IHP.US.com
127274-01B 3
Figure 7 - Apply Conversion Labels over Existing Certification
Label on Lighting Instruction Plate
VENTED GAS FIREPLACE
Conversion Kit Model
Type of Gas
Previous Model #
PFS
®
Figure 8 - Print Previous Model Number on
Conversion Label
Figure 9 - Conversion Information Label
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact INNOVATIVE HEARTH PRODUCTS at
1-800-655-2008. When calling please have your model and serial
numbers of your heater ready.
You can also visit our web site at
www.IHP.US.com.
CONVERSION LABELING AND PLACEMENT
1. Apply conversion label over top of existing certification label
(see Figure 8). Existing certification label is located on lighting
instructions plate inside gas valve compartment area. With
permanent ink, print previous model number on label in space
provided (see Figure 8).
2. After filling data required on conversion information label (see
Figure 9), affix it to floor of appliance where it is easily seen
when bottom access door is removed.
Lighting Instruction Plate
Conversion Label
FINAL PREPARATION
1. Leak check gas control and any connections you've
made before operating appliance. Refer to Checking Gas
Connections in owner's manual.
2. Reinstall glass door and close latches.
3. Replace screen and reinstall bottom access door.
The conversion is now complete.
To operate your fireplace, refer to Operating Fireplace in your appli-
ance owners manual.
WARNING: Test all gas piping and connections,
internal and external to unit, for leaks after installing
or servicing. Correct leaks at once.
WARNING: Never use an open flame to check for
a leak. Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak. Correct all
leaks at once.
WARNING: This conversion kit shall be installed
be a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes
and requirements of the authority having jurisdiction.
If the information in these instruction is not followed
exactly, a fire, explosion or production of carbon mon-
oxide may result causing property damage, personal
injury or loss of life. The qualified service agency
is responsible for the proper installation of this kit.
The installation is not proper and complete until the
operation of the converted appliance is checked as
specified in the manufacturer's instructions supplied
with the kit.
CONVERSION INFORMATION LABEL
This appliance was converted on
___ - ___ - ___ to ______________ gas
with Kit No. _______________________
by _____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
(name and address of organization making
this conversion), which accepts the
responsibility that this conversion has been
properly made.
106080-01
Day Month Year