  • Hello! I've reviewed the test report for the ANDOBIL car phone holder model CTVK51. The document details a drop test conforming to the MIL-STD-810H standard. The device successfully passed the test without any visible damage. I'm here to answer any questions you may have about the report or the test.
  • What kind of test was performed on the sample?
    What standard was the drop test compliant to?
    What was the drop height?
    What was the material of the drop plane?
    How many times was the sample dropped?
    What was the result of the drop test?
    What is the product specification of the tested sample?
TEST REPORT
No. :
GZMR220100136601
Date :
Jan 21, 2022
Page:
1
of 5
CUSTOMER NAME:
SHENZHEN ANDOBIL TECHNOLOGY CO., LTD.
RM C1407, BLK C, ZHANTAO TECHNOLOGY BLDG, INTERSECTION
OF GONGYE EAST ROAD AND MINZHI ROAD, XINNIU COMMUNITY,
MINZHI ST, LONGHUA DIST, SHENZHEN, CHINA
Sample Name
:
CAR PHONE HOLDER MOUNT
Product Specification
:
CTVK51
Buyer
:
ANDOBIL
Above information and sample(s) was/were submitted and confirmed by the client. SGS, however,
assumes no responsibility to verify the accuracy, adequacy and completeness of the sample
information provided by client.
*************
SGS Ref. No.
:
GZPH2201000528PS
Date of Receipt
:
Jan 17, 2022
Testing
Start Date :
Jan 17, 2022
Testing
End Date :
Jan 21, 2022
Test result(s)
:
For further details, please refer to the following page(s)
(Unless otherwise stated the results shown in this test report refer only to
the sample(s) tested)
Signed for
SGS-CSTC Standards Technical
Services Co., Ltd. Guangzhou Branch
Testing Center
Gary Bai
Authorized signatory
TEST REPORT
No. :
GZMR220100136601
Date :
Jan 21, 2022
Page:
2
of 5
Summary of Results:
No. Test Item Test Method Result Conclusion
1
Drop Test
With reference to MIL-STD-810H:2019
Method 516.8 Section 4.6.5 (Procedure
IV) and client’s requirement
No visual
damage Pass
Note:
Pass :
Meet the requirements;
Fail : Does not meet the requirements;
/ : Not Apply to the judgment.
Test Sample Description:
Report Sample No. Lab Sample No. Description
A 001 Plastic product
Original Sample Photo
Sample 001(Front) Sample 001 (Back)
TEST REPORT
No. :
GZMR220100136601
Date :
Jan 21, 2022
Page:
3
of 5
Test Item: Drop Test
Test Method: With reference to MIL-STD-810H:2019 Method 516.8 Section 4.6.5 (Procedure IV) and
client’s requirement
Test Condition:
Drop Height: 122cm
Drop Plane: Wood plate
Drop Times: Drop on each face, total 6 drops
Lab Environment Condition: 15~35, 25%RH~75%RH
Test Result:
Sample Results Client’s requirement Conclusion
001 No visual damage No visual damage Pass
Test Photo:
After test-Sample 001(Front) After test-Sample 001 (Back)
TEST REPORT
No. :
GZMR220100136601
Date :
Jan 21, 2022
Page:
4
of 5
During test-Drop face 1 During test-Drop face 2
During test-Drop face 3 During test-Drop face 4
TEST REPORT
No. :
GZMR220100136601
Date :
Jan 21, 2022
Page:
5
of 5
During test-Drop face 5 During test-Drop face 6
Equipment Information:
Equipment Model Equipment No. Calibration date Next Calibration date
Small goods
drop tester GK-SJDL02 GZMR-RL-E126 2021-10-22 2022-10-21