OMS P Valve User manual

  • Hello! I've reviewed the instruction manual for the OMS Bayonet Mount P-Valve. This document covers the installation, operation, and maintenance of the device which has unique features like the bayonet mount and a fast lock cap. I'm ready to address your questions regarding its setup, usage, or any other details outlined in the manual.
  • How does the Fast Lock Cap work?
    What is the purpose of the semipermeable membrane?
    What are some maintenance tips?
    Can i replace check valve?
OceanManagementSystemsGmbH
Klosterhofweg96
41199Mönchengladbach
omspvalvemanual110216.docxomspvalvemanual110216.docx
OMSBayonetMountPValve
InstructionManual
OceanManagementSystemsGmbH
Klosterhofweg96
41199Mönchengladbach
omspvalvemanual110216.docxomspvalvemanual110216.docx
DearCustomer,
YourOMS®Teamappreciatesyourconfidenceinchoosingourproduct.
Ourproductsaredesignedtooffercomfort,reliabilityandsafetyandaremanufacturedwith
onlyhighqualitymaterialsandtheutmostcare.Inaddition,eachproductisthoroughlytested
beforedeliverytoensurereliability.
AtOMS®wearecontinuouslyworkingtoimproveourproducts.Forthisreason,wewould
appreciateitifyouwouldpassonanythoughtsorcommentsontheuseordesignofour
productsto[email protected].
TheOMS®BayonetMountPValveincorporatesthreeuniqueinnovativebenefits.
Thebayonetmountsystemallowsthevalvetobequicklyandeasilyremovedfromthe
suitforroutinemaintenance.Thebayonetmountallowsthevalvetoberemovedanda
blankingpluginstalledfordiveswhenaPValveisnotneeded.
Thevalve’sbalanceddesignusesatraditionalProtectiveVacuumBreakerValvebacked
withasemipermeablemembrane,anOMS®originalfeature.Themembraneprevents
debrisfromenteringthevalveandfluidfromenteringthesuitintheeventofavalve
failure.
TheFastLockCapopensandcloseswithasimplequick1/3turnwhenaquickresponse
isneeded,versusthecommontwoormorefullturns.
Beforeinstallationanduseofthisproduct,pleasetakethetimetoreadthismanualindetail.
Withthecontentsofthismanual,youareequippedforproperoperationandlongterm
performance.
Youcancontactuswithanyquestionsaboutourproductsatanytime
YourOMS®Team

OceanManagementSystemsGmbH
Klosterhofweg96
41199Mönchengladbach
omspvalvemanual110216.docxomspvalvemanual110216.docx
BayonetValveOverview(Whatisinthebox)

OceanManagementSystemsGmbH
Klosterhofweg96
41199Mönchengladbach
omspvalvemanual110216.docxomspvalvemanual110216.docx
Installation
MaterialsNeeded
TheinstallationofthePValvemustbecarriedoutonlyby
authorizedpersons.
Youwillneedthefollowing:
OMS®Pvalve
Aquaseal®(Aquaseal®Cotol240™Combopack
containsAquaseal®,Cotol240™andapplication
brush)(Aquasure®isareplacementinEurope)
OMS®PValvebodywrenches
Marker:Wax,Crayon,Chalk
Punch38mmor11/2inch
Punchblockorpieceofwood
Hammer
60to80gritsandpaper
InstallationProcess
DisassemblePValve(fromtheoutofboxassembly)
1. RotatetheFastLockCapfullyclockwisetothefully
closedpositionandyouwillfeelasolidstop,then
rotatecap1/3ofaturncounterclockwise,tillyou
feelastop.Thenpressdownandrotatethecapan
additional1/3counterclockwise.Thecapshould
becomeloose.Pullthecapupanditwillcomefree.
Onlyalittleforceisneededtodothis.
2. RemovePValvebodyfromthebayonetmountring
assembly.Whileholdingthebayonetmountingring
assemblypressthePValvebodydown,
compressingthespringmechanismandthenrotatethevalvebody90degreesclockwise
orcounterclockwiseandthevalvebodywillcomefree.
3. Unthreadthebayonetmountringassembly
DeterminePositionandConnectionHoseAngleforPValveInstallation
Thisisthemostimportantstepintheprocess;apoorlyplacedPValvewillleadtokinked
connectionhosesandpoorperformance.Aproveninstallationpositionisonthefrontofthe
thigh,slightlyoffsetinwards3045degrees.Theinwardrotationisneededbecausethevalve
protrudesandoffsettingitreducessnaggingproblems,howevertoofarinwardsandthevalve
caninterferewithkickingand/orlegmovement.Inaddition,accessibilitytotheFastLockCapis
criticalforthevalve’sproperoperation.
Ideally,thedivershoulddonboththeirdrysuitanddiveweartomakethiscriticalpositioning
decision.First,donthedivewear,allthelayerstheyplantowear.Thefirstdecisioniswhich
OceanManagementSystemsGmbH
Klosterhofweg96
41199Mönchengladbach
omspvalvemanual110216.docxomspvalvemanual110216.docx
thightomountthevalveon,eithertheleftorright.Formenitissimplyhowdoyouwearyour
pants“dressedleft”or“dressedright”?Forwomenitismoreaquestionofpersonalpreference
anddivewearfeatures.Thispreferencedictatesthepreferredthighforvalveplacementand
oncethisdecisionhasbeenmadetherearetwoadditionalfactorstoconsider.Thefirstisthe
positionofthevalveonthethighandthesecondistheplannedroutingoftheconnectiontube
betweenthevalveandtheexternalcatheter.Istheroutingstraightup,sothattheconnection
hosepassesthoughthebaseoftheundergarment’szipperorifroutedatananglesothatitcan
passthoughthePValveconnectiontubeportsbuiltintotheundergarments.Sometimesthese
portsareupbythebaseand/orthesideofthezipperandothertimestheyarelocatedonthe
thighoftheundergarment.
Tooptimizethesedecisions,itisbesttostartbydressingoutinyourundergarmentandany
otheritemstobewornundertheundergarmentsothattheroutingoftheconnectiontubecan
beestablished.Itiscriticalthattheconnectingtubedoesnotmakeanysharpturnswhichcould
kink,whichcouldrestrictorblockflow.
Aftertheroutingplacementandconnectinghoseanglehasbeendetermined,donthedrysuit
andmarkthePValvepositionwithchalkorawaxmarkingpen.Anadditionalfactortoconsider
isthata“good"positionisalwaysawayfromandnotonaseam.
Cuttheholeinthedrysuit
Themarkedholecanbecutwithscissorsorpunchedwithapunchandhammer.Asharppunch
producesthebestresults.Theidealholediametershouldbe11/2inches(38mm).When
punchingthehole,itisveryimportanttohaveastablepunchingblockontheundersideofthe
layerbeingpunchedthroughtoensurethattheunderlyingsuitmaterialisnotpunchedthrough
ordamagedintheprocess.
Somesuitmaterialsarequiteresilient,thereforeitisrecommendedtohitthepunchwith
severalblows,withoutliftingthepunchbetweenstrikes.Liftingthepunchcanleadtomore
thanoneholeandpartiallypunchedholesdeveloping.
InstallationofBayonetBase
Itemsneeded:BayonetBase,RetainingRingandTools
Turnthedrysuitinsideoutbeforeproceedingwiththeinstallationofthevalvebase.Youwant
thesuitlayingoutinsuchamannerthatyouhaveaccesstobothsidesofthepunchedhole.
Thisneedstobedonesothataproperconnectionhoseanglecanbecontrolled.
Beforefinallymountingthebayonetsystem,thedrysuitandthepartstobeassembledshould
becleanedandfreeofgreaseforbetterapplyingAquaseal®.Cotol240™isidealforcleaning
thesesurfaces.Thesealingsurfacesofthebayonetbasecanbelightlysandedtoimprovethe
bond.Remembertocleanaftersanding.
OceanManagementSystemsGmbH
Klosterhofweg96
41199Mönchengladbach
omspvalvemanual110216.docxomspvalvemanual110216.docx
g
that
p
AfilmofAquaseal®shouldbeappliedtothesealingsurfaceofthebayonetbase.Donotapply
theAquaseal®allthewaytotheouteredgeofthebayonetbase.Applyitabout¼”(6mm)out
fromthethreads.
Placethebayonetbaseinthepunched
holeontheinsideofthesuittakingcareto
adjustthetwoparallellinesonthe
bayonetbasetothedesireddirectionyou
wishtheconnectionhosetoberouted.
Threadthelockingringinplaceonthe
outsideofthesuitandthreadontillhand
tight,allthewhiletakingcarethatthetwo
parallelsurfacesonthebayonetlockin
ringstayaligned.Oncefingertight,usethesuppliedwrenchestosnugtheringsinplace,always
payingattentiontothealignmentofthebayonetlockingring.Wipeupanyexcessadhesive
extrudesfromunderthebayonetlockingring.Itisagoodideatowaitafewhoursbefore
proceedingtothenextstep.Iftheadhesiveshavenotbeenallowedtocurethealignmentof
thebayonetlockingringcouldshift.
InstallingthePValveBodyandFastLockCap
TheFastLockCapshouldberemovedifyouhavereplacedit.Fromthe
insideofthesuit,alignthetwostraightparallelsideswithvalvebody
withtheparallelstraightsidesofthebayonetmount.Pressinplace
thenrotateclockwiseto90degrees.Onceyoustartrotating,release
thedownwardtensionandvalvebodywilllockinplaceonceitreaches
90degrees.Oncelockedinplacethevalvebodywillnotrotateunless
youapplydownwardpressure.
TurnthesuitrightsideouttoinstalltheFastLockCap.Beforeinstalling
thecapmakesurethespringisstillinplace.Alignthethreeguidepins
withthethreeguidechannelsinthevalvebody.Whilemaintaining
downwardpressure,rotatethecap1/6ofaturnclockwise.Onceastop
hasbeenreached,stoppressingdown.Thecapspringwillpushtheca
upwhichisthenormalopenposition.Tomovetotheclosedposition
continuetorotatethevalve1/3clockwise.
ValveOperation
WhentheFastLockCapisturnedfullyclockwiseandsnugagainststop,
thevalveiscompletelyclosedandinoperable.Nofluidscanbe
dischargedorenterthesuit.Whenthecapisturnedcounterclockwise
approximately1/3ofaturn,thevalveisoperationalandinfully
automaticdivemode.Indivemode,fluidscanbedischargedatwill,but
watercannotreenterthevalveduetotheonewaycheckvalve.The
OceanManagementSystemsGmbH
Klosterhofweg96
41199Mönchengladbach
omspvalvemanual110216.docxomspvalvemanual110216.docx
FastLockCapisonlyclosedintheeventofonewaycheckvalvefailure.Itisbesttocheckthe
functionofthePValvesystembeforefullygearingupandenteringthewaterbysimply
urinating.
FailureModes
Inabilitytopassfluidsthroughvalve
Capisclosed
ConnectionHoseKinked:Theuseofthenorprenetubinghasdrasticallyreducedthe
likelihoodofakinkedhose.Thevalveisbestpositionedtoavoidsharpbendsinthehose
routingtofurtherreducetheriskofkinking.UseonlyOMS®PValvehoseforany
replacements.
KinkortwistinCondomCatheter:Thismayoccurintheeventthatthecatheterwasnot
properly/completelyinstalled.Blockagesinflowmaybeduetoasharpbendattheend
ofthecatheter,orarestrictioncreatedbytheadhesivewithinthecatheter.Besureto
followthecatheterinstructionscarefully.
CheckValveFailure:Debrisordepositscanbuilduponthecheckvalveovertimeand
interferewiththeirfunction.Followingaperiodicmaintenanceandcleaningscheduleis
recommended.
SeaWaterEnteringtheSystem
CloseFastLockCap
CatheterSqueeze
FailureofVacuumBreakerCheckvalve,abortdiveand/orserviceorreplaceVacuum
BreakerCheckValve
MaintenanceandCleaning
TheOMS®PValve,likeallvalvesusedinscubadiving,musthaveabasicmaintenancecheckon
regularintervals.Ifnotcleanedproperly,organicandinorganicdepositswill,overtime,reduce
thevalve’sabilitytofunctionproperly.Additionally,regularcleaningoftheStreamlinePValve
isessentialinpreventingbacterialgrowththatcouldcontributetoaurinarytractinfection.
SeveralcarefulrinsesofthePValvewithamildvinegar/watersolutionarerecommendedafter
eachdive.Manyusershavefoundthatalargesqueezebottleorlargeboremedicalsyringe
workswelltointroducethesolutionthroughthecatheterinterface,andflushthevalve
thoroughly.
CheckValveReplacement
OceanManagementSystemsGmbH
Klosterhofweg96
41199Mönchengladbach
omspvalvemanual110216.docxomspvalvemanual110216.docx
Toinspectorreplacethemainumbrellavalve,removethecap.Lifttheedgesoftheumbrella
valvetoexposethecenterstem.Graspthestemfirmly,andgentlyworkitfreewithasideto
siderockingmotion.Toinstallanewumbrellavalve,slipthecenterstemintotheretaininghole
inthemiddleofthevalveface.Applygentlepressuretothecenteroftheumbrellavalve,until
itbecomesfullyseated.Toinspectorreplacethebalancedcheckvalvewithintheinternalvalve
body,useacointounscrewtheretainer.Theduckbillvalvecanthenberemovedfor
inspection/replacement.Whenreinstallingtheretainer,besurenottoovertightenthefitting.
WarrantyInformation
AllwarrantyrequestsmustbeaccompaniedbyproofoforiginalpurchasefromanAuthorized
OMS®Dealer.Besuretosaveyoursalesreceipt,andpresentitwheneverreturningyourOMS®
gearforwarrantyservice.
OMS®warrants,totheoriginalpurchaseronly,thattheOMS®PValvewillbefreeofdefectsin
materialsand/orcraftsmanshipundernormaldivingusefortwoyearsfromthedateof
purchase,providedpropercareisperformedonallmaterialsasdescribedwithinthismanual.
ShouldyourPValveprovetobedefectiveforanyreasonitwillberepairedorreplaced(at
OMS®discretion)freeofchargeexcludingshippingandhandlingcharges.
OMS®PValvesparesparts
120918002Valve body
220918003Duckbill check valve
320918004Washer (duckbill check valve) Nylon FG black
420918005Protection valve
520918006Male thread pipe fitting barb hose tail connector with O-ring
620918007Neoprene Tube A-60-G
720918008Coupling insert - inHose/hose barb
820918009Coupling body - inHose/hose barb
920918010O-ring (Basic body/Blind plug)
1020918011Umbrella check valve
1120918012Valve holder (umbrella check valve)
1220918013O-Ring (Valve holder)
1320918014Conical spring
1420918015Cap W/O Logo
1520918016Stainless steel dowel pin
1620918017O-Ring (Cap)
1720918018Lockring
1820918019Bayonet base
1920918020Wave spring washer
2020918021Blind Plug w/o Logo
OceanManagementSystemsGmbH
Klosterhofweg96
41199Mönchengladbach
omspvalvemanual110216.docxomspvalvemanual110216.docx
AccessoryKit
OMS®Catheters20916902OMS®CathetersMed29mmSilicon
/