PREFACE
Thank you for purchasing a kipor generator.
This manual covers operation and maintenance of the IG3000E Inverter generator.
All information in this publication is based on the latest product information available at
the time of printing.
Generators produce carbon monoxide, a poisonous, colorless,
odorless gas that can cause death or serious injury.
Indoor use of a generator can kill quickly. Generators should
be used outdoors only
Generators should be used outdoors only and away from
garages and open windows and protected from rain and snow.
Always stop engine before refueling. Wait 5 minutes before
restarting.
We reserve the right to make changes at any time without notice and without incurring
any obligation.
No part of this publication may be reproduced without written permission.
This manual should be considered a permanent part of the generator and should remain
with it if it is resold.
Pay special attention to statements preceded by the following words;
Failure to properly follow these precautions can result in
property damage, serious injury or DEATH!
Read all labels and the owner's manual before operating this
generator.
Keep any source of ignition away from fuel tank, at all times.
The portable generator is not meant to be used as a
permanent back-up power system for the home. A permanently
installed stationary generator is designed to be safely used for
this specific purpose.
Indicates a strong possibility of severe personal injury or death
if instructions are not followed.
Indicates a possibility of personal injury or equipment damage
if instructions are not followed.
NOTE: Gives helpful information.
If a problem should arise, or if you have any questions about the generator, consult an
authorized dealer.
Our generators are designed to give safe and dependable
service if operated according to instructions. Read and
understand the Owner's Manual before operating the gen-
erator. Failure to do so could result in personal injury or
equipment damage.
WARNING
CAUTION
WARNING
WARNING
1. SAFETY INSTRUCTIONS
2. COMPONENT IDENTIFICATION
3. PRE-OPERATION CHECK
4. STARTING THE ENGINE
5. GENERATOR USE
6. STOPPING THE ENGINE
7. MAINTENANCE
8. TRANSPORTING/STORAGE
9. TROUBLESHOOTING
10. SPEIFICATIONS
11. ELECTRICAL WIRING DIAGRAM
12. WARRANTY
CONTENTS
1
3
5
8
10
14
15
19
20
22
23
24
1. SAFETY INSTRUCTIONS
The generators are designed to give safe and dependable
service if operated according to instructions.
Read and understand the Owner's Manual before
operating the generator. Failure to do so could result in
personal injury or equipment damage.
Exhaust gas contains poisonous carbon monoxide. Never
run the generator in an enclosed area.
Be sure to provide adequate ventilation.
The muffler becomes very hot during operation and
remains hot for a while after stopping the engine.
Be careful not to touch the muffler while it is hot.
Let the engine cool before storing the generator indoors.
WARNING
WARNING
WARNING
To ensure safe operation --
Gasoline is extremely flammable and explosive under
certain conditions. Refuel in a well ventilated area with
the engine stopped.
Keep away from cigarette, smoking materials sparks and
other sources of combustion when refueling the
generator. Always refuel in a well-ventilated location.
Wipe up spilled gasoline at once.
Connections for standby power to a building's electrical
system must be made by a qualified electrician and must
comply with all applicable laws and electrical codes.
Improper connections can allow electrical current from
the generator to back feed into the utility lines. Such
back feed may electrocute utility company workers or
others who contact the lines during a power outage, and
when utility power is restored, the generator may
explode, burn, or cause fires in the building's electrical
system.
Always make a pre-operation inspection (page 9) before
you start the engine. You may prevent an accident or
equipment damage.
Place the generator at least three feet or one meter
away from buildings or other equipment during operation.
Operate the generator on a level surface. If the
generator is tilted, fuel spillage may result.
Know how to stop the generator quickly and understand
operation of all the controls. Never permit anyone to
operate the generator without proper instructions.
Keep children and pets away from the generator when it
is in operation.
Keep away from rotating parts while the generator is
running.
The generator is a potential source of electrical shocks
when misused; do not operate with wet hands.
Do not operate the generator in rain or snow and do not
let it get wet.
WARNING
WARNING
WARNING
2. COMPONENT IDENTIFICATION
Fuel meter
Recoil starter grip
Full filler cap Frame
Control panel
Muffler
Spark plug Fuel level indicator
Oil filler Oil drainplug Engine Generator
Air filler
Fuel valve lever
Fig. 1 Outline drawing
2.1 Outline drawing
2.2 Control panel
120V AC receptacle
Overload
indicator light
Smart switch
Grounding terminal
Output indicator reaptacle 12V DC receptacle
Low oil alarm light
Engine switch
Fig. 2 Control panel
3. PRE-OPERATION CHECK
Be sure to check the generator on a level surface
with the engine stopped.
Using nondetergent oil or 2-stroke engine oil could
shorten the engine's service life.
Use a high-detergent, premium quality 4-stroke engine oil, certified to meet or
exceed U.S.automobile manufacturer's requirements for API Service Classification SG,
SF. SAE10W-30 is recommended by us.
Select the appropriate viscosity for the average temperature in your area.
3.1 Check the engine oil level
Remove the oil filler cap, and wipe the dipstick with a clean rag. Check the oil level by
inserting the dipstick in the filler hole without screwing it in. (See Fig.3)
The engine may be damaged while running it at low oil level.
The Low Oil Alarm System will automatically stop the
engine before the oil level falls below the safe limit.
However, to avoid the inconvenience of an unexpected
shutdown, it is still advisable to visually inspect the oil
level regularly.
3.2 Check the fuel level.
If the fuel level is low, refuel the fuel tank until the level as specified.
After refueling, tighten the fuel filler cap seurely.
Use unleaded 87 octane regular grade gasoline.
Unleaded gasoline produces fewer engine and spark plug deposits and extends
exhaust system life.
CAUTION
NOTE
NOTE
SAE Viscosity Grades
-20- -10 0 10 20 30 40
0 20 40 60 80 100 F
Ambient Temperature
Single
viscosity
Multi-
viscosity
Never use an oil/gasoline mixture or dirty gasoline. Avoid
getting dirt, dust or water in the fuel tank.
Gasoline is extremely flammable and is explosive under
certain conditions.
Refuel in a well-ventilated area with the engine stopped.
Do not smoke or allow flames or sparks in the area where
the engine is refueled or where gasoline is stored.
Do not overfill the fuel tank (there should be no fuel above
the upper limit mark). After refueling, make sure the tank
cap is closed properly and securely.
Be careful not to spill fuel when refueling. Spilled fuel or
fuel vapor may ignite, If any fuel is spilled, make sure the
area is dry before starting the engine.
Avoid repeated or prolonged contact with skin or
breathing of vapors. KEEP OUT OF REACH OF
CHILDREN.
WARNING
Oil filler cap
Dipstick
Oil filler hole
Oil drain hole
Upper limit
Lower limit
Fig.3 Oil level diagram
Fuel tank capacity: 2.5 gallons 9.5L
GASOLINES CONTAINING ALTERNATE FUELS
If you decide to use a gasoline containing ethanol or methanol, be sure its octane
rating is no lower than the specification. Do not use a blend that contains more than
15% ethanol. Do not use gasoline containing methanol that does not also contain co-
solvents and corrosion inhibitors for methanol. Never use gasoline containing more
than 5% methanol, even if with co-solvents and corrosion inhibitors.
Fuel system damage or engine performance problems
resulting from the use of fuels that contain alcohol is
not covered under the warranty. We cannot en-dorse
the use of fuels containing methanol since evidence of
their suitability is as yet incomplete.
Before buying fuel from an unfamiliar station, try to find
out if the fuel contains alcohol, if it does, confirm the
type and percentage of alcohol used. If you notice any
undersirable operating symptoms while using a
gasoline that contains alcohol, or one that you think
contains alcohol, replace it by a gasoline that you
know does not contain alcohol.
3.3 Check the air cleaner.
Check the air cleaner element to be sure it is clean and in good condition.
Never run the engine without the air cleaner. Rapid
engine wear will result from contaminants, such as dust
and dirt, being drawn through the carburetor, into the
engine.
Unsnap the two clips, remove the element from the air cleaner cover and check it for
cleanliness, or replace the element if the paper is dirty or torn or the rubber frame is
brittle or distorted. (See Fig.4)
NOTE
CAUTION
Foam element
Air cleaner cover
Clips
Fig. 4 Remove air cleaner
WARNING
4. START ENGINE
If you start the generator set in case of first fueling, long time storage or fuel exhaust,
please turn the fuel valve handle to "ON" position, and start the generator after 10 to
20 seconds. The fuel valve handle is at the rear side of the oil tank. (Refer to picture 1)
Disconnect load from AC receptacle before starting the engine.
Check whether the starting battery is equipped, if it is equipped, please operate
according to 4.1, otherwise, please operate according to 4.2.
4.1 Electric starter
4.1.1 Turn the fuel valve handle to "ON" position. (Refer to Fig. 5)
4.1.2 Pull out the choke valve handle, and close the choke valve. (Refer to 5)
4.1.3 Turn the engine switch to "START" position to start the engine. (Refer to 6)
Fig.
Fig.
Pull out the chock valve
handle to close the
chock valve.
Fig. 5 Turn the fuel valve handle to the "ON" position; pull out the chock
valve handle to close the chock valve.
Turn the fuel valve handle to "ON" position.
Engine switch Engine switch
The engine switch automatically
returns to the "RUN" position after starting
Fig.7
Fig.6 Turn the engine switch to
"START" position to start the engine
4.1.4 Loosen the engine switch after starting, and it will return to the "RUN" position
automatically. (Refer to Fig. 7)
4.1.5 Push the choke valve handle after preheating, and start the choke valve.
4.2 Recoil starter
4.2.1 Refer to 4.1.1
4.2.2 Refer to 4.1.2
4.2.3 Pull the starting handle slightly until you feel pressure, then pull out the starting
handle quickly according to the arrow direction in the picture. (Refer to Fig. 8)
4.2.4 Refer to 4.1.5
5. GENERATOR USE
To prevent electrical shock from faulty appliances, the
generator should be grounded. Connect a length of
heavy wire between the generator's ground teminal and
an external ground source.
Do not exceed the current limit specified for any one
receptacle.
Do not connect the generator to a household circuit.
This could cause the damage to the generator or to
electrical appliances in the house.
Do not modify or use the generator for other purpose
than it is intended for. Also observe the following when
using the generator.
Do not connect generators in parallel.
Do not connect an extension to exhaust pipe.
When an extension cable is required, be sure to use a
rubber sheathed flexible cable.
Limit length of extension cables; 60m for cables of
22
1.5mm and 100m for cables of 2.5mm .
Keep the generator away from other electric cables or
wires such as commercial power supply lines.
The DC receptacle can be used while the AC power is
in use. If you use both at the same time, be sure not to
exceed the total power for AC and DC.
Most appliance motors require more than their rated
wattage for start-up.
WARNING
CAUTION
AC applications
1. Start the engine and make sure the output indicator light (green) comes on.
2.Confirm that the appliance to be used is switched off, and plug in the appliance.
NOTE
High altitude operation
At high altitude, the standard carburetor air-fuel mixture will be excessively rich.
Performance will decrease, and fuel consumption will increase.
High altitude performance can be improved by installing a smaller diameter main fuel
jet in the carburetor and readjusting the pilot screws. If you always operate the
generator at altitudes higher than 5,000 feet (1500M) above sea level, have your
authorized KIPOR dealer perform these carburetor modifications.
Even with suitable carburetor jetting, engine horsepower will decrease approximately
3.5% for each 1000 feet (300M ) increase in altitude. The affect of altitude on the
horsepower will be greater than this if no carburetor modification is made.
Operation of the generator at an altitude lower than the
carburetor is jetted for may result in reduced
performance, overheating, and serious engine damage
caused by an excessively lean air/fuel mixture.
CAUTION
Fig. 8 Starter grip
Starter grip
To prevent the possibility of creating a spark near the
battery, connect charging cable first to the generator,
then to the battery. Disconnect cable first at the battery.
Before connecting charging cables to a battery that is
installed in a vehicle, disconnect the vehicles grounded
battery cable. Reconnect the vehicle's grounded
battery cable after the charging cables are removed.
This procedure will prevent the possibility of a short
circuit and sparks if you make accidental contact
between a battery terminal and the vehicle's frame or
body.
Do not attempt to start an automobile engine with the
generator still connected to the battery. The generator
may be damaged.
Connect the positive battery terminal to the positive
charging cord. Do not re-verse the charging cables, or
serious damage to the generator and/or battery may
occur.
The battery gives off explosive gases; keep spark,
flames and cigarettes away. Provide adequate
ventilation when charging.
The battery contains sulfuric acid (electrolyte). Contact
with skin or eyes may cause severe burns. Wear
protective clothing and a face shield.
-If electrolyte gets on your skin, flush with water.
-If electrolyte gets in your eyes, flush with water for at
least 15 minutes and call a physician.
Electrolyte is poisonous.
-If swallowed, drink large quantities of water or milk
and follow with milk of magnesia or vegetable oil and
call a physician.
KEEP OUT OF REACH OF CHILDREN.
WARNING
CAUTION
WARNING
--
Substantial overloading that continuously lights the
overload indicator light (red) may damage the
generator. Marginal overloading that temporarily lights
the overload indicator light (red) may shorten the
service life of the generator.
Be sure that all appliances are in good working order
before connecting them to the generator. If an
appliance begins to operate abnormally, becomes
sluggish, or stops suddenly, turn off the generator
engine switch immediately. Then disconnect the
appliance, and examine it for signs of malfunction.
If an overloaded circuit trips the AC circuit breaker,
reduce the electrical load on the circuit, and wait a few
minutes before resuming operation.
Output Indicators
The output indicator light(green) will remain ON during normal operating conditions.
If there is a short circuit or overloaded circuit in a connected appliance the output
indicator light (green) blinks and current to the connected appliance (s) will shut off.
When this happens disconnect the appliance (s) and stop the engine to investigate the
problem.
Determine if the cause is a short circuit or overloaded circuit in a connected appliance.
Correct the problem and restart the engine.
If the output indicator light (green) may blink again, consult your generator dealer.
The output indicator light (green) may blink at intervals of 2.5 seconds depending on
connected appliance (s) to the AC receptacles. It indicates that the output voltage has
dropped slightly. it does not matter as long as the connected appliances work properly.
DC application
The DC receptacle may be used for charging 12 volt automotive or marine batteries
only.
1. Connect the charging cables to the DC receptacle of the generator and then to the
battery terminals.
CAUTION
NOTE
--
6. STOPPING THE ENGINE
To stop the engine in an emergency, turn the engine switch to the OFF position.
IN NORMAL USE:
1. Turn the engine switch to the OFF position.
2. Switch off the connected equipment and pull the inserted plug.
3.Turn the fuel valve lever to the OFF position.
Be sure both the fuel cap vent lever and the engine
switch are in "OFF" position when stopping,
transporting and/or storing the generator.
CAUTION
7. MAINTENANCE
NOTE: (1) Log hours of operation to determine proper maintenance.
(2) Service more frequently when used in dusty areas.
(3) These items should be serviced by an authorized dealer, unless the owner has the proper tools
and is mechanically proficient. See the Shop Manual.
ITEM
Perform at every indicated month
or operating hour interval, which-
ever comes first.
REGULAR SERVICE PERIOD(1)
Fuel line Check
Check level
Change
Check
Clean
Clean-adjust
Clean
Check-adjust
Clean
Engine oil
Air cleaner
Spark plug
Sediment cup
Valve clearance
Fuel tank and filter
EVERY
YEAR
OR
200 HRS
EACH
USE
FIRST
MONTH
OR
20HRS
EVERY 3
MONTHS
OR
50HRS
EVERY 6
MONTHS
OR
100 HRS
(2)
(3)
Every 2 years (Replace if necessary) (2)
Maintenance Schedule
CAUTION
WARNING
(3)
The purpose of the maintenance and adjustment schedule is to keep the generator in
the best operating condition.
Inspect or service as scheduled in the table below.
Shut off the engine before performing any maintenance. If
the engine must be run, make sure the area is well
ventilated. The exhaust contains poisonous carbon
monoxide gas.
Use genuine our parts or their equivalent. The use of
replacement parts which are not of equivalent quality
may damage the generator.
2. Start the engine
The DC receptacle may be used while the AC power is
in use.
An overloaded DC circuit will trip the DC circuit
protector. If this happens, wait a few minutes before
pushing in the circuit protector to resume operation.
Low oil alarm system
The low oil alarm system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls
below a safe limit, the low oil alarm system will automatically shut down the engine(the
engine switch will remain in the ON position).
If the low oil alarm system shuts down the engine, the low oil alarm indicator light(red)
will come on when you operate the starter, and the engine will not run. If this occurs,
add engine oil.
NOTE
1. CHANGING OIL
Drain the oil the engine is still warm to assure rapid and complete draining.
(1) Remove the oil filler cap and oil drain plug to drain the oil.
(2) Install the oil drain plug, and tighten it securely.
(3) Refill with the recommended oil, and check the oil level.
(4) Reinstall the oil filler cap and tighten it securely.
Engine oil capacity: 0.6L
Wash your hands with soap and water after handling used oil.
Please dispose of used motor oil in a manner that
is compatible with the environment. We suggest
you take it in a sealed container to your local
service station for reclamation. Do not throw it in
the trash or pour it on the ground.
2. AIR CLEANER SERVICE
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor
malfunction, service the air cleaner regularly. Service more frequently when
operating the generator in extremely dusty areas.
Do not use gasoline or low flash point solvents for
cleaning. They are flammable and explosive under
certain conditions.
Never run the generator without the air cleaner.
Rapid engine wear may result.
(1) Unsnap the clips, remove the air cleaner cover.
(2) If the paper element is dirty, replace it with a new one. Do not clean the paper
element. If the rubber housing is brittle or distorted or the element does not
completely seal inside the cover, replace the element.
(3) Reinstall the air cleaner cover.
NOTE
WARNING
CAUTION
3. FUEL SEDIMENT CUP SERVICE
Gasoline is extremely flammable and explosive
under certain conditions. Do not smoke or allow
flames or sparks in the area.
The filter prevents dirt or water which may be in the fuel tank from entering the
carburetor. If the engine has not been run for a long time, the filter should be
cleaned.
(1) Turn the fuel valve lever to the OFF position.
(2) Remove the sediment cup by turning it counterclockwise.
(3) Clean the cup and filter thoroughly.
(4) Reassemble. Do not damage the O-ring.
After installing the sediment cup, be sure to tighter
it securely. Check for fuel leaks and make sure the
area is dry before starting the engine.
4. SPARK PLUG SERVICE (See Fig 7)
RECOMMENDED SPARK PLUG: F6RTC
To ensure proper engine operation, the spark plug must be properly gapped and
free of deposits.
(1) Remove the spark plug cap.
(2) Clean any dirt from around the spark plug base.
3. Use a spark plug wrench to remove the spark plug.
4. Visually inspect the plug. Discard it if the insulator is cracked or chipped.
Clean the spark plug with a wire brush if it is to be reused.
5. Measure the plug gap with a feeler gauge.
The gap should be 0.70-0.80mm (0.028-0.031in). Correct as necessary by
carefully bending the side electrode. (See Fig8)
6. Install the spark plug carefully, by hand, to avoid cross-threading.
7. After a new spark plug has been seated by hand ,it should be tightened 1/2turn
8. Reinstall the spark plug cap on the spark plug securely.
WARNING
WARNING
The spark plug must be securely tightened. An
improperly tightened plug can become very hot and
possibly damage the generator.
Never use a spark plug with an improper heat
range.
NOTE
Fig. 9 Remove the spark plug
0.7-0.8mm
(0.028-0.031in)
Spark plug wrench Spark plug cover
Handle
Spark plug gap
Fig.10 Check spark plug clearance
8. TRANSPORTING / STORAGE
8.1 When transporting the generator, turn the fuel valve lever OFF and keep the
generator level to prevent fuel spillage. Fuel vapors or spilled fuel may ignite.
8.2 Extended Storage:
1. Be sure the storage area is free of exc-
essive humidity and dust.
2. Drain the fuel
a. Open the left side maintenance cover.
b. Turn fuel valve lever to ON and then
loosen the carburetor drain screw. Drain
the gasoline from the carburetor and fuel
tank into a suitable container.
c.Tighten the carburetor screw, close the fuel valve lever and left side
maintenance cover.
3. Once a month, recharge the battery.
4. Change the engine oil.
5. Remove the spark plug and pour a tablespoon of clean engine oil into the
cylinder. Crank the engine several revolutions to distribute the oil, then reinstall
the spark plug.
6. Slowly pull the starter grip until resistance is felt. At this point, the piston is
coming up on its compression stroke and both the intake and exhaust valves are
closed.
Storing the engine in this position will help protect it from internal corrosion.
8.3 Exercising the Generator:
Any small engine is very susceptible to fuel varnishing. Gasoline fuel systems
have very small orifices and passageways which can easily become clogged by
fuel residue. This can lead to hard starting and rough running.
Fuel preservatives are readily available at leading RV and marine dealers.
Regularly add a fuel preservative and exercise the generator by running it at a
50% load for 60 minutes every month. This will also help remove moisture from
the alternator windings.
Drain the carburetor bowl prior to any storage period longer than 30 days.
Drain
plug
9. TROUBLESHOOTING
When the engine will not start:
Is there fuel in the tank?
NO
Refuel the fuel tank
YES
If the starting knob is on the "ON" position
Turn it to the "ON" position
Is the enough oil in the engine? Add the recommended oil.
Is there a spark from
the spark plug?
Replace the
spark plug.
Still no
spark
YES
YES
NO
NO
NO
If the fuel valve open? Open the fuel valve
YES
NO
Take the generator
to an authorized dealer
To check:
1. Remove the spark plug cap and clean any
dirt from around the spark plug.
2. Remove the spark plug and install the
spark plug in the plug cap.
3. Set the plug side electrode on the cylinder
head bolt to ground.
4. Pull the recoil starter; sparks should jump
across the gap.
To check:
1. Turn off the fuel valve and remove the drain
screw.
2. Turn on the fuel valve. Fuel should flow the
fuel tank.
Be sure there is no spilled
fuel around the spark plug.
Spilled fuel may ignite.
If the engine still does not start,
take the generator to an
authorized dealer.
WARNING
Is the fuel reaching the carburetor?
No electricity at the DC receptacle:
Appliance does not operate:
Is the output indicator light ON?
Is the overload in-
dicator light ON?
Take the generator to an
authorized dealer.
Check the electricity
equipment
Take the generator to an
authorized dealer.
Take the generator to an
authorized dealer.
Turn the DC circuit protector on.
Is DC circuit protect on?
NO
YES
YES
NO
NO
NO
Light ON
YES
Change electrical equipment
Repair the electrical equipment
10. SPECIFICATIONS
Model
Type
Rated Voltage
Frequency
Maximum Output
Rated Output
DC Output
Engine Model
Engine Type
Displacement
Compression Ratio
Engine Speed
Cooling System
Ignition System
Oil Capacity
Fuel Tank Capacity
Rated Load Run Time
Noise Level- no load-full load @ 23' (7m)
Spark Plug
Length
Width
Height
Weight
Inverter
120
60 HZ
3000W, 25A
2800W, 23.3A
KG205
4 stroke, overhead valve, single cylinder
12.0 cu in (196 cc)
8.5:1
3600 rpm with smart throttle off
Forced Air
Transistorized
.57 qt (0.6L)
2.5 gal (9.5 L)
5.6 hrs
70-74 dB
F6RTC
15.75 in (400 mm)
19.3 in (490 mm)
16.9 (430 mm)
77 lbs (35 kg)
11. ELECTRICAL WIRING DIAGRAM
--
DC Receptacle
Charging
winding
Blue
Blue
Blue
Blue
Rectify Bridge
Red
Black
Red
Black
Green
Green
Black
White
Brown
Gray Yellow/Green
Inverter
Yellow
Orange
Blue
Pink
Stepping motor
Smart Switch
Red
Red
Black
Main winding
White
White
Sub winding
Black
White
Brown
Gray
Red
Green
Yellow
Orange
Blue
Yellow/Green
Red
Green
Yellow/Green
Yellow
Orange
Blue
Yellow/Green
Spark plug
Low oil Switch
Green
Signal phase receptacle
Working indication
Overload indication
Low oil indication
High-pressure package
Ignition winding
Trigger winding
Black
Black
Stepping motor
Choke
valve
controller
Temperature sensor
Electric door lock
Starting motor
DC contactor
Red
Black
Yellow
Blue
Winding
Charging
adjuster
Flameout
Purple
Purple
IG3000E
--
LENGTH OF WARRANTY:
Generators and/or batteries that are supplied with applicable products as standard, original
equipment are covered by this warranty from the date of original retail purchase for a period of 2
years for residential use and 1 year for commercial applications. Units used in rental fleets or as
demonstration models will be considered commercial usage. The warranty coverage is continual from
the original date of purchase, and does not restart upon the replacement of any part or complete unit.
Individual parts replaced at any point during the warranty period are only eligible for warranty
coverage for the balance of the original warranty period.
ELIGIBILITY:
To be eligible for warranty service, the product must be purchased in North America from an
authorized Kipor dealer. This warranty applies to the original retail purchaser only, and is not
transferable. Proof of purchase is required. Goods exported from North America as well as goods
sold at auction are excluded from warranty coverage.
COVERAGE:
Parts, labor and regular shipping costs will be covered by Coast Distribution for any failure that is
proven to be a failure in material or workmanship under normal use during the applicable warranty
time period. Coast Distribution reserves the right to repair or replace these parts at its option. Coast
Distribution may request defective parts to be returned. Anything replaced under warranty becomes
the property of Coast Distribution.
TO OBTAIN WARRANTY SERVICE:
Contact any authorized dealer or contact our national customer service center at:
Phone 1-877-544-4449
Fax 1-800-263-0280
If contacting us by fax or e-mail, be sure to include a description of the problem as well as all return
contact info such as address, phone number, fax number, e-mail, etc. Engine serial number and proof
of purchase is required.
EXCLUSIONS:
THIS WARRANTY DOES NOT EXTEND TO PARTS AFFECTED OR DAMAGED BY ACCIDENT
AND/OR COLLISION, NORMAL WEAR, FUEL CONTAMINATION, USE IN AN APPLICATION FOR
WHICH THE PRODUCT WAS NOT DESIGNED OR ANY OTHER MISUSE, NEGLECT,
INCORPORATION OR USE OF UNSUITABLE ATTACHMENTS OR PARTS, UNAUTHORIZED
ALTERATION, OR ANY CAUSES OTHER THAN DEFECTS IN MATERIAL OR WORKMANSHIP OF
THE PRODUCT. THIS WARRANTY DOES NOT EXTEND TO NORMAL MAINTENANCE ITEMS
SUCH AS SPARK PLUGS AND FILTERS.
DISCLAIMER OF CONSEQUENTIAL DAMAGE AND LIMITATION OF IMPLIED WARRANTIES:
COAST DISTRIBUTION DENIES ANY RESPONSIBILITY FOR LOSS OF TIME OR USE OF THE
PRODUCT, TRANSPORTATION, COMMERCIAL LOSS, OR ANY OTHER INCIDENTAL OR
CONSEQUENTIAL DAMAGE. ANY IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF
THIS WRITTEN LIMITED WARRANTY.
Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the
exclusion or limitation of incidental or consequential damages. Therefore, the above exclusions and
limitations may not apply to you. This warranty gives you specific legal rights, and you may also have
other rights which vary from state to state.
Limited Warranty
Kipor Power Equipment
12. WARRANTY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Kipor IG3000E User manual

Category
Power generators
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI