Generac 30kW 0066781 User manual

Type
User manual
4 3 2 1
4 3 1
A
B
A
B
2424 [95.4] OVERALL LENGTH
1625 [64.0]182 [7.2]
581
[22.9]
1686 [66.4]
OVERALL
HEIGHT
888 [35.0]
OVERALL WIDTH
173
[6.8]
618 [24.3]
1021 [40.2]
CENTER OF GRAVITY
SEE NOTE 5
SERVICE ITEM 2.4L
OIL FILL CAP LEFT SIDE
OIL DIP STICK RIGHT SIDE
OIL FILTER RIGHT SIDE
OIL DRAIN HOSE RIGHT SIDE
RADIATOR DRAIN HOSE LEFT SIDE
AIR CLEANER ELEMENT LEFT SIDE
MUFFLER FRONT
FAN BELT EITHER SIDE
BATTERY LEFT SIDE
WEIGHT DATA WITH EMPTY BASETANK
(SEE NOTE 5)
GENERATOR AS SHOWN (STEEL ENCL) 992 [2187]
WITH WOODEN SHIPPING SKID 1037 [2287]
TITLE
INSTALL SPRINT D2.4L 30KW
ISSUE DATE:
SIZE CAGE NO DWG NO
0K7117
REV
B
A
SCALE
0.050
WT-KG SEE ABOVESHEET
1 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
SH
1/2
REV
A
WINDCHILL VERSION
A.1
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2718 (107") LONG.
REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT
FOR CONCRETE PAD GUIDELINES
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF
GENERATOR
4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 35 INCHES H2O.
8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
9. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
REFERENCE OWNERS MANUAL FOR PERIODIC
REPLACEMENT PART LISTINGS.
LEFT SIDE VIEW
REAR VIEW
RIGHT SIDE VIEW
TOP VIEW
RADIATOR/EXHAUST
DISCHARGE AIR
VICE ACTION LATCH, ONE PER DOOR,
LIFT-OFF DOORS ON FRONT,
RIGHT, AND LEFT SIDES
LIFT OFF DOOR PROVIDES
ACCESS TO: FUEL FILL, FUEL
LEVEL GAUGE, NORMAL VENT,
INNER TANK EMERGENCY
VENT, OUTER TANK
EMERGENCY VENT, OPTIONAL
90% ALARM ASSEMBLY,
OPTIONAL 5 GALLON SPILL
BOX
FUEL TANK
VENTILATION DUCT
OPEN PUNCHED LOUVERS TYPICAL
ON BOTH SIDES OF
FUEL TANK VENTILATION
DUCT TO PROVIDE ADEQUATE
CROSS-FLOW OF AIR VENTILATION
EXHAUST MUFFLER ENCLOSED WITHIN
GENERATOR ENCLOSURE
REAR TANK COVER
SEE NOTE 4
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
CIRCUIT BREAKER
SEE NOTE 3
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
LIFTING PROVISIONS (4 PLACES)
SEE NOTES 5, 8, AND CENTER OF GRAVITY DIMENSIONS
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
AIR INTAKE
(BOTH SIDES)
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
BATTERY 12 VOLT
NEGATIVE GROUND
INTERNAL DIVIDER PANEL
SEPARATES FUEL TANK VENTILATION
DUCT FROM THE ENGINE,
ALTERNATOR AND EXHAUST SYSTEM
REMOVE PANEL
TO ALLOW
TANK VENTS TO
TERMINATE
OUTSIDE
OF THE
GENERATOR
ENCLOSURE
(CHECK LOCAL
AND
STATE CODE FOR
APPLICABILITY)
4 3 2 1
4 3 1
A
B
A
B
247
[9.7]
280
[11.0]
485
[19.1]
314
[12.4]
658
[25.9]
117
[4.6]
247
[9.7]
377
[14.9]
2089 [82.2]
1308 [51.5]
1418 [55.8]
264
[10.4]
618
[24.3]
121
[4.8]
196 [7.7]
STUB-UP
AREA
2226
[87.6]
38
[1.5]
125
[4.9]
715
[28.1]
51
[2.0]
786 [30.9]
STUB-UP
AREA
2424 [95.4]
110 [4.3]
690 [27.2]
1216 [47.9]
1769 [69.6]
2322 [91.4]
632
[24.9]
888 [35.0]
851 [33.5]19 [.7]
850 [33.5]
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
TITLE
INSTALL SPRINT D2.4L 30KW
ISSUE DATE:
SIZE CAGE NO DWG NO
0K7117
REV
B
A
SCALE
0.075
WT-KG SEE ABOVESHEET
2 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
SH
2/2
REV
A
WINDCHILL VERSION
A.1
FUEL TANK
TOTAL CAPACITY 524 [138.5]
USABLE CAPACITY 500 [132]
CAPACITY: LITER [GALLON]
DIMENSIONS: MM [INCH]
TANK IS LISTED TO UL142 AND
ULC/ORD C142.18
CUSTOMER OPTION
(2" NPT FEMALE)
OUTER TANK LEAK DETECTOR
FUEL SUPPLY
FUEL RETURN
INNER TANK EMERGENCY VENT
(3" NPT FEMALE)
INNER TANK NORMAL VENT
(2" NPT FEMALE)
OUTER TANK
EMERGENCY VENT
(3" NPT FEMALE)
FUEL FILL
FUEL LEVEL
GAUGE/SENDER
HIGH AND LOW VOLTAGE
STUB-UP AREA
CIRCUIT BREAKER,
NEUTRAL AND CUSTOMER
CONNECTION OPENING
16.66 [.656] MOUNTING HOLES
(10 PLACES) SEE NOTE 10
  • Page 1 1
  • Page 2 2

Generac 30kW 0066781 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI