Qlogic SilverStorm 9040 Reference guide

Category
Network switches
Type
Reference guide
D000025-002 Rev. A
SilverStorm 9000
CLI Reference Guide
Page ii D000025-002 Rev. A
S
© 2008 QLogic Corporation. All Rights Reserved Worldwide.
First Published: September 2007
QLogic Corporation, 26650 Aliso Viejo Parkway, Aliso Viejo, CA 92656, (800) 662-4471 or (949) 389-6000
Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no
responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its
use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications
described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no
representation nor warranty that such applications are suitable for the specified use without further testing or
modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
Document Revision History
Revision A, August 30, 2008
Changes Sections Affected
D000025-002 Rev. A Page iii
Table of Contents
1 Introduction
Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
License Agreements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
2 Switch Command Line Interface
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Commands and Functional Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Online Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Keyboard Shortcuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Accessing the CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Groups and Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28
Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39
Subnet Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47
Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-74
Key Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-80
IbSwitchInfo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-82
TimeManagement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-99
SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-103
Capture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-109
3 Virtual I/O Command Line Interface
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Commands and Functional Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Online Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Keyboard Shortcuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Accessing the VIO CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Groups and Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Page iv D000025-002 Rev. A
SilverStorm 9000 CLI Reference Guide
S
Linecard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
Capture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
FibreChannel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Ethernet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-88
D000025-002 Rev. A 1-1
1 Introduction
This manual describes the command line interface (CLI) task information for the
SilverStormâ„¢ 9024 and Silverstom Multi-Protocol Fabric Director (MPFD) family
of switches.
This manual is organized as follows:
Section 1 describes the intended audience and technical support.
Section 2 describes the 9000 switch CLI commands.
Section 3 describes all the Virtual I/O (EVIC and FVIC) CLI commands.
Intended Audience
This manual is intended to provide network administrators and other qualified
personnel a reference for the command line interface of the SilverStorm 9000 series
switches.
License Agreements
Refer to the QLogic Software End User License Agreement for a complete listing
of all license agreements affecting this product.
1 – Introduction
Technical Support
1-2 D000025-002 Rev. A
S
Technical Support
Customers should contact their authorized maintenance provider for technical
support of their QLogic switch products. QLogic-direct customers may contact
QLogic Technical Support; others will be redirected to their authorized
maintenance provider.
Visit the QLogic support Web site listed in Contact Information for the latest
firmware and software updates.
Availability
QLogic Technical Support for products under warranty is available during local
standard working hours excluding QLogic Observed Holidays.
Contact Information
Support Headquarters QLogic Corporation
4601 Dean Lakes Blvd.
Shakopee, MN 55379
USA
QLogic Web Site www.qlogic.com
Technical Support Web Site support.qlogic.com
Technical Support Email support@qlogic.com
Technical Training Email [email protected]
North American Region
Phone +1-952-932-4040
Fax +1 952-687-2504
All other regions of the world
QLogic Support Web Site www.support.qlogic.com
D000025-002 Rev. A 2-1
2 Switch Command Line
Interface
Overview
This section details the usage of the Command Line Interface (CLI) feature for the
SilverStorm 9000 family of switches:
î‚„ The SilverStorm 9024
î‚„ The SilverStorm 9000 Multi-protocol Fabric Director (MPFD) Series:
î‚„ SilverStorm 9020
î‚„ SilverStorm 9040
î‚„ SilverStorm 9080
î‚„ SilverStorm 9120
î‚„ SilverStorm 9240
The CLI allows the user to perform remote configuration and management tasks,
which in many respects mirrors the functionality of the Chassis Viewer GUI.
The CLI is accessed via a terminal attached to the switch spine module(s) RS232
port(s) or via the OOB management port using Telnet and secure shell (SSH). For
a standalone switch, the user would Telnet to the IP address(es) of the unit. Once
connected, the CLI works as any telnet session does.
To access the CLI, a login and password is required. There are two user modes,
operator and administrator with the following access privileges:
Operator:
î‚„ Read only access.
Administrator:
î‚„ Read and write Access.
î‚„ Reboot access.
î‚„ Can change operator and administrator passwords.
2 – Switch Command Line Interface
Commands and Functional Groups
2-2 D000025-002 Rev. A
S
î‚„ Can disable user login and passwords. This would allow all users
admin-level access without the need for a user name or password.
î‚„ Can view all current user sessions
î‚„ Can access all of the commands executed from any open operator
session.
î‚„ Can log out any open user sessions
î‚„ Can send messages to the open user sessions
The CLI allows multiple users to be logged in simultaneously. However, some
commands will be locked to a user(s) if another user is executing the same
command.
The CLI is also accessible through the RS232 serial port of the switch. Accessing
the CLI through the serial port never requires a login and password and defaults to
administrator privileges. Providing access through the serial port means that users
will always have access to the switch, even if Telnet and SSH are not functioning.
Commands and Functional Groups
The list of available commands can be accessed by typing list. To keep the list
short, the commands are grouped into functional groups, which are:
General:
General commands for user management and CLI configuration.
Deprecated:
Commands that have been deprecated.
The Deprecated group contains CLI commands that have been replaced or
are to be removed. Please use the new command where appropriate.
Chassis:
Chassis management commands. (FRU info, fan/power supply state, etc).
Network:
Ethernet interface management commands.
Firmware:
Provides commands for updating the firmware via a File Transfer Protocol
(FTP) server or Secure Copy Protocol (SCP) (if using SSH to access the
Bridge Module). The switch has the ability to store the location of the firmware
files for future upgrades. Additionally, the Firmware functional group includes
commands for viewing the current firmware revisions and for changing the
boot image.
2 – Switch Command Line Interface
Commands and Functional Groups
D000025-002 Rev. A 2-3
A
SubnetManagement:
InfiniBand subnet manager configuration and management.
Log:
Provides commands for viewing log files as well as configuring logging
parameters.
KeyManagement:
License key management.
IbSwitchInfo:
Provides commands for displaying InfiniBand (IB) statistics for all IB ports on
the switch, as well as for configuring port statistic thresholds.
TimeManagement:
Provides commands for retrieving and setting the current system time, as well
as commands for setting the time zone and daylight saving time parameters.
Snmp:
Provides commands for configuring SNMP trap destinations and security
parameters required to access the switch from an SNMP manager.
Capture:
Provides commands for capturing switch-specific information for the purposes
of analysis and debugging.
To list commands within a functional group, simply type in the functional group name.
For example, to list all of the firmware commands, type list Firmware. The system
would display the following:
-> list Firmware
fwUpdateSlot Update units firmware
fwUpdateChassis Update units firmware
fwListFiles List the contents of the firmware ramdisk
fwShowUpdateParams Display firmware default update parameters
fwSetUpdateParams Configure firmware default update parameters
showCapability Display the capabilities/features
showLastScpRetCode Display the return code from the last SCP Firmware Push
fwVersion Display Firmware revisions
bootQuery Query boot image information
bootSelect Change boot selection
2 – Switch Command Line Interface
Online Help
2-4 D000025-002 Rev. A
S
Online Help
The online help for the CLI provides, for each command, all necessary information
to successfully execute the command. For example, typing help list (can also type
list help) displays the following information for the list command:
NAME
list
SYNOPSIS
list [group] [-noprompt] [-verbose]
DESCRIPTION
List available commands.
OPTIONS
group - List the commands in that particular group
-noprompt - Just list the command groups.
-verbose - Print full help for each command, instead of summary.
NOTES
Specify the group name or use 'all' to list all available commands.
Keyboard Shortcuts
î‚„ The CLI keeps a history of recently executed commands. This history is
available via the Up and Down arrow keys.
î‚„ Users may edit the current command with the Left and Right arrow keys.
î‚„ Tab completion: pressing the Tab key after typing at least one character
either completes a command or lists all the available commands that begin
with the characters already typed.
Accessing the CLI
NOTE: The CLI can be accessed via Telnet, SSH, or through the switch RS232
serial port. The following instructions use Telnet.
1. Telnet to the IP address of the switch (the default IP address is 192.168.100.9)
with the following command:
telnet <IP ADDRESS>
2. The system prompts for a username. The CLI has the following default user
names:
Operator access: operator
Administrator access: admin
Type the appropriate username and press Enter.
2 – Switch Command Line Interface
Groups and Commands
D000025-002 Rev. A 2-5
A
3. The system prompts for a password. The CLI has the following default
passwords:
Operator access: operpass
Administrator access: adminpass
Type the appropriate password and press Enter. The system responds with:
Welcome to the <SWITCH> CLI. Type 'list' for the list of
commands.
Groups and Commands
The following section lists all CLI functional groups along with the commands for
each group. Commands for all 9000 switches are listed. Any commands specific to
a switch(es) is noted. For more specific information for each functional group, the
user would execute the help <GROUP NAME> command. For more specific
command information, the user would execute the help <COMMAND NAME>
command.
General
help
Displays help information for a specific command.
Syntax:
Options:
help [command]
[command]
The command to display help for.
2 – Switch Command Line Interface
Groups and Commands
2-6 D000025-002 Rev. A
S
Sample Output:
NOTES: General Help
Type list or ? for the list of commands.
To get help on a particular command type: commandname help.
For convienence purposes you can also type: help commandname
Use the Up and Down arrow keys to browse command history, Left and Right arrow
keys to edit the current command and the Tab key for tab completion of a command.
Two alternate key bindings exist for the backspace and delete keys. If these keys
are not responding as expected use the swapBsDel command to swap the
bindings.
Commands are grouped into subcategories. To list the commands in a subcategory
type in the category heading. Category headings are identified by starting with a
capital letter. For example, to list all the commands that handle log configuration
type Log.
list
Displays a list of all valid commands.
Syntax:
-> help list
NAME
list
SYNOPSIS
list [group] [-noprompt]
DESCRIPTION
List available commands.
OPTIONS
group - List the commands in that particular group
-noprompt - Just list the command groups.
list [group] [-noprompt] [-verbose]
2 – Switch Command Line Interface
Groups and Commands
D000025-002 Rev. A 2-7
A
Options:
Sample Output:
NOTES: Specify the group name or use the option all to list all available commands.
To get a full list of commands and all help text, user list all -verbose.
history
Displays the command history for this session.
Syntax:
Options:
group
Displays a list of commands for a particular group
-noprompt
Displays a list of the command groups only.
-verbose
Print full help for each command, instead of summary.
list
List of Valid Commands:
General General commands for user management and CLI configuration.
Deprecated These commands have been deprecated
Network Snmp configuration commands.
Firmware Update firmware and display current revision levels.
Log Log file display and configuration
IbSwitchInfo InfiniBand port configuration and statistics
TimeManagement Display and configure the system time
Snmp Snmp configuration commands.
Ethernet Provides commands for managing the Ethernet interface.
Type the name of the group you want to list or return to exit:
history
None.
2 – Switch Command Line Interface
Groups and Commands
2-8 D000025-002 Rev. A
S
Sample Output:
reboot
Reboots the device.
Syntax:
Options:
Sample Output:
-> history
command history [30 max lines]:
list
Deprecated
Network
Firmware
Log
IbSwitchInfo
TimeManagement
Snmp
Ethernet
help
list
history
reboot [now][-m][slot n][-s][-n][all]
now
Does not prompt the user before rebooting.
-m
Reboot Master (local) Spine 1 (non-disruptive).
slot n
reset specific device where n = slotNumber (disruptive).
-s
Reboot Slave (remote) Spine 2.
-n
Reboot Slave (remote) management card only (non-disruptive)
all
Reboot All local devices (excludes -n/-m/-s).
-> reboot
Disruptive reboot selected
Proceed with reboot? [N]
2 – Switch Command Line Interface
Groups and Commands
D000025-002 Rev. A 2-9
A
NOTES: You may reboot the local (Master) Spine or the remote (Slave) Spine with
one or multiple arguments.
Non-disruptive arguments will not interfere with switch traffic.
Providing the argument all performs disruptive reboot of all present Spines and
cards.
If rebooting the local device from telnet, ssh, etc., you will have to reconnect after
rebooting.
Default (no arguments) reboots local device disruptively after prompt.
See also: 'resetCard', 'showInventory'.
killCliSession
Terminates an existing CLI session
Syntax:
Options:
Sample Output:
NOTES: This command logs out remote sessions. Use 'who' to obtain the list of
active sessions.
who
Displays currently active CLI sessions.
Syntax:
Options:
killCliSession sessionNumber
sessionNumber
The sessionNumber that is returned from the who command.
-> killCliSession
must supply session number
who
None.
2 – Switch Command Line Interface
Groups and Commands
2-10 D000025-002 Rev. A
S
Sample Output:
NOTES: Displays a list of currently active CLI sessions. Note that a session can
be 'active', but no user information available (in most cases, this indicates the
session is waiting for the user to enter login information).
For each session the following information is displayed:
î‚„ user: username of the logged in user
î‚„ role: security role of the user
î‚„ index: internal session index
î‚„ logged in: timestamp of when the user logged in
î‚„ last cmd: timestamp of the users last command
î‚„ type: method used to connect to the system
î‚„ ip address: ip address of the user (if applicable)
broadcast
Write a message to all active CLI sessions
Syntax:
Options:
Sample Output:
NOTES: Writes the supplied message to all other active CLI sessions. The message
to be written must be encapsulated in quotes, and non-empty.
user role index logged in last cmd type ip address
---------------------------------------------------------------------------------------------------
admin admin 0 13:19:03 07/11/2008 09:41:20 07/11/2008 serial 0.0.0.0
broadcast msg
msg
Message (Note: the message text must be encapsulated in quotes "".
-> broadcast "The system will be rebooted in 5 minutes."
2 – Switch Command Line Interface
Groups and Commands
D000025-002 Rev. A 2-11
A
swapBsDel
Swaps the backspace and delete character key bindings.
Syntax:
Options:
Sample Output:
NOTES: Terminals may bind the backspace and delete key bindings differently.
This command swaps two commonly used bindings, which allow the user to use
the backspace and delete keys properly without having to adjust their terminal
settings. Backspace and delete swapping is persistently maintained per user (i.e.
each login account can have a separate binding).
setTermWidth
Change the terminal width for text formatting purposes.
Syntax:
Options:
Sample Output:
NOTES: Allows modification of the terminal width used for text formatting purposes.
Note that not all commands adhere to this setting. The minimum width is 20
characters.
swapBsDel
None.
-> swapBsDel
setTermWidth width
width
Width of the user’s terminal window. Minimum width is 20 characters.
-> setTermWidth 100
2 – Switch Command Line Interface
Groups and Commands
2-12 D000025-002 Rev. A
S
getTermWidth
Displays the terminal width for text formatting purposes.
Syntax:
Options:
Sample Output:
NOTES: Displays the terminal width used for text formatting purposes. Note that
not all commands adhere to this setting.
prompt
Set the CLI prompt (global for all active CLI sessions).
Syntax:
Options:
Sample Output:
NOTES: This changes the prompt for all CLI sessions. The prompt may not exceed
11 characters and is not saved across reboots. If the prompt contains a space,
asterick, comma, parenthesis or semicolon it must be enclosed with double quotes
". For example: "*a prompt*". Also, if a prompt is not accepted try to enclose it with
double quotes.
getTermWidth
None.
-> getTermWidth
Current terminal width: 80 characters.
prompt str
str
The new prompt.
prompt -> "9024->"
9024->
2 – Switch Command Line Interface
Groups and Commands
D000025-002 Rev. A 2-13
A
case
Display or change the case sensitivity for the command interpreter for the CLI session.
Syntax:
Options:
Sample Output:
NOTES: This displays or changes the case sensitivity for the command interpreter
for the CLI session. If an option is not specified the current case sensitivity is
displayed, otherwise the case sensitivity is turned on or off depending on the
specified option. When case sensitivity is on, the CLI input must match the exact
character case (lower and upper case) as specified in the help text. When case
sensitivity is turned off, the input may be any combination of upper and lower case.
showLastRetCode
Display the return code from the last executed command.
Syntax:
Options:
Sample Output:
NOTES: This allows for automated systems to determine if a command was
successful or not.
case [off | on]
off | on
Turn case sensitivity off or on.
-> case off
Case sensitivity is now off
showLastRetCode [-brief]
-brief
Displays just the numeric value of the return code.
-> showLastRetCode
Last Exit Code: 0: Success
2 – Switch Command Line Interface
Groups and Commands
2-14 D000025-002 Rev. A
S
echo
Echoes text back to the output..
Syntax:
Options:
Sample Output:
NOTES: This echoes the text for each argument back to the output. If there are
multiple arguments they are separated by spaces.
rlogin
Creates I/O terminal to local cards.
Syntax:
Options:
Sample Output:
NOTES: This command allows users to open a terminal to local I/O devices within
the chassis/hemisphere. The command rcmd is an alias of rlogin. See also
hostShow.
echo [<text> ...]
[<text> ...]
Text to be echoed..
MasterSpine1-> echo test
test
rlogin [hostName]
hostName
The name of the device to connect to.
-> rlogin slot2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210

Qlogic SilverStorm 9040 Reference guide

Category
Network switches
Type
Reference guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI