OWNER’S MANUAL OM-154 299H
2010−05
Use above FORM number when ordering extra manuals.
RCC-5 And RCC-14
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols or
explained in the text.
Beware of electric shock from wiring. Disconnect input
power before installing this kit. Reinstall all panels and
covers.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible ha-
zards are shown in the adjoining symbols or explained in
the text.
Wear safety glasses with side shields.
NOTICE
Indicates statements not related to personal injury.
Indicates special instructions.
CALIFORNIA PROPOSITION 65 WARNINGS
Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and,
in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)
This product contains chemicals, including lead, known to the state of California to cause cancer, birth defects, or other reproductive harm.
Wash hands after use.
SECTION 1 − INSTALLATION AND OPERATION
. The RCC (Rotary Current And Contactor Control) is equipped with a 14-pin or a 5-pin plug for connection to the welding power source. Contact
your local distributor for correct adapter if plug does not mate with receptacle on welding power source.
! Be sure remote control is
turned all the way off before
turning on or off the welding
power source.
1 RCC (Rotary Current And
Contactor Control)
2 Velcro Straps
3 Torch
Secure control to torch with velcro
straps.
4 14-Pin Or 5-Pin Plug PLG2
Connect PLG2 to matching recep-
tacle on welding power source as
follows: align keyway, insert plug,
and tighten threaded collar.
5 Current And Contactor
Control Actuator
Begin turning actuator in the In-
crease direction as shown to close
contactor, and energize the weld-
ing power source. Continue turn-
ing actuator to increase current
level up to that set on the welding
power source Current Control.
Turn actuator in the Decrease di-
rection as shown to reduce the cur-
rent output to zero, and turn off the
contactor.
Ref. 157 463-B
1
2
3
4
5
Increase
Decrease
Figure 1-1. Installing And Operating An RCC Control