BLOOMFIELD INDUSTRIES
2 ERIK CIRCLE, P. O. Box 280
Verdi, NV 89439
telephone: 888-492-2782
fax: 888-492-2783
www.wellsbloomfield.com
CONVERSION INSTRUCTION
Convert Model 9465 KFT to
Mechanical Switches
CAUTION
ELECTRIC SHOCK HAZARD
Disconnect appliance from electric
power before beginning this
conversion.
IMPORTANT:
This procedure must be performed by
factory authorized personnel. All wiring
terminal attachment must be performed
in accordance with the wire terminal
manufacturer’s specifications using
correct tooling.
727
p/n 87439A Rev. (-) ECN-12956 I727 051114 cps
Page 1 of 4
KIT # 87439 - Convert Model 9465KFT Electronic Portion
Control to Mechanical Switches with Portion Control
1. Disconnect unit from electric power.
2. Remove portion control assembly from front of unit.
3. Refer to 9465KFT Wiring Diagram, page 2. Mark wires to
control board, then disconnect wires from board. Discard
old board.
4. Unfasten contactor from mounting bracket. Remove and
discard old bracket. Install new bracket and remount
contactor. Mount portion control board to new bracket.
5. Locate red wire #12 and blue wire #13. Determine a
position on each wire that will comfortably reach the
portion control board.
Cut wire #12 at the determined
location, strip insulation and
crimp a provided female terminal
(small barrel) to each wire.
Connect to L2 and VALVE
COMM on portion control
board.
Cut wire #13 at the determined
location, strip insulation, twist
both wires together and crimp on
provided female terminal ( large
barrel). Connect to L1 on portion
control board.
6. Locate 2 ea. blue wires #14 near
front of unit and remove tape
from terminals.
7. Connect provided wiring harness
to switch panel and portion
control board.
8. Refer to revised 9465 Wiring
Diagram, page 3. Connect
existing wires to new switch
panel and portion control
board per diagram.
9. Assemble switch panel to unit.
Connect unit to electric power
and test for proper operation.
10. Program portion control
option as required.
(see page 4)
52
51
54
53
56
55
RED
RED
BRO
W
N
BROW
N
BLUE
BLUE
NUT 10-32 KEPS 4 places
SPACER 4 places
CONTACTOR
BRACKET
SWITCH PANEL
55
53
51
56
54
52
32
23
33
RED
RED
BRO
W
N
BROW
N
BLUE
BLUE
RED
RED
BLUE
BLU
E
R
ED
BRO
W
N
BLUE
PORTION CONTROL BOARD
12
12
CUT RED WIRE #12
CRIMP ON 2 FEMALE TERMINALS
CONNECT TO &
ON PORTION CONTROL BOARD
L2 VALVE COMM
CUT BLUE WIRE #13
CONNECT ENDS AND CRIMP ON
FEMALE TERMINAL
CONNECT TO ON
PORTION CONTROL BOARD
L1
NEW WIRING HARNESS
EXISTING WIRES
BLUE
RED
RED
WHITE
13
13
REMOVE TAPE FROM 2 TERMINALS
ON BLUE WIRE #14
CONNECT TO CONNECTOR
OF LEFT AND CENTER SWITCHES
FRONT