Sinclair SDM-01 is a door controller that enables the use of a gate-control card to automatically turn on or off an air conditioning unit when someone enters or leaves a room, helping to save energy. The device is compatible with indoor units that have a gate-control function and can be controlled via a remote controller or buttons on the unit itself. The door controller can be installed in a concealed location and operates on either AC 220-240V, 50HZ or DC +5V-+24V power. It has a working temperature range of -10 to 48°C and a power consumption of 1W.

Sinclair SDM-01 is a door controller that enables the use of a gate-control card to automatically turn on or off an air conditioning unit when someone enters or leaves a room, helping to save energy. The device is compatible with indoor units that have a gate-control function and can be controlled via a remote controller or buttons on the unit itself. The door controller can be installed in a concealed location and operates on either AC 220-240V, 50HZ or DC +5V-+24V power. It has a working temperature range of -10 to 48°C and a power consumption of 1W.

INSTALLATION AND
OPERATION MANUAL
SDM-01
DOOR CONTROLLER
Instruction to door controller SDM-01
1. Gate-control Function
This SDM-01 door controller is only suitable for indoor unit with gate-control function. The AC will run after plugging in
gate-control card and stop running after plugging out the card. Upon plugging out the card to stop the unit, the running
states of the unit will be memorized. After plugging in the card, the unit will be under standby state or resume running
according to settings. The AC will run when the customer plugs in the card and automatically stop when he plugs out the
card, which ensures unit off after leaving of persons and saves energy.
Fig.1 is about simple sketch for communication network of door controller SDM-01.
Fig.1 Communication Network of Door Controller SDM-01
2. Working Process of Gate Control
1) If the gate-control card is not plugged in after powering on the complete unit, the indoor unit will be in the state without
gate-control function and can be operated by remote controller or buttons on it.
2) Powering on the AC and plugging in the card, the unit will be in the state with gate-control function after 5-second
detection. The present running state of the AC won’t be affected (the unit on/off state will be kept) after plugging in the card.
If plugging out the card, the AC will automatically stop after 5-second detection.
Once plugging in the card, indoor unit will be considered as the one with gate-control function, which can be canceled only
after powering off and then powering on the unit.
3. Door Controller SDM-01 Interface Sketch is shown in Fig.2:
Fig2: Detection Control Board Interface Sketch
The gate-control function can be realized after the detective interface of door controller SDM-01 connects with interface of
gate-control card and signal interface of it connects with the mainboard.
4. Products Parameters
Model: SDM-01 Door Controller
Working Voltage: AC 220-240V, 50HZ or DC +5V-+24V
Power: 1W
Working temperature: -10 48°C
5. Installation of the SDM-01 Door Controller
Fig. 3 Installation Sketch of Door controller SDM-01
Note: Door controller SDM-01 with (L×W×H) 73.5mm×73.5mm×33.0mm
Fig.3 is about installation process of door controller SDM-01. The following items should be attended.
1. Installation must be performed by professionals. Either 220-240V or DC 5-24V is ok.
2. Cut off the power of heavy current wire covered in the mounting hole in the wall before installation. Never perform the
installation with electricity.
3. Press the bottom plate of the door controller SDM-01 on the wall, and then make it and front panel of door controller
SDM-01 together.
4. At last fix the bottom plate and front panel of door controller SDM-01 together with screw ST2.2X6.5.
5. There shouldnt be any large-power electric appliance and firming base nearby to avoid interference source.
6. Avoid sunlight and rain and do not install it at wet space.
7. Do not install the unit at the place where there is corrosive gas, serious dust, salt fog and oil smoke or which is specially
wet.
8. The door controller SDM-01 must be installed at concealed place and far from water and fire.
No.
1
2
3
4
Description
Base box of socket installed in
the wall , a hole with( L×W×D
100mm×100mm×50mm
Bottom plate of
door controller
SDM-01
Front panel of door
controller SDM-01
Screw M4X25
Take-back of electrical waste
Information for Users to Disposal of electrical and electronic equipment
(private households)
Icon on the product or in the accompanying documentation means that used electric or electronic products
must not be disposed together with domestic waste. For the correct disposal of the product hand it over to a
place for take-back, where it is collected free of charge. By correct disposal of the product you can help to
preserve valuable natural resources and help in preventing potential negative impacts to environment and
human health, which could be consequence of incorrect disposal of waste. Ask for more details from local
authorities, nearest collection point, in Waste Acts of respective country, in the Czech Republic in Act no.
185/2001 Coll., in the wording of later regulations. In case of incorrect disposal of this waste, a fine can be
imposed according to national regulations.
Manufacturer:
Sinclair Corporation Ltd., 1-4 Argyll Street,
London W1F 7LD, UK
Supplier and technical support:
Nepa, spol.s.r.o.
Purkyova 45
612 00 Brno
Czech Republic
www.nepa.cz
Toll-free info line:
+420 800 100 285
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Sinclair SDM-01 User manual

Type
User manual

Sinclair SDM-01 is a door controller that enables the use of a gate-control card to automatically turn on or off an air conditioning unit when someone enters or leaves a room, helping to save energy. The device is compatible with indoor units that have a gate-control function and can be controlled via a remote controller or buttons on the unit itself. The door controller can be installed in a concealed location and operates on either AC 220-240V, 50HZ or DC +5V-+24V power. It has a working temperature range of -10 to 48°C and a power consumption of 1W.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI