  • Hello! I am an AI chatbot trained to assist you with the Heartland 1902000WHT Site Preparation. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation Requirements
Due to continuing product improvements, AGA Marvel reserves the right to amend specifica-
tions without notice. Please contact AGA Marvel for the most up to date information, as it applies to product
being purchased, or download latest Site Preparation Specifications from www.heartlandapp.com.
Help Desk
800-223-3900
1
© 2010 AGA MARVEL
Models 1902/1903 (page 1 of 2)
STOVE PIPE & CHIMNEY
REQUIREMENTS
Note: Information herein is for recommendation pur-
poses only. All clearances are subject to local, Provin-
cial or State building and fire codes. Clearances may
change without notice. Always consult with local build-
ing inspector. Improperly installed and/or maintained
stoves may result is a house fire.
Chimney Stove Pipe Approvals:
Chimney used to connect smokepipe at the top of
the cabinet to maintain the 4” clearance to
combustibles must be approved to the following
standards:
Canada: ULC Standard S629.
US: UL 193HT Standard.
Approved chimney must extend 1below the
heatshield.
Note: Information herein is for recommendation purposes only.
All clearances are subject to local, Provincial or State build-
ing and fire codes. Clearances may change without notice.
Always consult with local building inspector. Improperly
installed and/or maintained stoves may result is a house fire.
OVAL WOOD STOVE
REQUIREMENTS
How-to Steps
How-to Steps
Heat Shield Installation - Optional Kit # -
reduces clearances required to combusti-
ble walls (see page 2 of 2 for details)
Rear clearance to combustible wall: 14-
3/4” (37.5 cm).
Rear clearance to back of stove top: 12-
3/4” (32 cm)
Note: stove top overhangs back of stove
by 2” (5 cm).
Centerline of 6” exhaust pipe to com-
bustible back wall: 8-3/4” (22 cm). Note:
clearance may be affected by stove pipe
manufacturer’s recommendations.
Combustible Walls:
Please contact your local building inspector for
confirmation of what construction materials are
considered “combustible” or “non-combustible” in
your particular application. Combustible materials
include, but not limited to, doors, trim, furniture, drapes,
newspapers, wood piles and clothes.
For methods to reduce clerances to combustibles refer
to: CAN: CAN3-B365-M84; US: NFPA Standard 211
Hearth or pad extension from front of stove: 18” (45 cm)
Hearth/pad extension from sides & back of stove: 8” (20
cm).
Hearth extension may be fabricated from non-combustible
materials: 1/2” (13 mm) thick minimum with thermal conduc-
tivity factor “K” of 0.43 or lower (units of K = btu/ft/h/F/in).
To determine thickness of equivalent material required use
formula: (“K” x 0.5) / 0.43 = thickness required (“K” value can
be obtained from manufacturer of floor material).
Safety
Clearance Guidelines:
Part of planning a safe installation is to
be sure that combustible materials
located near your stove do not
overheat.
Floor Protection - combustible floor:
Continuous noncombustible floor protector pad
or Hearth is required under the stove (i.e. floor
tiles with grouting between them or metal pads
are acceptable).
Safety
Clearances specified herein must be adhered to
as a minimum. Local building codes may
require additional spacing. Please confirm with
your local regulations prior to commencing any
work.
Floor or ceiling supports must not be cut due to
chimney installation (adjust stove location
accordingly to avoid chimney interference with
these critical areas).
Certain States require fresh air supply kits to be
installed, contact state or local authorities for
specific details prior to installing unit.
Clearance reductions may be possible using
Heartland’s Heat Shield Kit. To ensure the
appropriate
standards are being met, in Canada
refer to the Installation Code for Solid Fuel
Appliances and Equipment. CAN3-B365-M84;
in the U.S. refer to the National Fire Protection
Association Standard 211.
Do not pass stovepipe chimney connector
through combustible wall.
Always use an approved insulated wall/ceiling
pass-through (refer to CSA B365 in Canada
and NFPA 211 in US).
Do not use single wall smokepipe as an outside
chimney
Chimney connector should be exposed and
accessible for inspection and cleaning (never
pass through combustible ceiling)
Connector must be securely attached to the
pipe
and chimney. Individual sections must be
attached together (in case of chimney fire,
chimney connector may vibrate violently)
Stove not be connected to an air distribution
duct.
Appliance Clearances (see Page 2 for additional details):
Left side of stove and/or nickel trim to adjacent combusti-
ble surfaces: 24” (61 cm)
Right side of stove and/or nickel trim to adjacent combus-
tible surfaces: 10” (25 cm). Distance measured to outer
edge of either towel rack (model 1902) or water reservoir
(model 1903) accordingly.
Rear clearance to combustible wall: 27” (68 cm).
Rear clearance to back of stove top: 25” (64 cm)
Note: stove top overhangs back of stove by 2” (5 cm).
Minimum clearance to combustible ceiling: 52” (132 cm)
Corner clearance to combustible wall: 26” (66 cm).
Centerline of 6” exhaust pipe to combustible back wall: 24”
(61 cm). Note: clearance may be affected by stove pipe
manufacturer’s recommendations.
Warning
oval.110811
Installation Requirements
Due to continuing product improvements, AGA Marvel
reserves the right to amend specifications
without notice. Please contact AGA Marvel
for the most up to date information, as it applies to product
being purchased, or download latest Site Preparation Specifications from www.heartlandapp.com.
Help Desk
800-223-3900
1
© 2010 AGA MARVEL
Models 1902/1903 (page 2 of 2)
Rough In
Measurements
Dimensions
All drawings are for reference
only, showing approximate
dimensions for rough-in
purposes. Do not cut floor or
ceiling supports due to chimney
installation.
Installation without Heat Shield
Installation with Heat Shield
Corner installation with or
without Heat Shield
In some installations, due to room orientation etc.,
two or more clearances to combustible walls may
contradict each other, the clearance with the greater
numerical value must be maintained.
Hearth
24”
(61 cm)
20-1/4”
(52 cm)
3-3/4”
(10 cm)
26-1/4”
(67 cm)
8”
(20.3 cm)
14-1/2”
(37 cm)
13-1/4”
(34 cm)
Combustible
Wall
18-7/8”
(48 cm)
32”
(81.3 cm)
12”
(31 cm)
62”
(158 cm)
47-1/8”
(120 cm)
8”
(20.3 cm)
35-1/2”
(92 cm)
3-7/8
(10 cm)
Combustible
Ceiling
6”
(15.3 cm)
11-13/16”
(30 cm)
8”
(20.3 cm)
18”
(46 cm)
27-1/8”
(69 cm)
22-1/2”
(57.2 cm)
35
(89 cm)
Hearth
20”
(51 cm)
Combustible
Wall
52”
(132.1 cm)
2” (5.1 cm)
overhang
7-1/8
(18.1cm)
Combustible
wall
26” (66 cm)
26” (66 cm)
Flue
pipe
Heat Shield
34” (86.4 cm)
no heat shield
17-1/2” (44.5 cm)
to heat shield
20-1/4”
(51.4 cm)
20” (51 cm)
23” (61 cm)
36” (91 cm)
Flue
pipe
27-1/8”
(69 cm)
24”
(61 cm)
10” (25 cm)
to reservoir
or towel rack
Reservoir
option
25” (64 cm)
to stove top
Combustible Walls
27”(68 cm)
to back of
stove
Top
extends
2”(5cm)
10-3/4
(27 cm)
13”
(33 cm)
20-1/4
(51.4 cm)
2” (5.1 cm)
8-3/4”
(22 cm)
3” (8 cm)
Heat Shield
Flue
pipe
27-1/8”
(69 cm)
24”
(61 cm)
10” (25 cm)
to reservoir
or towel rack
Reservoir
option
12-3/4
(32cm) to
stove top
Combustible Walls
36” (91 cm)
/