ceiling plate
screws found in the hardware bag and
secure with the ange nuts using an 9 mm
wrench. Hold the ceiling bracket assembly
up to the outlet box and mark the screw
locations. To mount to support structure,
also mark the ceiling for drilling pilot holes.
For angled ceilings, point
opening toward peak.
6
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Ceiling Bracket (continued)
Use wood screws
(included) when securing
to support structure with
approved electrical outlet
box. Drill 3,5 mm pilot
holes in support structure
to aid in securing ceiling
bracket with hardware
found in the hardware
bag.
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg or less.
Note: Do not mount ceiling fan
to a plastic outlet box.
Use concrete anchors (included)
when securing to support structure
with approved outlet box in a concrete
ceiling. Drill 8 mm pilot holes in
support structure. Hammer the M6
expansion anchors into the holes until
the ends are ush with the ceiling.
Install the washer, isolator, and nut
found in the hardware bag to
the expansion anchors.
Use the wood screw to poke holes through
the rubber gasket in order to install the
ceiling bracket assembly to your support
structure or ceiling fan-rated outlet box.
www.hunterfan.com.br
Ceiling Bracket (continued)
Preparation
D
I
S
C
A
R
D
K
E
E
P
!
Remove the shipping blocks from the
motor. Save the screws. They will be
needed for blade iron installation.
Note: Some fans will have a shipping
ring instead of shipping blocks. Please
remove the ring and save the screws.
Time Saver Tip: Get a helper
to insert grommets, found in the
hardware bag, into the blades
while you’re doing the next
couple of steps.
7
MD517-01 • 10/03/14 • © Hunter Fan Company
8
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Downrod
S lide
S lide
1 2 3 4 5
678910
Sold Separately
Longer
Downrod
for angled
ceilings or
ceilings 3 m or
higher
Shorter
Downrod
for fans installed
close to ceiling
Standard
Downrod
for ceilings 2,4-3 m
high
Option 1Option 2
Option 3
skip to next page
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
Steps 6-10 to reassemble with new pipe
Included
(pre-assembled)
Sold Separately
9
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
20 cm
1 cm
C
U
T
&
S
T
R
I
P
(not to scale)
Remove the pre-installed
setscrew so that the downrod
can be inserted.
The wires can be cut,
but leave at least 20 cm
extending from the top of
the downrod.
Downrod (continued)
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
If the setscrew is not tightened
securely, the fan may fall.
K
E
E
P
!
20 cm 1 cm
Insert the downrod through the
adapter cover. Hand tighten the
downrod (at least 4-5 full turns)
until it stops.
10
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Downrod (continued)
DO NOT PICK THE FAN UP BY
THE CANOPY OR WIRES. Place
the downrod ball into the slot in
the ceiling bracket.
Put the wires and downrod
through the canopy. Let
the canopy sit loosely on
top of the fan.
Install the adapter cover.
11
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Wiring
F
R
O
M
F
A
N
Blue
Brown
(Grounded)
Note: To connect the wires,
hold the bare metal leads
together and place a wire
connector over them, then twist
clockwise until tight.
Using the orange wire
connectors from the
hardware bag, connect the
brown wire (ungrounded)
from the ceiling to the
brown and the black with
white stripe wires from the
fan. Connect the blue wire
(grounded) from the ceiling to
the blue wire from the fan.
Using the orange wire
connectors from the
hardware bag, connect the
blue wire (grounded) from
the ceiling to the blue wire
from the fan.
Connect the brown wire
(ungrounded) from the
ceiling to the brown wire
from the fan. Connect the
second (ungrounded)
wire from the ceiling to
the black with white stripe
wire from the fan.
F
R
O
M
F
A
N
Blue
(Ungrounded)
Brown
Black with white stripe
(Grounded)
F
R
O
M
C
E
I
L
I
N
G
(Ungrounded)
For Dual Switches
For a Single Switch
F
R
O
M
C
E
I
L
I
N
G
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
Bl
a
c
k
w
i
t
h
White Stripe
F
R
O
M
F
A
N
F
R
O
M
C
E
I
L
I
N
G
B
R
A
C
K
E
T
Using an orange wire
connector from the
hardware bag, connect
the 4 grounding wires
(green, green/yellow
stripe, or bare copper)
coming from the ceiling,
downrod, fan, and
hanging bracket.
(Grounding)
Green/Yellow
Stripe
Green/Yellow
Stripe
F
R
O
M
C
E
I
L
I
N
G
(Ungrounded)
12
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Canopy
Note: Fan style may vary.
Lift the canopy into place so that
the screw holes are aligned.
Position the canopy so that, when
lifted into place, the canopy ts into
the hanging bracket as shown.
Screw
Holes
Insert the two canopy screws
found in the hardware bag.
13
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Blades
Your blades are shielded with Dust Armor® which
is a nanotechnology coating that repels dust. For
cleaning the fan, use soft brushes or cloths to prevent
scratching. Cleaning agents may damage the nishes.
Remember the screws that
you kept after removing the
shipping blocks (page 7)? You
need them for this step.
Lightly attach the blade irons to the motor with
the blade iron armature screws, then securely
tighten after both screws are attached.
Note: You need six screws to complete this step
Insert grommets, found in the hardware
bag, into the holes in the blades, then
secure each blade to a blade iron with
screws found in the hardware bag.
14
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
housing xture falling.
Switch Housing
Feed the wire plug through the center
hole of the upper switch housing, then
wrap keyhole slots around the screws and
twist counterclockwise.
Align the screw holes in the switch
housing gasket and the motor housing.
Screw two switch housing assembly
screws from the hardware bag halfway
into the motor housing. It does not matter
which two screw holes you choose.
Insert the third screw, found in the
hardware bag, into place and then
tighten all three screws.
15
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Light Kit Option
Connect the plugs from the
upper and lower switch housings.
Make sure to line up the colored
markings on the connectors. Lift the
lower switch housing until its screw
holes are aligned with the screw holes
in the upper switch housing. Install
the three switch housing screws,
found in the hardware bag. Tighten
all three screws.
CONGRATUALTIONS!
YOU’RE DONE!
Carefully lift the globe so the
threaded rod on the light xture
goes through the hole in the
globe. With the other hand,
install the nial cap and nial
onto the threaded rod and
tighten securely.
Install a 20W CFL bulb (sold
separately) into each of the E27
sockets. When necessary, replace
with bulbs of same wattage.
Finial
Finial
Cap
Metal
Plate
Globe
16
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
No Light Kit Option
Remove the light xture from the lower
switch housing by removing the two light
xture assembly screws.
Light Fixture
Assembly
Screw
Lower
Switch
Housing
Light Kit
Cover
Light
Fixture
Disconnect the green with yellow stripe
wires. Disconnect the white wire from the
blue wire. Disconnect the black wire from
the brown wire. Save the wire nuts.
Cap the exposed blue wire, brown wire,
and green with yellow stripe wire with the
previously saved wire nuts.
17
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
CONGRATUALTIONS!
YOU’RE DONE!
No Light Kit Option (continued)
Lift the lower switch housing
until its screw holes are aligned
with the screw holes in the upper
switch housing. Install the three
switch housing screws, found in
the hardware bag. Tighten all
three screws.
Connect the plugs from
the upper and lower switch
housings. Make sure to line up
the colored markings on the
connectors.
Make sure the lower switch housing is securely attached
to the upper switch housing. Failure to properly secure all
three assembly screws could result in the light xture falling.
Using a Phillips Head
screwdriver, install the switch
housing cap to the lower switch
housing using the two switch
housing cap screws.
Switch Housing
Cap Screw
18
www.hunterfan.com.br
MD517-01 • 10/03/14 • © Hunter Fan Company
Press the rotary switch terminal into
the hole in the faceplate as shown
with screw terminals facing away
from the light switch. Install the knob
onto the switch after it is pressed
into the faceplate.
Attach a jumper wire (not included)
from terminal 2 of the rotary switch
to the center terminal of the rocker
switch. Tighten the set screws.
Connect the wires from the capacitor
to the rotary switch terminal as
follows:
Grey from the capacitor to
terminal 3. Tighten the set
screw.
Brown from the capacitor to
terminal 1. Tighten the set
screw.
Green from the capacitor to
terminal 4. Tighten the set
screw.
To install the wall control, you must
first remove the faceplate and switch
assembly from the existing wall control,
if you have one.
Save the screws you removed from
the faceplate to use with the new
included faceplate.
Wall Control
4
1
2
3
Rotary Switch
Terminal
Rotary Switch
Terminal
Capacitor
Knob
4
1
2
3
Rotary Switch
Terminal
Rocker
Switch
Note: A power disconnect switch
should be installed in conjunction
with the wall control.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Hunter Fan 50889 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI