Quadrafire 3100 Millennium ACC Install Manual

Type
Install Manual

Quadrafire 3100 Millennium ACC is a high-efficiency wood-burning appliance that provides warmth and ambiance to your home. With its advanced design and construction, the appliance is easy to install and operate, and it meets the latest environmental standards.

The 3100 Millennium ACC features a large viewing area, providing a captivating view of the flames. The appliance is also equipped with a variable-speed blower, which allows you to adjust the heat output to your desired comfort level.

The appliance is constructed of heavy-duty materials, including a cast iron firebox and a welded steel body. This ensures durability and long-lasting performance. The appliance is also dilengkapi with a durable ceramic glass door, which provides a clear view of the fire and helps to keep heat in.

Quadrafire 3100 Millennium ACC is a high-efficiency wood-burning appliance that provides warmth and ambiance to your home. With its advanced design and construction, the appliance is easy to install and operate, and it meets the latest environmental standards.

The 3100 Millennium ACC features a large viewing area, providing a captivating view of the flames. The appliance is also equipped with a variable-speed blower, which allows you to adjust the heat output to your desired comfort level.

The appliance is constructed of heavy-duty materials, including a cast iron firebox and a welded steel body. This ensures durability and long-lasting performance. The appliance is also dilengkapi with a durable ceramic glass door, which provides a clear view of the fire and helps to keep heat in.

1 7033-328C May 09, 2017
3100 Millennium Wood Appliance
Model(s):
31M-ACC-MBK
WARNING
If the information in these instruc-
tions is not followed exactly, a
re could result causing property
damage, personal injury, or death.
• Donotstoreorusegasolineorotheram-
mablevaporsandliquidsinthevicinityof
thisoranyotherappliance.
• Donotoverre-Ifapplianceorchimney
connectorglows,youareoverring.Over
ringwillvoidyourwarranty.
• Complywithallminimumclearancesto
combustiblesasspecied.Failureto
complymaycausehousere.
HOT SURFACES!
Glassandothersurfacesarehot
duringoperationANDcooldown.
Hot glass will cause burns.
Donottouchglassuntilitiscooled
NEVERallowchildrentotouchglass
Keepchildrenaway
CAREFULLY SUPERVISE children insame room as
replace.
Alertchildrenandadultstohazardsofhightemperatures
High temperatures may ignite clothing or other
ammable materials.
Keepclothing,furniture,draperiesandotherammable
materialsaway.
WARNING
WARNING
Fire Risk.
Forusewithsolidwoodfuelonly.
Otherfuelsmayoverreandgeneratepoisonous
gases(i.e.carbonmonoxide).
Installation Manual
Installation & Appliance Set-Up
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT DISCARD THIS MANUAL
NOTE
ToobtainaFrenchtranslationofthismanual,pleasecontact
yourdealerorvisitwww.quadrare.com
Pourobtenirunetraductionfrançaisedecemanuel,s’ilvous
plaîtcontactervotrerevendeurouvisitezwww.quadrare.com
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
2 7033-328C May 09, 2017
3100 Millennium Wood Appliance
1 Important Safety Information ...........3
A.ApplianceCertication.............................................3
B.BTU&EfciencySpecications..............................3
C.MobileHomeApproved........................................... 3
D.GlassSpecications................................................3
E.Non-CombustibleMaterials......................................3
F.CombustibleMaterials..............................................3
2 Getting Started ..................................4
A
.DesignandInstallationConsiderations....................... 4
B.FireSafety................................................................4
C.NegativePressure.................................................4
D.ToolsAndSuppliesNeeded....................................5
E.InspectApplianceandComponents........................5
F.RemovalofAppliancefromShippingMaterials.......5
G.InstallChecklist........................................................6
3 Dimensions and Clearances ............7
A.ApplianceDimensions.............................................7
B.HearthProtectionRequirements.............................8
C.ClearancestoCombustibles...................................9
4 Chimney Systems ...........................10
A.LocatingYourAppliance&Chimney.......................10
B.ChimneyTerminationRequirements.......................11
C.2-10-3Rule..............................................................11
D.ChimneyHeight/RiseandRun.................................12
E.VentingComponents................................................12
F.ChimneySystems.....................................................12
G.InstallingChimneyComponents..............................14
H.ProperDraft............................................................14
5 Appliance Set-Up ............................15
A.OutsideAirKitInstallation.......................................15
B.DoorHandleAssembly............................................16
C.Blower(Optional)....................................................16
6 Mobile Home Installation ................17
7 Reference Materials ........................18
8 Accessory List ................................19
TABLE OF CONTENTS
Safety Alert Key:
DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.
WARNING!Indicatesahazardoussituationwhich,ifnotavoidedmayresultindeathorseriousinjury.
CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,mayresultinminorormoderateinjury.
NOTICE:Indicatespracticeswhichmaycausedamagetotheapplianceortoproperty.
Quadra-FireisaregisteredtrademarkofHearth&HomeTechnologies.
May 09, 2017 7033-328C 3
3100 Millennium Wood Appliance
Model:
3100MillenniumWoodAppliance
Laboratory: OMNITestLaboratories,Inc.
Report No:
0061WS066S
Type:
ListedRoomAppliance,SolidFuel
Type
Standard: UL1482-11(R2015)andULCS627-
00and(UM)84-HUD,MobileHome
Approved.
TheQuadra-Fire3100SeriesWoodAppliance(ACC)meets
theU.S.EnvironmentalProtectionAgency’scribwoodemis-
sionlimitsforwoodappliancessoldafterMay15,2015.
EPACertication#: 649
EPACertiedEmissions: 1.1gramsperhour
*LHVTestedEfciency: 79.9%
**HHVTestedEfciency: 74%
***EPABTUOutput: 11,700to32,000/hr.
****PeakBTU/HourOutput: 57,200
VentSize: 6inches
FireboxSize: 2cubicfeet
RecommendedWoodLength: 16inches
FuelOrientation: Front-to-Back
Fuel SeasonedCordWood
*Weighted average LHV (Low Heating Value) efciency using
DouglasFirdimensionallumberanddatacollectedduringEPA
emissiontest.LHVassumesthemoistureisalreadyinavapor
statesothereisnolossinenergytovaporize.
**WeightedaverageHHV(HighHeatingValue)efciencyusing
DouglasFirdimensionallumberanddatacollectedduringEPA
emissiontest.HHVincludestheenergyrequiredtovaporizethe
waterinthefuel.
***ArangeofBTUoutputsbasedonEPADefaultEfciencyand
theburnratesfromthelowandhighEPAtests,usingDouglas
Firdimensionallumber.
****ApeakBTUoutoftheappliancecalculatedusingthemax-
imumrsthourburnratefromtheHighEPATestandtheBTU
contentofcordwood(8600)timestheefciency.
Improper installation, adjustment, alteration, service or
maintenancecancauseinjuryorpropertydamage.
Forassistanceoradditionalinformation,consultaqualied
installer,serviceagencyoryourdealer.
Hearth&HomeTechnologiesWILLNOTwarrantyappli-
ancesthatexhibitevidenceofover-ring.Evidenceof
over-ringincludes,butisnotlimitedto:
• Warpedairtube
• Deterioratedrefractorybrickretainers
• Deterioratedbafeandotherinteriorcomponents
D. Glass Specications
Thisapplianceisequippedwith5mmceramicglass.
Replaceglassonlywith5mmceramicglass.Pleasecon-
tactyourdealerforreplacementglass.
NOTE:Hearth&HomeTechnologies,manufacturerof
thisappliance,reservestherighttoalteritsproducts,their
specicationsand/orpricewithoutnotice.
C. Mobile Home Approved
Thisapplianceisapprovedformobilehomeinstalla-
tions;whennotinstalledinasleepingroomandwhen
anoutsidecombustionairinletisprovided.
Thestructuralintegrityofthemobilehomeoor,ceil-
ing,andwallsmustbemaintained.
Theappliancemustbeproperlygroundedtotheframe
ofthemobilehomewith#8coppergroundwire.
OutsideAirKit,partOAK-ACCmustbeinstalledina
mobilehomeinstallation.
F. Combustible Materials
Materialmadeof/orsurfacedwithanyofthefollowingma-
terials:
-Wood -CompressedPaper
-PlantFibers  -Plastic
-Plywood/OSB -SheetRock(drywall)
Anymaterialthatcanigniteandburn:ameproofedornot,
plasteredornon-plastered.
E. Non-Combustible Materials
Materialwhichwillnotigniteandburn,composedofany
combinationofthefollowing:
-Steel -Plaster
-Brick -Iron
-Concrete -Tile
-Glass -Slate
MaterialsreportedaspassingASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace of 750° C.
1 Important Safety Information
A. Appliance Certication
B. BTU & Efciency Specications
NOTE: Thisinstallationmustconformwithlocalcodes.Inthe
absenceoflocalcodesyoumustcomplywith (UM) 84-HUD and
NFPA211 intheU.S.A.andCAN/CSA-B365 Installation Codes in
Canada.
4 7033-328C May 09, 2017
3100 Millennium Wood Appliance
Install Guide
2 Getting Started
A. Design and Installation Considerations
Considerationmustbegivento:
• Safety
• Convenience
• Trafcow
• Chimneyandchimneyconnectorrequired
Itisagoodideatoplanyourinstallationonpaper,usingexact
measurements for clearances and oor protection, before
actuallybeginningtheinstallation.Ifyouarenotusingan
existingchimney,placetheappliancewheretherewillbea
clearpassageforafactory-builtlistedchimneythroughthe
ceilingandroof.
Werecommendthataqualiedbuildinginspectorandyour
insurancecompanyrepresentativereviewyourplansbefore
andafterinstallation.
Ifthisapplianceisinanareawherechildrenmaybenearitis
recommendedthatyoupurchaseadecorativebarriertogo
infrontoftheappliance.
Remembertoalwayskeepchildren
away while it is operating and do not let anyone operate
thisapplianceunlesstheyarefamiliarwiththeseoperating
instructions.
WARNING
• DONOTCONNECTTHISAPPLIANCETOACHIM-
NEYFLUESERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTION
DUCTORSYSTEM.
Mayallowuegasestoenterthehouse.
Asphyxiation Risk.
Checkbuildingcodespriortoinstallation.
• Installation MUST comply with local, regional, state and
nationalcodesandregulations.
Consult insurance carrier, local building, fire officials or
authorities having jurisdiction about restrictions, installation
inspection,andpermits.
CAUTION
NOTICE:HEARTH&HOMETECHNOLOGIESASSUMESNO
RESPONSIBILITY FOR THE IMPROPER PERFORMANCE
OFTHEAPPLIANCESYSTEMCAUSEDBY:
Inadequatedraftduetoenvironmentalconditions
• Downdrafts
• Tightsealingconstructionofthestructure
• Mechanicalexhaustingdevices
• Overdraftingcausedbyexcessivechimneyheights
• Ideal performanceiswith height ofchimneybetween 14-16
feet(4.26-4.88m)measuredfromthebaseoftheappliance.
To provide reasonable re safety, the following should be
givenseriousconsideration:
1. Install at least one smoke detector on each oor of
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer’splacementandinstallationinstructions,
andbesuretomaintainregularly.
C. Negative Pressure
Negative pressure results from the imbalance of air avail-
ablefor theappliancetooperateproperly.It canbestron-
gestinlowerlevelsofthehouse.
Causesinclude:
• Exhaustfans(kitchen,bath,etc.)
• Rangehoods
Combustion air requirements for furnaces, water
appliancesandothercombustionappliances
• Clothesdryers
• Locationofreturn-airventstofurnaceorairconditioning
• ImbalancesoftheHVACairhandlingsystem
• Upperlevelairleakssuchas:
- Recessedlighting
- Attichatch
- Ductleaks
WARNING
• Negativepressurecancausespillageofcom-
bustionfumes,sootandcarbonmonoxide.
• Applianceneedstodraftproperlyforsafety.
Asphyxiation Risk.
B. Fire Safety
2. A conveniently located ClassA fire extinguisher to
contendwithsmallresresultingfromburningembers.
3. ACOdetectorshouldbeinstalledintheroomwiththe
appliance.
4. Apracticedevacuationplan,consistingofatleasttwo
escaperoutes.
5. Aplantodealwithachimneyreasfollows:
Intheeventofachimneyre:
a Evacuatethehouseimmediately
b. Notifyredepartment.
May 09, 2017 7033-328C 5
3100 Millennium Wood Appliance
Figure 5.1
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installationand/oruseofanycomponentpartnotapproved
byHearth&HomeTechnologies.
• Operatingappliancewithoutfullyassemblingallcomponents.
• Operatingappliancewithoutlegsattached(ifsuppliedwith
appliance).
• DoNOTOverre-Ifapplianceorchimneyconnectorglows,
youareoverring.
Any such action that may cause a re hazard.
WARNING
Fire Risk.
Hearth&HomeTechnologiesdisclaimsany
responsibilityfor,andthewarrantywillbe
voidedby,thefollowingactions:
D. Tools And Supplies Needed
Beforebeginningtheinstallationbesurethefollowingtools
andbuildingsuppliesareavailable:
Reciprocatingsaw Framingmaterial
Pliers Hightempcaulkingmaterial
Hammer Gloves
Phillipsscrewdriver Framingsquare
Flatbladescrewdriver Electricdrillandbits
Plumbline Safetyglasses
Level Tapemeasure
Misc.screwsandnails 7/16socketorwrench
1/2-3/4in.length,#6or#8self-drillingscrews
• Removeapplianceandcomponentsfrompackagingand
inspectfordamage.
• Reporttoyourdealeranypartsdamagedinshipment.
Read all the instructions before starting the installation.
Follow these instructions carefully during the
installation to ensure maximum safety and benet.
E. Inspection of Appliance and Components
Inspectapplianceandcomponentsfordamage.
Damagedpartsmayimpairsafeoperation.
WARNING
• DoNOTinstalldamagedcomponents.
• DoNOTinstallincompletecomponents.
• DoNOTinstallsubstitutecomponents.
Reportdamagedpartstodealer.
Fire Risk.
Tominimizetheeffectsofnegativeairpressure:
Install optional outside air kit with the intake facing
prevailingwindsduringtheheatingseason
• Ensureadequateoutdoorairforallcombustionappliances
andexhaustequipment
• Ensurefurnaceandairconditioningreturnventsarenot
locatedintheimmediatevicinityoftheappliance
• Avoid installing the appliance near doors, walkways or
smallisolatedspaces
• Recessedlightingshouldbea“sealedcan”design
• Attichatchesweatherstrippedorsealed
• Atticmountedductworkandairhandlerjointsandseams
tapedorsealed
• Basementinstallationsshouldbeavoided
1.Removeboxand2x4structuralboardsbeingcareful
nottodamageproduct.
2.Using7/16socketorwrenchremoveoneboltlocated
insidefrontpartofappliance(Figure 5.1).
3.Movingtothebackoftheapplianceandusing7/16
socketorwrenchremovetwobolts(Figure 5.1).
4.Carefullypullapplianceoffofpalletandputindesired
location following Hearth Pad and Clearance to
Combustiblesonpages8and9.
F. Removal of Appliance from Shipping
Materials
2
3
6 7033-328C May 09, 2017
3100 Millennium Wood Appliance
G. Install Checklist
Appliance Install
Appliance is leveled and connector is secured to appliance.
Hearth extension size/height decided.
Outside air kit installed.
Floor protection requirements have been met.
If appliance is connected to a masonry chimney, it should be cleaned and
inspected by a professional. If installed to a factory built metal chimney, the
chimney must be installed according to the manufacturer’s instructions and
clearances.
Chimney
Chimney installed, locked and secured in place with proper clearance.
Chimney meets recommended height requirements (14-16 feet).
Terminations installed and sealed.
Clearances
Combustible materials not installed in non-combustible areas.
Mantels and wall projections comply with installation manual requirements.
Protective hearth strips and hearth extension installed per manual requirements.
Appliance Setup
All packaging and protective materials removed.
All labels have been removed from the door.
All packaging materials are removed from inside/under the appliance.
Manual bag and all of its contents are removed from inside/under the appliance
and given to the party responsible for use and operation.
ATTENTION INSTALLER:
Follow this Standard Work Checklist
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual.
Customer: __________________________________________________________________________
Date Installed: __________________________________________________________________________
Lot/Address: __________________________________________________________________________
Location of Appliance: ______________________________________________________________
Installer: __________________________________________________________________________
Dealer/ Distributor Phone #: ______________________________________________________________
Serial #: __________________________________________________________________________
Model : __________________________________________________________________________
WARNING! Risk of Fire or Explosion!
Hearth & Home Technologies recommends the following:
• That this checklist remain visible at all times on the appliance until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed:
Comments communicated to party responsible by on
(Builder/Gen. Contractor) (Installer) (Date)
YES IF NO, WHY?
May 09, 2017 7033-328C 7
3100 Millennium Wood Appliance
24-3/8 in [618mm]
26-5/8 in [677mm]
31-3/8 in
[796mm]
19-3/4 in [501mm]
Figure 7.1 Front View
Figure 7.3 Side View
25-1/4 in [641mm]
29-1/2 in
[749mm]
15-1/8 in
[383mm]
21 in [533mm]
11 in
[278mm]
Figure 7.2 Top View
3-1/2 in
[89mm]
6-11/16 in
[170mm]
12-3/4 in
[323mm]
3 Dimensions and Clearances
A. Appliance Dimensions
NOTE:FlueCollarsizeis6inch(152mm)diameter(ID)
8 7033-328C May 09, 2017
3100 Millennium Wood Appliance
B. Hearth Protection Requirements
EMBER PROTECTION: ItisnecessarytoinstallaTypeI
oorprotector.
Floorprotectormustbenon-combustiblematerial,extending
beneathappliance
withaminimumof16
inches(406mm)in
frontofglassand8inches(203mm)tobothsidesofthefuel
loadingdoor.Openthedoorandmeasure8inches(203mm)
fromthesideedgeoftheopeninginthefaceoftheappliance.
In Canada, It is required to install ember protection of 18
inches(457mm)infrontand8inches(203mm)fromthesides
andrearoftheappliance.Figure 8.2 *See exception.
*EXCEPTION: Non-combustible floor protections must
extendbeneaththeuepipewheninstalledwithhorizontal
ventingandextend2inches(51mm)beyondeachside.See
Figure 8.2
WARNING
Fire Risk.
Hearthpadsmustbeinstalledexactlyasspecied.
Hightemperaturesorhotembersmayigniteconcealed
combustibles.
16 in. from glass
8 in.
Fuel loading door
.
31-5/8 in.
minimum
39 in.
minimum
USA
Figure 8.2
Figure 8.1
Figure 8.3
203mm
203mm
203mm
457mm
1243mm
minimum
1041mm
minimum
Must extend 51mm
beyond each side
of pipe (shaded area)
CANADA
33-1
/4 in.
38-15/16 in.
3-1/16 in.
135°
optional
coverage
52-1/2 in.
31-5/8 in
60-5/8 in.
27-3/8 in.
USA
Corner hearth pad dimensions
withsinglewallpipe
Corner hearth pad dimensions
withdoublewallpipe
27-3/8 in.
31-3
/4 in.
38-15/16 in.
3-1/
16 in.
135°
optional
coverage
51 in.
31-5/8 in
58-1/2 in
.
USA
Figure 8.4
776mm
806mm
1243mm
135°
optional
coverage
1562mm
1041mm
1538mm
CANADA
1592mm
776mm
CANADA
Figure 8.5
Figure 8.6
May 09, 2017 7033-328C 9
3100 Millennium Wood Appliance
C. Clearances to Combustibles
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches (Millimeters)
Note: A, C, and F Dimensions are to the center of the flue collar
3100 Millennium
INSTALLATION: FULL VERTICAL
A B C D E F G H
SINGLE WALL PIPE
18-1/4 (464) 11-3/4 (298) 28-1/2 (724) 16 (406) 8 (203) 20 (508) 48 (1219) 12 (305)
DOUBLE WALL PIPE
13-1/2 (343) 6-1/2 (165) 25 (635) 13 (330) 6-1/2 (165) 18-1/2 (470) 48 (1219) 9 (229)
INSTALLATION: 90 DEGREE ELBOW OFF TOP OF APPLIANCE THROUGH BACKWALL
SINGLE WALL PIPE
15 (381) 8-1/2 (216) 25 (635) 13 (330) 8 (203) 20 (508) 48 (1219) 12 (305)
DOUBLE WALL PIPE
11 (279) 4-1/2 (114) 20-1/2 (521) 8-1/2 (216) 6-1/2 (165) 18-1/2 (470) 48 (1219) 9 (229)
INSTALLATION: ALCOVE
DOUBLE WALL PIPE
14-3/4 (375) 8-1/4 (210) 26-1/2 (673) 14-1/2 (368) N/A N/A 48 (1219) N/A
For alcove only: Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A
chimney or masonry chimney. Maximum depth of Alcove shall be no more than 48 inches (1219mm) and the referenced
alcove clearances. Canada must comply with CAN/ULC-S269 M87 for the 650° factory built chimney.
NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction
Fire Risk.
• Complywithallminimumclearancesto
combustiblesasspecied.
• Failuretocomplymaycausehousere.
WARNING
NOTE: Service Space
Inordertoreplacethetubechannelassemblyaclearanceof
19inches(483mm)isrequiredontherightsideofappliance
inordertoremovethetubeswiththeapplianceinplace.
Ifspaceisnotavailable,theappliancewillhavetobediscon-
nectedfromthechimneytoproceedwiththetubereplace-
ment.
BACKWALL / SIDEWALL
A B
C
D
E
F
F
E
CORNER INSTALLATION
C
ALCOVE TOP VIEW
G
A
ALCOVE SIDE VIEW
G
90° OFF TOP
UP & OUT CEILING
CLEARANCE
H
10 7033-328C May 09, 2017
3100 Millennium Wood Appliance
Recommended
Location
Marginal
Location
Location
Not
Recommended
Recommended
Location
Location NOT
Recommended
Multi-level Roofs
Windward
Leeward
Outside Air Kit Termination Cap
Figure 10.1
A. Locating Your Appliance & Chimney
Location of the appliance and chimney will affect perfor-
mance.AsshowninFigure 10.1thechimneyshould:
• Installthroughthewarmspaceenclosedbythebuild-
ingenvelope.Thishelpstoproducemoredraft,espe-
ciallyduringlightinganddiedownofthere.
• Penetratethehighestpartoftheroof.Thisminimizes
theaffectsofwindturbulenceanddowndrafts.
• Considertheappliancelocationinordertoavoidoor
andceilingatticjoistsandrafters.
Locate termination cap away from trees, adjacent
structures,unevenrooflinesandotherobstructions.
Yourlocaldealeristheexpertinyourgeographicareaand
canusuallymakesuggestionsordiscoversolutionsthatwill
easilycorrectyourueproblem.
4 Chimney Systems
May 09, 2017 7033-328C 11
3100 Millennium Wood Appliance
3ft.(91cm)
Minimum
Lessthan10ft.(305cm)
2ft.(61cm)
3ft.(91cm)
Minimum
10ft.(305cm) ToNearestRoofline
2ft.(61cm)
PitchedRoof
Figure 11.1
Figure 11.2
10 ft. (305cm) or more
3 ft. (91cm) Minimum
Less than 10 ft. (305cm)
2 ft. (61cm) Minimum
3 ft. (91cm) Minimum
Wall or Parapet
Flat Roof
C. 2-10-3 Rule
These are safety requirements and are not meant to
assure proper ue draft.
Thisapplianceismadewitha6inch(152mm)diameter
chimney connector as the ue collar on the appli-
ance.
• Changingthediameterofthechimneycanaffectdraft
andcausepoorperformance.
• Itis not recommended to use offsets and elbows at
altitudesabove4000feetabovesealevelandorwhen
thereareotherfactorsthataffectuedraft.
B. Chimney Termination Requirements
Followmanufacturer’sinstructionsforclearance,securing
ashingandterminatingthechimney.Fig. 11.1 & 11.2
MusthaveanapprovedandListedcap
Mustnotbelocatedwhereitwillbecomepluggedby
snoworothermaterial
• Mustterminateatleast3feet(91cm)abovetheroof
andatleast2feet(61cm)aboveanyportionofthe
roofwithin10feet(305cm).
• Mustbelocatedawayfromtreesorotherstructures
NOTICE:
• Chimneyperformancemayvary.
• Trees,buildings,rooflinesandwindconditionsaffect
performance.
• Chimneyheightmayneedadjustmentifsmokingor
overdraftoccurs.
NOTICE: Locating the appliance in a basement or in a
locationofconsiderableairmovementcancauseintermittent
smokespillagefromappliance.Donotlocateappliancenear
• Frequentlyopendoors
Central heat outlets or returns
12 7033-328C May 09, 2017
3100 Millennium Wood Appliance
NOTE: InCanadawhenusingafactory-builtchimneyitmust
besafetylisted, Type UL103 HT (2100
o
F) CLASS “A” or
conformingtoCAN/ULC-S629M, STANDARD FOR 650
o
C
FACTORY-BUILT CHIMNEYS.
F
loor
Pr
otector
Chimney
Connector
Insulated " T "
Flashing
Listed Termination Cap
Trim Collar on
Inside Wall
Listed Chimney
Storm Collar
Wall Support
Roof Brace (if required)
Thimble
Figure 12.1 Prefabricated Exterior Chimney
E. Venting Components
Chimney Connector:
Itisalsoknownasuepipeorappliancepipe.Thechimney
connectorjoinstheappliancetothechimney.Itmustbea6
inch(152mm)minimumdiameter24gaugemildsteelblack
or26gaugebluedsteel,oranapprovedair-insulateddouble
wallventingpipe.
Thimble:
A manufactured or site-constructed device installed in
combustible walls through which the chimney connector
passes to the chimney. It is intended to keep the walls
from igniting. Site constructed thimbles must meet NFPA
211Standards.Prefabricatedmustbesuitableforusewith
selectedchimneyandmeetUL103TypeHTStandards.Follow
instructionsprovidedbythemanufacturerformanufactured
thimblesformasonrychimneyandprefabricatedchimneys.
F. Chimney Systems
Prefabricated Metal Chimney
• Mustbeminimum6inch(152mm)diameter(ID)high
temperaturechimneylistedtoUL103HT(2100
o
F)or
ULCS629M.
• Mustusecomponentsrequiredbythemanufacturer
forinstallation.
• Mustmaintainclearancesrequiredbythemanufacturer
forinstallation.
• Refertomanufacturersinstructionsforinstallation.
D. Chimney Height / Rise and Run
Thisproductwasdesignedforandtestedona6inch(152mm)
chimney,14to16feet(420-480cm)high,(includesappliance
height)measuredfromthebaseoftheappliance.Thefurther
yourstackheightordiametervariesfromthisconguration,
thegreaterthelikelihooditmayaffectperformance.
Chimney height may need to be increased by 2
- 3% per
each1000feetabovesealevel.Itisnotrecommendedto
useoffsetsorelbowsataltitudesabove4000feetabovesea
levelorwhenthereareotherfactorsthataffectuedraft.
WARNING
Asphyxiation Risk.
• DONOTCONNECTTHISApplianceTOACHIM-
NEYFLUESERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTION
DUCTORSYSTEM.
Mayallowuegasestoenterthehouse.
Improperinstallation,adjustment,alteration,serviceormain-
tenancecancauseinjuryorpropertydamage.Refertothe
owner’sinformationmanualprovidedwiththisappliance.For
assistanceoradditionalinformationconsultaqualiedinstaller,
serviceagencyoryourdealer.
WARNING
Fire Risk.
InspectionofChimney:
•Chimneymustbeingoodcondition.
•MeetsminimumstandardofNFPA211
• Factory-builtchimneymustbe6inch(152mm)UL103HT.
WARNING
Chimney:
Thechimneycanbeneworexisting,masonryorprefabricated
andmustmeetthefollowingminimumrequirementsandas
speciedinSection4F.
May 09, 2017 7033-328C 13
3100 Millennium Wood Appliance
Floor
Protector
Chi
mney
Conne
ctor
Ceiling Support
Listed Chimney
Listed Termination Cap
Storm Collar
Flashing
Figure 13.1 - Prefabricated Interior Chimney
Thimble
Siteconstructedformasonrychimneyinstallation:
Components
A minimum length of 12 inches [305mm] (longer for
thicker walls) of solid insulated factory-built chimney
lengthconstructedtoUL103TypeHT6inch(152mm)
insidediameter.Chimneyneedstoextendaminimum
of2inches(51mm)fromtheinteriorwallandaminimum
of1inch(25mm)fromtheexteriorwall.
Wall spacer, trim collar and wall band to t solid pack
chimneyselected.
Minimum8inch(203mm)diameterclaylinersection(if
notalreadypresentinchimney)andrefractorymortar.
When jurisdiction requires install approved chimney
linerinmasonrychimney.
Air Clearances
•MasonrychimneyclearancemustmeetNFPA211mini-
mumrequirementof2inches(51mm)tosheetmetalsup-
portsandcombustibles.
•Minimumof1inch(25mm)clearancearoundthe chim-
neyconnector.
•Top of wall opening is a minimum of 13-1/2 inches
(343mm) from ceiling or 4-1/2 inches (114mm) below
minimum clearance specied by chimney connector
manufacturer.NFPA211minimumverticalclearanceof
18inches(457mm)fromchimneyconnectorandceiling
orminimumrecommendedbychimneyconnectormanu-
facturer.Figure 13.2
Instructions:
1. Openinsidewallatproperheightforthechimneycon-
nectortoentrythemasonrychimney. Figure 13.2
2. Entryholetomasonrychimneymustbelinedwithan8
inch (203mm) minimum diameter clay liner, or equiva-
lent,securedwithrefractorymortar.
3. Constructa17inchx17inch(432mmx432mm)outside
dimensionframefrom2x2framinglumbertotintowall
opening.Insideopeningofframeshouldbenolessthan
14inchx14inch(356mmx356mm).Figure 13.2
4. Attachthewallspacertothechimneysideoftheframe.
5. Nailtheframeintothewallopening.Thespacershould
beonthechimneyside.
6. Insertthesectionofthesolidinsulatedchimneyintothe
outerwallofthemasonrychimney.
7. Tightlysecurethelengthofthesolidinsulatedchimney
withthewallbandtothemasonrychimney.
8. Insertasectionofchimneyconnectorintothechimney.
Makesureitdoesnotprotrudepasttheedgeoftheclay
chimneylinerinsidethechimney.
9. Sealtheendofthechimneyconnectortotheclayliner
withrefractorymortar.
10.
Installtrimcollararoundthesoldpackchimneysection
.
Figure 13.2
1.5”
1.0”
2.0”
2.0”
1.5”
14.0” ID
17.0” OD
ceiling
Minimum18.0”
NFPA 211
13.5” below ceiling to top
of opening
1.0”
8.0”
1.5 2x2 framing stud
2.0 min air clearance
1.0 min air clearance
4.5
or top of opening is a min.of
4.5” below min.clearance
specified by connector mfg.
Center of Hole
Thimble
C
L
C
L
Wall
Include depth
of hearth pad
14 7033-328C May 09, 2017
3100 Millennium Wood Appliance
Trim Collar
Chimney Section
with 2 inch
(51mm)
Clearance to
Combustibles
Chimney
Connector
Fire Clay Flue
Liner
with Airspace
Masonry
Chimney
Wall Band to
Secure Chimney
Section
Wood Studs Used
for Framing - Spaced
2 inch (51mm)
clearance from
Masonry Chimney
Wall Spacer
Solid Pack Chimney with Metal Supports as a Thimble
Figure 14.1
Fire Risk.
DoNOTpackinsulationorothercombustiblesbetween
spacers.
• ALWAYSmaintainspeciedclearancesaroundvent-
ingandspacers.
• Installspacersasspecied.
Failuretokeepinsulationorothermaterialawayfromventpipe
maycausere.
WARNING
Flue Gas
Direction
Crimped
End
Toward
Appliance
Secure pipe sections with a
minimum of 3 screws
Figure 14.3 Chimney Connector (Appliance Pipe)
WARNING
ONLYuseconnector:
• Withintheroom,betweenapplianceandceilingorwall.
ConnectorshallNOTpassthrough:
• Atticorroofspace
• Closetorsimilarconcealedspace
• Floororceiling
Maintainminimumclearancestocombustibles
Fire Risk.
FollowChimneyConnectorManufacturer’s
InstructionsforProperInstallation.
Chimney Flue
Liner
Fireclay
Liner or
Equivalent
Masonry Chimney
Constructed to NFPA 211
Wall Spacer
Wall Band
Trim Collar
Chimney
Connector
1 inch (25mm) Air
Space to Chimney
Section
Min. Clearance
2 inch (51mm)
Min. Chimney Clearance to
Wall Spacer and
Combustibles - 2 inch (51mm)
Chimney Section
Figure 14.2
Solid Pack Chimney with Metal Supports as a Thimble
(Cont’d)
G. Installing Chimney Components
Chimney Connector
Singlewallconnectororappliancepipe.
Thismustbeatleast24gaugemildsteelor26gaugeblue
steel.Thesectionsmustbeattachedtotheapplianceand
toeach other withthecrimped(male)endpointingtoward
theappliance.Alljoints,includingtheconnectionattheue
collar,shouldbesecuredwith3sheetmetalscrews.Make
sure to follow the minimum clearances to combustibles.
Wherepassagethroughthewall,orpartitionofcombustible
constructionisdesiredinCanada,theinstallationshallcon-
formtoCAN/CSA-B365.
Factory-builtlistedchimneyconnector(vented).
A listed connector (vented) must be used when installing
thisapplianceinamobilehome.Thelistedconnectorsmust
conformtoeachothertoensureapropertandseal.
H. Proper Draft
TobesurethatyourQuadra-Fireinsertburnsproperly,the
chimneydraft(staticpressure)shouldbeapproximately-0.10
inches water column (W.C.) during a high burn and -0.04
inchesW.C.duringalowburn,measured6inches(152mm)
abovethetopoftheinsertafteronehourofoperationateach
burnsetting.
May 09, 2017 7033-328C 15
3100 Millennium Wood Appliance
Figure 15.1 - Floor & Rear Installation
Flex Line
Wire Tie
Wire Tie
Flex Adapter
Termination
Cap
For Floor Installa-
tions Remove
Circular “Knock-Out”
in Base of Pedestal.
Figure 15.2
Cover
Plate
Rope to Seal
Pedestal
Items Needed for Installation (not supplied)
• 4inchexaluminumpipe,orifusingalternatematerial,
thenitshallbemadefromdurable,non-combustible,heat
resistantmaterialupto350
o
F.Cutthepipetotherequired
lengthforyourinstallation.
•Phillipsheadscrewdriver
•Siliconesealant
•Drillsandsawsnecessaryforcuttingholesthroughthe
wallorooringinyourhome.
1. Removeallmaterialsfrompackingbox.
2. Usinga#2Phillipsscrewdriverattachtheexadapterto
theapplianceusing4screws.Figure 15.1
3. For oor installations, r
emove circular” knock-out” in the
baseofthepedestal.
4. Floor & Rear Installation:Cuta4inch(102mm)holein
outsidewalloroortoaccommodateoutsideairpiping.
Use4inch(102mm)aluminummetalexorrigidpiping
todirectlyconnectoutsideairtoapplianceintake.Use
thesuppliedterminationcapwitharodentscreen.Seal
betweenthewall(oroor)andthepipewithsiliconeto
preventmoisturepenetration.
5. Floor Installation Alternative: Insomeinstancesyou
maynotbeabletoinstalltheexpipeasshowinFigure
A. Outside Air Kit Installation
Asource of air(oxygen) is necessaryin order forcombus-
tion to take place. Whatever combustion air is consumed
bytheremustbereplaced.Airisreplacedviaairleakage
aroundwindowsandunderdoors.Inhomesthathavetightly
sealeddoorsandwindows,anoutsideairsourceisneeded.
AnoptionalOutsideAirKitisavail
able.
WARNING
Fire Risk.
Asphyxiation Risk.
Donotdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
• Closeproximitytoexhaustventsorchimneys
Fumesorodormayresult
Asphyxiation Risk.
Outsideairinletmustbelocatedtopreventblockage
from:
• Leaves
• Snoworice
• Otherdebris
Blockmaycausecombustionairstarvation
Smokespillagemaysetoffalarmsorirritatesensitive
individuals.
WARNING
Asphyxiation Risk.
LengthofoutsideairsupplyductshallNOTexceed
thelengthoftheverticalheightoftheexhaustue.
Firewillnotburnproperly
Smokespillageoccurswhendoorisopeneddue
toairstarvation.
WARNING
Included in OAK-ACC: Termination cap, (2) wire ties, flex
adapter,andfasteners
Included in SRV7033-041:Cover plate and sealing rope (see
Floor InstallationAlternative below,
Figure 15.2)
15.1.Ifthatisthecase,youwillneedtoorderSRV7033-
041which includes acover plate andsealing rope as
showninFigure 15.2.Thegoalistosealthepedestal
sonoroomaircanleakintothepedestalorforcoldair
inltration.
5 Appliance Set-Up
16 7033-328C May 09, 2017
3100 Millennium Wood Appliance
B. Door Handle Assembly
Figure 16.1
Install spring handle using a counter-clockwise motion until the
springhandlehasa2inchclearancefrombendofdoorhandrod
(Figure 16.1).
Tools Required:#2Phillipsheadscrewdriver
1.Locateboltssuppliedwiththeblower.
2.Alignholesinmountingangeofblowerwithboltholesin
appliance.Blowershouldbepositionedatbottomofrear
outerskinasshowninFigure 16.2
3.Re-insert and tighten bolts, securing blower onto outer
wallofappliance.
Shock Risk.
• DoNOTremovegroundingprongfromplug.
• Routecordawayfromappliance.
DoNOTroutecordunderorinfrontofappliance.
• Plugdirectlyintoproperlygrounded3prongreceptacle.
CAUTION
Figure 16.2
MANUAL:
Over-rides
the Snap
Disc
AUTO: Fan
will turn
ON/OFF
Automatically
by the Snap
Disc
Controls
the Fan
Speed
Snap Disc
Bracket
with Magnet
MANUAL
FAN
AUTO
LOW
HIGH
OFF
Secure wires
with wire tie
Secure blower
with 3 bolts
4.
Place the bracket containing the snap disc and magnet
underthebottomleftrearcorner.
SeeOwners Manualfordetailedoperatinginstructions
fortheblowerandsnapdisc.
C. Blower (Optional)
Door Handle
Spring
Handle
2 inch (51mm) clearance
required from bend in door
handle rod to end of spring
handle.
May 09, 2017 7033-328C 17
3100 Millennium Wood Appliance
CAUTION
THESTRUCTURALINTEGRITYOFTHEMOBILEHOME
FLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINED
DoNOTcutthrough:
• Floorjoist,wall,studsorceilingtrusses.
• Anysupportingmaterialthatwouldaffectthestructuralinteg-
rity.
NEVERINSTALLINASLEEPINGROOM.
Consumesoxygenintheroom.
WARNING
Asphyxiation Risk.
1. AnoutsideairinletmustbeprovidedforcombustionSee
page 15forinstallationinformation.
2. Appliancemustbesecuredtothemobilehomestructure
byboltingthepedestalthroughhearthpadandintooor.
3. Appliance must be grounded with #8 solid copper
groundingwireorequivalentandterminatedateachend
withN.E.C.approvedgroundingdevice.
4. AppliancemustbeinstalledwithanapprovedUL103HT
ventilated chimney connector, UL103 HT chimney, and
terminalcapwithsparkarrestor.Neveruseasinglewall
connector(appliancepipe)inamobilehomeinstallation.
Use only double-wall connector pipe, Dura-Vent DVL,
Selkirk Metalbestos DS or Security DL double-wall
connectororanylisteddouble-wallconnectorpipe.
5.
InCanada,thisappliance mustbeconnectedtoa6inch
(152mm) factory-built chimney conforming to CAN/ULC-
629M,STANDARDFORFACTORYBUILTCHIMNEYS.
6. Followthechimneyandchimneyconnectormanufacturer’s
instructionswheninstallingtheuesystemforuseina
mobilehome.
7. Maintainclearancetocombustibles.
8. Floorprotectionrequirementsmustbefollowedprecisely.
9. Use silicone to create an effective vapor barrier at the
locationwherethechimneyorothercomponentpenetrates
totheexteriorofthestructure.
NOTE: Offsets from the vertical, not exceeding 45°, are
allowedperSection905(a)oftheUniformMechanicalCode
(UMC).Offsetsgreaterthan45°areconsideredhorizontaland
arealsoallowed,providingthehorizontalrundoesnotexceed
75%oftheverticalheightofthevent.Construction,clearance
andterminationmustbeincompliancewiththeUMCTable
9C.ThisinstallationmustalsocomplywithNFPA211.
NOTE:Topsectionsofchimneymustberemovabletoallow
maximumclearanceof13.5feet(411cm)fromgroundlevel
fortransportationpurposes.
10. Burn wood only. Other types of fuels may generate
poisonousgases(e.g.,carbonmonoxide).
11. Ifapplianceburnspoorlywhileanexhaustblowerison
inhome,(i.e.,rangehood),increasecombustionair.
12. InstallationshallbeinaccordancewiththeManufacturers
Home&SafetyStandard(HUD)CFR3280,Part24.
You must use a Quadra-Fire Outside Air Kit Part
OAK-ACC and (depending on oor installation), Part
SRV7033-041 for installation in a mobile home.
6 Mobile Home Installation
18 7033-328C May 09, 2017
3100 Millennium Wood Appliance
7 Reference Materials
Date of Service Performed By Description of Service
May 09, 2017 7033-328C 19
3100 Millennium Wood Appliance
Service Parts
R
31M-ACC
Beginning Manufacturing Date: July 2006
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for
your appliance please provide model number and serial number. All parts listed in this manual may
be ordered from an authorized dealer.
Stocked
at Depot
ITEM DESCRIPTION COMMENTS PART NUMBER
Blower, Convection - Replacement Blower 812-4900
Y
Hinge Pins, 1/2”, Gold
Pre SN 0071959142
832-0250
Hinge Pins, 1/2”, Nickel SRV430-5320
Hinge Pins, 1/2”, Black
Post SN 0071959142
7000-606/2
Logo, Quadra-Fire
Gold 200-3180
Nickel 200-3240
Spring Handle, 1/2”, Gold
Pre SN 0071959142
832-0620 Y
Spring Handle, 1/2”, Nickel 250-8330 Y
Spring Handle, 1/2”, Black
Post SN 0071959142
SRV7000-613 Y
Spring Handle, 1/4”, Gold
Pre SN 0071959142
832-0630 Y
Spring Handle, 1/4”, Nickel 250-8340 Y
Spring Handle, 1/4”, Black
Post SN 0071959142
SRV7000-614 Y
Component Pack (Includes Touch-Up Paint, Spring Handles (1)
1/2” and (2) 1/4”, Trimount Plug, Owners Manual and Warranty
Card).
Black & Gold Trim
7033-027
Nickel Trim 7033-029
Paint Touch-Up 812-0910
Plug, Trimount, .250” Pkg of 24 229-0880/24
Y
Door Handle Assembly 832-0540
Y
Upgrade, Door, Nickel UK-DRNL
Gasket, Manifold Pkg of 4 7038-168/4
Y
ACCESSORIES
Blower Assembly BK-ACC
Blower Control Box w/Switch SRV7000-194 Y
Component Pack 7033-051
Snap Disc Bracket Assembly SRV7033-036
Snap Disc, # 1, Convection Blower SRV230-0470 Y
Wire Harness, Blower 7033-262
Outside Air Kit, Floor & Rear OAK-ACC
Outside Air Collar Assembly 7033-039
Outside Air Shield 33271
Y
Outside Air Cover Plate Assembly SRV7033-041
Y
FASTENERS
Avk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tools RIVNUT-REPAIR
Y
Bolt, Hex Head, 1/4-20 x 1 Pkg of 10 25221A/10
Y
Button Head 1/4-20 x .5 Pkg of 20 32328/20
Y
Nut, Keps Lock, 10-32 Pkg of 40 226-0050/40
Y
Nut, Keps Lock, 8-32 Pkg of 40 226-0060/40
Y
Nut, Ser Flange Small 1/4-20 Pkg of 24 226-0130/24
Y
Screw, Sheet Metal #8 x 1/2 S-Grip Pkg of 40 12460/40
Y
Washer, 1/4 Sae Pkg of 24 28758/24
Y
Service Parts
R
31M-ACC
Beginning Manufacturing Date: July 2006
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for
your appliance please provide model number and serial number. All parts listed in this manual may
be ordered from an authorized dealer.
Stocked
at Depot
ITEM DESCRIPTION COMMENTS PART NUMBER
Blower, Convection - Replacement Blower 812-4900
Y
Hinge Pins, 1/2”, Gold
Pre SN 0071959142
832-0250
Hinge Pins, 1/2”, Nickel SRV430-5320
Hinge Pins, 1/2”, Black
Post SN 0071959142
7000-606/2
Logo, Quadra-Fire
Gold 200-3180
Nickel 200-3240
Spring Handle, 1/2”, Gold
Pre SN 0071959142
832-0620 Y
Spring Handle, 1/2”, Nickel 250-8330 Y
Spring Handle, 1/2”, Black
Post SN 0071959142
SRV7000-613 Y
Spring Handle, 1/4”, Gold
Pre SN 0071959142
832-0630 Y
Spring Handle, 1/4”, Nickel 250-8340 Y
Spring Handle, 1/4”, Black
Post SN 0071959142
SRV7000-614 Y
Component Pack (Includes Touch-Up Paint, Spring Handles (1)
1/2” and (2) 1/4”, Trimount Plug, Owners Manual and Warranty
Card).
Black & Gold Trim
7033-027
Nickel Trim 7033-029
Paint Touch-Up 812-0910
Plug, Trimount, .250” Pkg of 24 229-0880/24
Y
Door Handle Assembly 832-0540
Y
Upgrade, Door, Nickel UK-DRNL
Gasket, Manifold Pkg of 4 7038-168/4
Y
ACCESSORIES
Blower Assembly BK-ACC
Blower Control Box w/Switch SRV7000-194 Y
Component Pack 7033-051
Snap Disc Bracket Assembly SRV7033-036
Snap Disc, # 1, Convection Blower SRV230-0470 Y
Wire Harness, Blower 7033-262
Outside Air Kit, Floor & Rear OAK-ACC
Outside Air Collar Assembly 7033-039
Outside Air Shield 33271
Y
Outside Air Cover Plate Assembly SRV7033-041
Y
FASTENERS
Avk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tools RIVNUT-REPAIR
Y
Bolt, Hex Head, 1/4-20 x 1 Pkg of 10 25221A/10
Y
Button Head 1/4-20 x .5 Pkg of 20 32328/20
Y
Nut, Keps Lock, 10-32 Pkg of 40 226-0050/40
Y
Nut, Keps Lock, 8-32 Pkg of 40 226-0060/40
Y
Nut, Ser Flange Small 1/4-20 Pkg of 24 226-0130/24
Y
Screw, Sheet Metal #8 x 1/2 S-Grip Pkg of 40 12460/40
Y
Washer, 1/4 Sae Pkg of 24 28758/24
Y
8 Accessory List
20 7033-328C May 09, 2017
CONTACT INFORMATION
Hearth & Home Technologies
352 Mountain House Road
Halifax, PA 17032
Division of HNI INDUSTRIES
Please contact your Quadra-Fire dealer with any questions or concerns.
For the number of your nearest Quadra-Fire dealer
log onto www.quadrafire.com
DO NOT DISCARD THIS MANUAL
CAUTION
Important operating and
maintenance instruc-
tions included.
Leave this manual with
party responsible for use
and operation.
Read, understand and
follow these instruc-
tions for safe installa-
tion and operation.
DO NOT
DISCARD
We recommend that you record the following pertinent
information for your heating appliance.
Date purchased/installed:_________________________________________________________________________
Serial Number:____________________________________ Location on appliance:___________________________
Dealership purchased from:________________________________________ Dealer phone:_1(_____)_____-______
Notes:________________________________________________________________________________________
______________________________________________________________________________________________
______________________________________________________________________________________________
______________________________________________________________________________________________
This product may be covered by one or more of the following patents: (United States) 5341794, 5263471, 6688302, 7216645, 7047962
or other U.S. and foreign patents pending.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Quadrafire 3100 Millennium ACC Install Manual

Type
Install Manual

Quadrafire 3100 Millennium ACC is a high-efficiency wood-burning appliance that provides warmth and ambiance to your home. With its advanced design and construction, the appliance is easy to install and operate, and it meets the latest environmental standards.

The 3100 Millennium ACC features a large viewing area, providing a captivating view of the flames. The appliance is also equipped with a variable-speed blower, which allows you to adjust the heat output to your desired comfort level.

The appliance is constructed of heavy-duty materials, including a cast iron firebox and a welded steel body. This ensures durability and long-lasting performance. The appliance is also dilengkapi with a durable ceramic glass door, which provides a clear view of the fire and helps to keep heat in.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI