Honeywell GLL Series User manual

Type
User manual

Honeywell GLL Series limit switches are versatile and durable devices that offer precise control and monitoring capabilities in various industrial applications. They feature adjustable lever positioning for flexible actuation and can be mounted with the conduit opening pointed down to prevent moisture accumulation. The switches are designed to withstand harsh environments with IP66/NEMA 1, 12, and 13 ratings, making them suitable for outdoor or washdown applications.

Honeywell GLL Series limit switches are versatile and durable devices that offer precise control and monitoring capabilities in various industrial applications. They feature adjustable lever positioning for flexible actuation and can be mounted with the conduit opening pointed down to prevent moisture accumulation. The switches are designed to withstand harsh environments with IP66/NEMA 1, 12, and 13 ratings, making them suitable for outdoor or washdown applications.

mWARNING
PERSONAL INJURY
Where possible, install these switches with the conduit
opening pointed down to drain moisture away from switch.
Do not install switch at the low point of a conduit run.
Install a fitting into the conduit opening that provides
strain relief to the wires/cable, as well as sealing against
contaminants found in the application.
In applications where fluids or moisture may be present,
seal the fitting threads with a product such as Teflon tape
or pipe dope.
Failure to comply with these instructions could result in
death or serious injury.
GENERAL INFORMATION
1. Refer to page 2 for specifications.
2. Rotate switch head to desired position (90° increments).
Review adjusting instructions below.
3. Mount switch using two M4 or #8 screws (not included).
Torque screws to mounting surface 4,9 Nm to 5,9 Nm
[43.4 in-lb to 52.2 in-lb].
4. All normally closed (NC) contacts are direct opening .
ADJUSTMENT INSTRUCTIONS
To give flexibility in application, the user can perform the
adjustments described below in any order before wiring the
unit.
ACTUATOR HEAD POSITIONING
The actuator head may be positioned in any of four directions.
1. Remove the four head retaining screws while holding
actuator head in place.
2. To prevent actuator spring loss, remove head slowly to
relieve spring tension prior to removal.
3. Rotate actuator head to desired position.
4. Position the large diameter end of the actuator spring
over the actuator. Place retaining screws through gasket
material and position head over screw holes in desired
position.
5. Securely tighten the screws to 0,2 Nm [1.7 in-lb] of torque.
POSITIONING LEVER
The lever on rotary actuated units is adjustable to any of the
segmented positions 360° around the shaft; however, the
degree of rotation is dependant on head position and direction
of roller.
1. Loosen the lever retaining screw with a Phillips head
screwdriver.
2. Remove lever.
3. Reposition lever to desired location.
4. Securely tighten screw.
REVERSING THE ROLLER LEVER
The roller arm may be reversed to face the roller to the inside or
outside of the arm.
ADJUSTABLE LENGTH LEVERS
1. Loosen the levers adjustment screw using a Phillips head
screwdriver.
2. Adjust to desired length.
3. Securely tighten adjustment screw to 1.0 Nm [8.85 in-lb] of
torque.
TOP ROLLER PLUNGER
Switches with top roller plunger must be mounted with plunger
in desired position. Actuating device must not exceed over
travel distance.
WIRING
1. Remove front cover plate screw.
2. Contact block area by terminal screw is labeled for NO
(Normally Open) and NC (Normally Closed) contacts.
3. Connect stranded wire (0,75 mm² - 2,5 mm², 18 AWG14
AWG) or solid wire (0,75 mm² - 1,5 mm², 18 AWG16 AWG)
to desired connector terminals. Use 90°C [194°F] rated wire
when ambient temperature is to exceed 75°C [158°F]:
Torque switch terminal screws to 0,8 Nm to 1,0 Nm
[7.1 in-lb to 8.9 in-lb]
4. Securely tighten cover screw to 0,5 Nm [4.4 in-lb] of torque.
INSTALLATION INSTRUCTIONS FOR THE
MICRO SWITCH LIMIT SWITCH
GLL SERIES
50012101
Issue 6
MICRO SWITCH GLL Series Installation Instructions | sps.honeywell.com/ast | 2
MICRO SWITCH LIMIT SWITCH,
GLL SERIES
Issue 6
50012101
TABLE 1. SPECIFICATIONS
Circuitry 1 NO 1 NC direct opening snap action, slow action (BBM), slow action (MBB); 2NC slow action
Ampere rating 10 A (Thermal)
Supply voltage 300 Vac and 250 Vdc max.
Housing material Plastic
Termination type 12,7 mm [0.5 in] conduit; 20 mm [0.79 in] conduit
Housing type EN 50047
Shock 50 g per PEC 68227c (w/o actuator)
Vibration 10 g per IEC 6826 (w/o actuator)
Sealing IP66, NEMA 1, 12, 13
Approvals cULus, CE, UKCA, CCC
Mechanical life 5 million operations
Operating temperature range 10°C to 80°C [14°F to 176°F]
Figure 1. GLLA**B, GLLC**B Dimensions and
Bar Charts
Snap Action
1NO/1NC
21-22
13-14
21-22
13-14
Slow Action
(Break Before Make)
1NO/1NC
11 12
23 24
Slow Action
(Make Before Break)
1NO/1NC
15-16
15 16
23 24
Slow Action
2NC
21-22
0O
13O
28O
55O
70O
OF
12Ncm
11-12
23-24
0O
15O
30O
40O
75O
OF
5Ncm
23-24
0O
20O
35O
45O
75O
OF
8Ncm
11-12
0O
20O
60O
35O
OF
8Ncm
11
12
21
22
13 14
21 22
Figure 2. GLLA**C, GLLC**C Dimensions and
Bar Charts
Snap Action
1NO/1NC
21-22
13-14
21-22
13-14
Slow Action
(Break Before Make)
1NO/1NC
11 12
23 24
Slow Action
(Make Before Break)
1NO/1NC
15-16
15 16
23 24
Slow Action
2NC
21-22
0
O
13
O
28
O
55
O
70
O
OF
12Ncm
11-12
23-24
0
O
15
O
30
O
40
O
75
O
OF
5Ncm
23-24
0
O
20
O
35
O
45
O
75
O
OF
8Ncm
11-12
0
O
20
O
60
O
35
O
OF
8Ncm
11 12
21 22
13 14
21 22
[0.87]
22
[0.31]
Ø8
[0.49]
12,5
[0.16]
4.0
[0.04]
1,0
[1.20]
30,5
Conduit thread
[2.44]
62
FP OP
[0.31]
8
[0.165]
Ø4,2
[1.22]
31
[0.39]
10
[0.79]
20
[0.63]
16
4,3
[0.169]
Plated
copper
alloy
23
[0.906]
4
[0.16]
8
[0.31]
62
[2.44]
30,5
[1.20]
22
[0.87]
Conduit thread
31
[1.22]
16
[0.63]
20
[0.79]
1
[0.04]
Ø 10
[0.04]
OP
FP
Ø 10
[0.04]
[0.165]
Ø4,2
MICRO SWITCH LIMIT SWITCH,
GLL SERIES
Issue 6
50012101
MICRO SWITCH GLL Series Installation Instructions | sps.honeywell.com/ast | 3
Figure 3. GLLA**D, GLLC**D Dimensions and
Bar Charts
Figure 4. GLLA**F, GLLC**F Dimensions and
Bar Charts
Snap Action
Slow Action
(Break Before Make) Slow Action
Slow Action
(Make Before Break)
1NO/1NC 1NO/1NC 1NO/1NC 2NC
2.5
4.5
6.5
0 mm
10 mm
11-12
23-24
OF
3N
2.5
8.0
0 mm
10 mm
5.5
21-22
13-14
21-22
13-14
OF
8 N
3.0
6.0
0 mm
10 mm
5.0
15-16
23-24
OF
5 N 3.5
5.5
0 mm
8 mm
11-12
21-22
OF
5 N
13 14
21 22
11 12
23 24
11 12
21 22
15 16
23 24
Snap Action
1NO/1NC
1,8
5,5
0 mm
8 mm
3,5
21-22
13-14
21-22
13-14
OF
8 N
13 14
21 22
Slow Action
(Break Before Make)
1NO/1NC
1,5
2,5
4
0 mm
8 mm
11-12
23-24
OF
3N
11 12
23 24
Slow Action
2NC
2,5
4
0 mm
6,5 mm
11-12
21-22
OF
5N
11 12
21 22
Slow Action
(Make Before Break)
1NO/1NC
2
4,5
0 mm
8 mm
3,5
15-16
23-24
OF
5 N
15 16
23 24
FP OP
40,5
[1.59]
8
[0.31]
62
[2.44]
30,5
[1.20]
22
[0.87]
Conduit thread
31
[1.22]
16
[0.63]
105,5
[4.15]
1
[0.04]
22
[0.87]
15 [0.60]
5 [0.197]
24
[0.95]
21
[0.83]
18
[0.71]
10
[0.4]
[0.165]
Ø4,2
11,5 [0.45]
Ø 4,2
[0.165]
OP
4
[0.16]
8
[0.31]
62
[2.44]
30,5
[1.20]
22
[0.87]
Conduit thread
31
[1.22]
16
[0.63]
10
[0.39]
1
[0.04]
FP
31
[1.22]
MICRO SWITCH GLL Series Installation Instructions | sps.honeywell.com/ast | 4
MICRO SWITCH LIMIT SWITCH,
GLL SERIES
Issue 6
50012101
Figure 6. GLLA**A2B, GLLC**A2B Dimensions
and Bar Charts
Snap Action
1NO/1NC
21-22
13-14
21-22
13-14
Slow Action
(Break Before Make)
1NO/1NC
11 12
23 24
Slow Action
(Make Before Break)
1NO/1NC
15-16
15 16
23 24
Slow Action
2NC
21-22
0O
13O
28O
55O
70O
OF
12Ncm
11-12
23-24
0O
15O
30O
40O
75O
OF
5Ncm
23-24
0O
20O
35O
45O
75O
OF
8Ncm
11-12
0O
20O
60O
35O
OF
8Ncm
11 12
21 22
13 14
21 22
41 [1.57]
27
[1.06]
TT
OP
PT
DT
R 20 to 75
[0.79 to 2.95]
Plated
copper
alloy
19,5
[0.77]
4
[0.16]
Ø 17 x 7
[0.67 x 0.28]
8
[0.31]
62
[2.44]
30,5
[1.20]
22
[0.87]
Conduit thread
31
[1.22]
16
[0.63]
20
[0.79]
2
[0.08]
1
[0.04]
[0.165]
Ø4,2
Figure 5. GLLA**A1B, GLLC**A1B Dimensions
and Bar Charts
41 [1.57]
27
[1.06]
TT
OP
PT
DT
R 25
[0.98]
Plated
copper
alloy
19,5
[0.77]
4
[0.16]
Ø 17 x 7
[0.67 x 0.28]
8
[0.31]
62
[2.44]
30,5
[1.20]
22
[0.87]
Conduit thread
31
[1.22]
16
[0.63]
20
[0.79]
1
[0.04]
[0.165]
Ø4,2
MICRO SWITCH LIMIT SWITCH,
GLL SERIES
Issue 6
50012101
MICRO SWITCH GLL Series Installation Instructions | sps.honeywell.com/ast | 5
Figure 7. GLLA**A1Y, GLLC**A1Y Dimensions
and Bar Charts
Snap Action
1NO/1NC
21-22
13-14
21-22
13-14
Slow Action
(Break Before Make)
1NO/1NC
11 12
23 24
Slow Action
(Make Before Break)
1NO/1NC
15-16
15 16
23 24
Slow Action
2NC
21-22
0O
13O
28O
55O
70O
OF
12Ncm
11-12
23-24
0O
15O
30O
40O
75O
OF
5Ncm
23-24
0O
20O
35O
45O
75O
OF
8Ncm
11-12
0O
20O
60O
35O
OF
8Ncm
11 12
21 22
13 14
21 22
42,5 [1.67]
10
[0.4]
TT
OP
PT
DT
Buna
rubber
19,5
[0.77]
4
[0.16]
Ø 50
[1.96]
8
[0.31]
62
[2.44]
30,5
[1.20]
22
[0.87]
Conduit thread
31
[1.22]
16
[0.63]
20
[0.79]
1
[0.04]
31,5
[1.24]
[0.165]
Ø4,2
Figure 8. GLLA**A2Y, GLLC**A2Y
Dimensions and Bar Charts
Snap Action
1NO/1NC
21-22
13-14
21-22
13-14
Slow Action
(Break Before Make)
1NO/1NC
11 12
23 24
Slow Action
(Make Before Break)
1NO/1NC
15-16
15 16
23 24
Slow Action
2NC
21-22
0
O
13
O
28
O
55
O
70
O
OF
12Ncm
11-12
23-24
0
O
15
O
30
O
40
O
75
O
OF
5Ncm
23-24
0O
20O
35O
45O
75O
OF
8Ncm
11-12
0
O
20
O
60
O
35
O
OF
8Ncm
11 12
21 22
13 14
21 22
PT
TT
OP
DT
Ø 50
[1.96]
Buna
rubber
62
[2.44]
Conduit thread
30,5
[1.20]
8
[0.31] 1
[0.04]
19,5
[0.77]
4
[0.16]
20,65
[0.81]
42,5
[1.67]
10
[0.39]
2
[0.08] 20
[0.79]
16
[0.63]
31
[1.22]
[0.165]
Ø4,2
MICRO SWITCH GLL Series Installation Instructions | sps.honeywell.com/ast | 6
MICRO SWITCH LIMIT SWITCH,
GLL SERIES
Issue 6
50012101
Figure 9. GLLA**A4J, GLLC**A4J Dimensions
and Bar Charts
Snap Action
1NO/1NC
21-22
13-14
21-22
13-14
Slow Action
(Break Before Make)
1NO/1NC
11 12
23 24
Slow Action
(Make Before Break)
1NO/1NC
15-16
15 16
23 24
Slow Action
2NC
21-22
0O
13O
28O
55O
70O
OF
12Ncm
11-12
23-24
0O
15O
30O
40O
75O
OF
5Ncm
23-24
0O
20O
35O
45O
75O
OF
8Ncm
11-12
0O
20O
60O
35O
OF
8Ncm
11 12
21 22
13 14
21 22
55 [0.22]
20° - 65°
[0.57] - [5.91]
22 - 150
[0.77]
19,5
22
[0.87]
[1.20]
30,5
[2.44]
62
[0.32]
8
Conduit thread [0.63]
16
[1.22]
31
[0.40]
10,2
[1.34]
34
[0.12]
0.3
[0.04]
1
[0.165]
Ø4,2
500121016EN | 6 | 07/21
© 2021 Honeywell International Inc. All rights reserved.
Honeywell Advanced Sensing Technologies
830 East Arapaho Road
Richardson, TX 75081
sps.honeywell.com/ast
mWARNING
IF USED IN APPLICATIONS
CONCERNING HUMAN
SAFETY
Only use NC direct opening
(“positive opening”/”positive break”)
contacts, identified by the symbol
Do NOT use flexible/adjustable
actuators. Only use actuators
designed for safety applications.
Do NOT defeat, tamper, remove, or
bypass this switch.
Hazardous voltage, disconnect
power before servicing.
Strictly adhere to all installation and
maintenance instructions.
Consult with local safety agencies
and their requirements when
designing a machine-control link,
interface and all control elements
that affect safety.
Failure to comply with these
instructions could result in death or
serious injury.
FOR MORE INFORMATION
Honeywell Sensing and Internet of
Things services its customers through a
worldwide network of sales offices and
distributors. For application assistance,
current specifications, pricing, or the
nearest Authorized Distributor,
visit sps.honeywell.com/ast or call:
USA/Canada +302 613 4491
Latin America +1 305 805 8188
Europe +44 1344 238258
Japan +81 (0) 367307152
Singapore +65 6355 2828
Greater China +86 4006396841
WARRANTY/REMEDY
Honeywell warrants goods of its
manufacture as being free of defective
materials and faulty workmanship
during the applicable warranty period.
Honeywell’s standard product warranty
applies unless agreed to otherwise by
Honeywell in writing; please refer to your
order acknowledgement or consult your
local sales office for specific warranty
details. If warranted goods are returned
to Honeywell during the period of
coverage, Honeywell will repair or replace,
at its option, without charge those items
that Honeywell, in its sole discretion,
finds defective. The foregoing is buyer’s
sole remedy and is in lieu of all other
warranties, expressed or implied,
including those of merchantability
and fitness for a particular purpose.
In no event shall Honeywell be liable
for consequential, special, or indirect
damages.
While Honeywell may provide application
assistance personally, through our
literature and the Honeywell web site, it
is buyers sole responsibility to determine
the suitability of the product in the
application.
Specifications may change without
notice. The information we supply is
believed to be accurate and reliable as of
this writing. However, Honeywell assumes
no responsibility for its use.
MICRO SWITCH LIMIT SWITCH,
GLL SERIES
Issue 6
50012101
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Honeywell GLL Series User manual

Type
User manual

Honeywell GLL Series limit switches are versatile and durable devices that offer precise control and monitoring capabilities in various industrial applications. They feature adjustable lever positioning for flexible actuation and can be mounted with the conduit opening pointed down to prevent moisture accumulation. The switches are designed to withstand harsh environments with IP66/NEMA 1, 12, and 13 ratings, making them suitable for outdoor or washdown applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI