ADJ PAR Z100 5K User manual

Category
Floodlights
Type
User manual

ADJ PAR Z100 5K is a DMX intelligent, zooming, LED par fixture designed for theaters, studios, retail stores, and other similar locations. It features 4 DMX channel modes, RDM protocol support, 6 dimmer curve modes, a digital display for address and function setting, gamma correction adjustment, dimming frequency adjustment, and multiple unit power linking capabilities. The PAR Z100 5K is suitable for use as a stand-alone fixture or as part of a larger lighting system.

ADJ PAR Z100 5K is a DMX intelligent, zooming, LED par fixture designed for theaters, studios, retail stores, and other similar locations. It features 4 DMX channel modes, RDM protocol support, 6 dimmer curve modes, a digital display for address and function setting, gamma correction adjustment, dimming frequency adjustment, and multiple unit power linking capabilities. The PAR Z100 5K is suitable for use as a stand-alone fixture or as part of a larger lighting system.

User Instructions
©2018 ADJ Products, LLC all rights reserved. Information,
specications, diagrams, images, and instructions herein are
subject to change without notice. ADJ Products, LLC logo and
identifying product names and numbers herein are trademarks
of ADJ Products, LLC. Copyright protection claimed includes all
forms and matters of copyrightable materials and information
now allowed by statutory or judicial law or hereinafter granted.
Product names used in this document may be trademarks or
registered trademarks of their respective companies and are
hereby acknowledged. All non-ADJ Products, LLC brands and
product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby dis-
claim any and all liabilities for property, equipment, building,
and electrical damages, injuries to any persons, and direct or
indirect economic loss associated with the use or reliance of
any information contained within this document, and/or as a
result of the improper, unsafe, unsucient and negligent as-
sembly, installation, rigging, and operation of this product.
Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment.
Please turn o all electrical products when they are not in use. To
avoid power consumption in idle mode, disconnect all electrical
equipment from power when not in use. Thank you!
PAR Z100 5K
DOCUMENT VERSION
Please check www.adj.com for the latest revision/update of this guide.
1
Initial Release
01/02/18
2
1.2
1/2/3/4
Added: RDM Protocol Support, 4 CH DMX
Mode, Stage 2 Dimmer Curve, & Default
Settings System Menu
09/27/17
Date
Document
Version
Software
Version >
DMX
Channel
Mode
1.0
1/2/3
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 3ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 2
DMX-512 & RDM Protocol Support (4 DMX Channel Modes:
1 Channel, 2 Channels, 3 Channels & 4 Channels)
5-Pin XLR In/Out Connections
powerCON In/Out Connections
6 Dimmer Curve Modes
Digital Display for Address and Function Setting
Gamma Correction Adjustment
Dimming Frequency Adjustment
Multiple Unit Power Linking (See page 19)
Par Z100 5K Features
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures
warranty. In the unlikely event your unit may require service please
contact ADJ Products, LLC.
During operation the housing may become extremely hot. Avoid
touching the unit with bare hands while in use.
ADJ Products, LLC will not accept any liability for any resulting dam-
ages caused by the non-observance of this manual or any unauthor-
ized modication to this unit.
Par Z100 5K Handling Precautions
Par Z100 5K Warranty Registration
The Par Z100 5K carries a 2 year (730 days) limited warranty. Please
fill out the enclosed warranty card to validate your purchase and war-
ranty. You may also register your product online at www. adjproducts.
com. All returned service items whether under warranty or not, must
be freight pre-paid and accompany a return authorization (R.A.) num-
ber. If the unit is under warranty you must provide a copy of your
proof of purchase invoice. Please contact ADJ Products, LLC customer
support for a R.A. number.
To optimize the performance of this product, please read these
operating instructions carefully to familiarize yourself with the basic
operations of this unit. These instructions contain important safety
information regarding the use and maintenance of this unit. Please
keep this manual with the unit, for future reference.
Par Z100 5K General Instructions Par Z100 5K General Information
Unpacking: Thank you for purchasing the Par Z100 5K by ADJ Products,
LLC. Every Par Z100 5K has been thoroughly tested and has been
shipped in perfect operating condition. Carefully check the shipping
carton for damage that may have occurred during shipping. If the
carton appears to be damaged, carefully inspect your xture for any
damage and be sure all equipment necessary to operate the unit has
arrived intact. In the event damage has been found or parts are miss-
ing, please contact our toll free customer support number for further
instructions. Please do not return this unit to your dealer without con-
tacting customer support rst.
Introduction: The Par Z100 5K is a DMX intelligent, zooming, LED
par fixture. The Par Z100 5K operates as a stand alone fixture. This
fixture is suitable for theaters, studios, retail stores, and other similar
locations. For best results use fog or special effects smoke to enhance
the beams projections.
Customer Support: ADJ Products, LLC provides a toll free cus-
tomer support line, to provide help and to answer any question should
you encounter problems during your set up or initial operation. You
may also visit us on the web at www.adj.com for any comments or
suggestions. Service Hours are Monday through Friday 8:00 a.m. to
4:30 p.m. Pacic Standard Time.
Voice: (323) 582-2650
Fax: (323) 582-2941
E-mail: support@americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
Do not spill water or other liquids into or on to your unit.
Be sure that the local power outlet match that of the required volt-
age for your unit.
Do not attempt to operate this unit if the power cord has been
frayed or broken.
Do not attempt to remove or break o the ground prong from
the electrical cord. This prong is used to reduce the risk of electrical
shock and re in case of an internal short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user
serviceable parts inside.
Never operate this unit when it’s cover is removed.
Always be sure to mount this unit in an area that will allow proper
ventilation. Allow about 6” (15cm) between this device and a wall.
Do not attempt to operate this unit, if it becomes damaged.
This unit is intended for indoor use only, use of this product out-
doors voids all warranties.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to cords at plugs, convenience recep-
tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by
the manufacturer. See page 20 for cleaning details.
Heat -This fixture should be situated away from heat sources such
as radiators, heat registers, stoves, or other appliances (including
amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when:
A. Objects have fallen, or liquid has been spilled into the appliance.
B. The appliance has been exposed to rain or water.
C. The appliance does not appear to operate normally or exhibits
a marked change in performance.
Par Z100 5K Safety Precautions
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 5ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 4
Power Supply: The ADJ Par Z100 5K contains a automatic voltage
switch, which will auto sense the voltage when it is plugged into the
power source. With this switch there is no need to worry about the cor-
rect power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of
communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX
fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models
of dierent manufactures to be linked together and operate from a
single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using
several DMX fixtures try to use the shortest cable path possible. The
order in which fixtures are connected in a DMX line does not influence
the DMX addressing. For example; a fixture assigned a DMX address
of 1 may be placed anywhere in a DMX line, at the beginning, at the
end, or anywhere in the middle. Therefore, the first fixture controlled
by the controller could be the last fixture in the chain. When a fixture
is assigned a DMX address of 1, the DMX controller knows to send
DATA assigned to address 1 to that unit, no matter where it is located
in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave
Operation): The Par Z100 5K can be controlled via DMX-512 proto-
col. The Par Z100 5K has four DMX channel modes; 1 channel mode,
2 channel mode, 3 channel mode, & 4 channel
mode. The DMX address is set electronically using
the controls on the rear panel of the unit. Your unit
and your DMX controller require a approved DMX-
512 110 Ohm Data cable for data input and data
output (Figure 1). We recommend Accu-Cable DMX
cables. If you are making your own cables, be sure
to use standard 110-120 Ohm shielded cable (This
cable may be purchased at almost all professional
Par Z100 5K DMX Set Up
Figure 1
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 6 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 7
5-Pin XLR DMX Connectors.
This unit use 5-pin DMX-512 data
cables for DATA transmission. 5-pin DMX xtures may be implemented
in a 3-pin DMX line. When inserting standard 5-pin data cables in to
a 3-pin line a cable adaptor must be used, these adaptors are read-
ily available at most electric stores. The chart below details a proper
cable conversion.
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Pin 1
Pin 5 - Do Not Use
Pin 4 - Do Not Use
Pin 3
Pin 2
Pin 1
Pin 3
Pin 2
Not Used
Not Used
Data True (+ signal)
Data Compliment (- signal)
Ground/Shield
3-Pin XLR to 5-Pin XLR Conversion
Par Z100 5K DMX Set Up
sound and lighting stores). Your cables should be made with a male
and female XLR connector on either end of the cable. Also remember
that DMX cable must be daisy chained and cannot be split.
Par Z100 5K DMX Set Up
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OT
3-PIN XLR
Figure 2
Figure 3
1 Ground
1 Ground
XLR Male Socket
XLR Pin Conguration
3 Hot
2 Cold
2 Cold
3 Hot
XLR Female Socket
Pin 3 = Data True (positive)
Pin 2 = Data Compliment (negative)
Pin 1 = Ground
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OT
3-PIN XLR
Figure 4
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 9ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 8
Par Z100 5K System Menu
Par Z100 5K System Menu
System Menu: When making adjustments press ENTER to
conrm your setup then press and hold the MENU button
for at least 3 seconds. To exit without making any adjust-
ments press the MENU button. The display will lock after 30
seconds, press the MENU button for 3 seconds to unlock.
- DMX Address Setting.
1. Press either the MENU, UP, or DOWN buttons until
is displayed, press ENTER.
2. The current address will now be displayed and ashing.
Press the UP or DOWN buttons to nd your desired address.
Press ENTER to set your desired DMX address.
- This will let select your desired DMX channel
mode.
1. Press either the MENU, UP, or DOWN buttons until
is displayed, and press ENTER. The current DMX channel mode
will be displayed.
2. Press the UP or DOWN buttons to nd your desired DMX
channel mode and press ENTER to conm and exit.
Dimming frequency
Gamma correction
Manual mode
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 10
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 11
- With this function you can adjust the dimming
frequency.
1. Press either the MENU, UP, or DOWN buttons until is
displayed, and press ENTER.
2. Use the UP or DOWN buttons to adjust the dimming
frequency between 900hz, 1000hz, 1100hz, 1200hz, 1300hz,
1400hz, 1500hz, 2500hz, 4000hz, 5000hz, 10000hz, 15000hz,
20000hz, or 250000hz.
3. Once you have found your desired dimming frequency press
ENTER to conrm.
- In this menu you are able to make gamma
corrections.
1. Press either the MENU, UP, or DOWN buttons until is
displayed, press ENTER.
2. Use the UP or DOWN buttons to gamma corrections.
3. Once you have found your desired dimming frequency press
ENTER to conrm.
- This function will reverse the display 180º.
1. Press either the MENU, UP, or DOWN buttons until
is displayed, press ENTER.
2. Press the UP button to select “DSIP” to “ip” the display, or
DISP” to revert the display to normal.
3. Press ENTER to conrm.
Par Z100 5K System Menu
- This mode can be used as a precaution mode,
that in case the DMX signal is lost, interrupted, or power is
lost, the operating mode chosen in the setup is the running
mode the xture will go into when the DMX signal is lost. You
can also set this as the operating mode you would like the
unit to return to when power is applied.
1. Press either the MENU, UP, or DOWN buttons until is
displayed, and either “BLND or “HOLD will be displayed
beneath.
2. Press ENTER and the bottom choice will begin to ash. Use
the UP or DOWN buttons to choose an operating mode you
would like the unit to start up in when power is applied or the
DMX signal is lost.
BLND (Blackout) - If the DMX signal is lost or interrupted, the
unit will automatically go into stand by mode.
HOLD - If the DMX signal is lost the xture will stay in the last
DMX setting. If power is applied and this mode is set, the unit will
automatically go into the last DMX set up.
3. Press ENTER to conrm your desired set up.
- This will let select your desired dimmer curve.
1. Press either the MENU, UP, or DOWN buttons until is
displayed, and press ENTER. 1 of 6 dimmer curves will be
displayed. “STDA” (standard), “STG1” (Stage 1), “TV” (TV),
ARAL” (Architectural), “THAL” (Theatre), or “STG2” (Stage 2).
See the dimmer curve chart on page 18 for more info.
2. Press the UP or DOWN buttons to nd your desired dimmer
curve and press ENTER to conm and exit.
Par Z100 5K System Menu
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 12 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 13
- This function will allow you to manually adjust
each brightness, ne dimming, and strobing. Fine dimming
and strobing are only used with 3 channel mode.
1. Press either the MENU, UP, or DOWN buttons until is
displayed, press ENTER.
2. Use the UP and DOWN buttons to scroll through the settings.
Once you have found your desired function you would like to
adjust press ENTER.
3. After you have pressed ENTER, use the UP and DOWN buttons
to adjust the values. Once you have made your adjustments
press ENTER to set them. Press the MENU button to exit.
- This function will run a self test program.
1. Press either the MENU, UP, or DOWN buttons until is
displayed, press ENTER.
2. The xture will now run a self test. Press the MENU button to
exit and quit the self test.
- With this function you can check the temperature
of the xture.
1. Press either the MENU, UP, or DOWN buttons until is
displayed, press ENTER.
2. The xture temperature will now be displayed. Press MENU
to exit.
Par Z100 5K System Menu
- With this function you can display the running
time of the unit.
1. Press either the MENU, UP, or DOWN buttons until is
displayed, press ENTER.
2. The running time of the xture will now be displayed. Press
MENU to exit.
- Use this function to display the Software version
of the unit.
1. Press either the MENU, UP, or DOWN buttons until
is displayed, press ENTER.
2. The display will show the software version.
- Use this function to reset to default settings.
1. Press either the MENU, UP, or DOWN buttons until
is displayed, and press ENTER.
2. The display will show either “on” or “oFF”. Use the UP or
DOWN buttons to choose, and press ENTER. “On” will default
to factory settings. Press the MENU button to exit without
change.
Par Z100 5K System Menu
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 15ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 14
Universal DMX Control: This function allows you to use a uni-
versal DMX-512 controller to control the dimmer, fine dimmer and
strobe. A DMX controller allows you to create unique programs tai-
lored to your individual needs.
1. The Par Z100 5K has 4 DMX channel modes; 1 channel mode,
2 channel mode, 3 channel mode, 4 channel mode. See pages
16-17 for a detailed description of the DMX values and traits.
2. To control your fixture in DMX mode, follow the set-up procedures
on pages 5-7 as well as the set-up specifications that are included
with your DMX controller.
3. Use the controller’s faders to control the various DMX fixture traits.
4. This will allow you to create your own programs.
5. Follow the instructions on page 9 to select your DMX channel
mode and set your desired DMX address.
6. For longer cable runs (more than a 100 feet) use a terminator on
the last fixture.
7. For help operating in DMX mode consult the manual included
with your DMX controller.
Par Z100 5K DMX Operation Par Z100 5K Beam Angle Adjustment
To adjust the beam angle slide the beam angle adjuster located
inside/in front of the lens. See diagram below.
The beam angle can be adjusted manually, between / 15°/ 20°/25°/ 30°.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 16 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 17
Channel Value Function
1 DIMMER
0 - 255 0% - 100%
Par Z100 5K 1 Channel Mode
Channel Value Function
1 DIMMER
0 - 255 0% - 100%
2 SHUTTER/STROBE
0 - 31 LED OFF
32 - 63 LED ON
64 - 95 STROBING SLOW - FAST
96 - 127 LED ON
128 - 159 PULSE EFFECT
160 - 191 LED ON
192 - 223 RANDOM STROBE SLOW - FAST
224 - 255 LED ON
Par Z100 5K 2 Channel Mode
Channel Value Function
1 DIMMER
0 - 255 0% - 100%
2 0 - 255 DIMMING FINENESS
3 SHUTTER/STROBE
0 - 31 LED OFF
32 - 63 LED ON
64 - 95 STROBING SLOW - FAST
96 - 127 LED ON
128 - 159 PULSE EFFECT
160 - 191 LED ON
192 - 223 RANDOM STROBE SLOW - FAST
224 - 255 LED ON
Par Z100 5K 3 Channel Mode
Channel Value Function
1 DIMMER
0 - 255 0% - 100%
2 0 - 255 DIMMING FINENESS
3 SHUTTER/STROBE
0 - 31 LED OFF
32 - 63 LED ON
64 - 95 STROBING SLOW - FAST
96 - 127 LED ON
128 - 159 PULSE EFFECT
160 - 191 LED ON
192 - 223 RANDOM STROBE SLOW - FAST
224 - 255 LED ON
4 DIMMER MODE
0 - 20 STANDARD
21 - 40 STAGE
41 - 60 TV
61 - 80 ARCHITECTURAL
81 - 100 THEATRE
101 - 120 STAGE 2
121 - 255 DEFAULT DIMMER SETTING
Par Z100 5K 4 Channel Mode
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 18 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 19
Par Z100 5K Dimensional Drawings
10.82”/275mm
19.33”/491mm
8.8”/224mm
9.75”/248mm
4.44”/113mm
The unit should be mounted using a mounting clamp (not provided),
axing it to the mounting bracket that is provided with the unit.
Always ensure that the unit is rmly xed to avoid vibration and slip-
ping while operating. Always ensure that the structure to which you
are attaching the unit is secure and is able to support a weight of 10
times the unit’s weight. Also, always use a safety cable that can hold
12 times the weight of the unit when installing the xture.
The equipment must be installed by a professional, and it must be
installed in a place where it is out of the reach of people’s grasp.
Par Z100 5K Installation
Par Z100 5K Multiple Unit Power Linking
With this feature you can connect the xtures to one another
using the powerCON input and output sockets. The quantity that
can be connected is 15 xtures maximum @ 120V and 25 xtures
maximum @ 230V. After maximum xtures is met you will need to
use a new power outlet.
NOTE: USE CAUTION WHEN POWER LINKING OTHER
FIXTURES TO THE PAR Z100 5K AS THE POWER
CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
Par Z100 5K Dimmer Curve Chart
DIMMER
100%
50%
10%
0%
Time (ms)
0 Sec
255 255
0 0
Standard (default) 0 0 0 0
Stage 780 1100 1540 1660
TV 1180 1520 1860 1940
Architectural 1380 1730 2040 2120
Theatre 1580 1940 2230 2280
Stage 2
0 1100 0 1660
Rise Time (ms) Down Time (ms) Rise Time (ms) Down Time (ms)
Rise Time Down Time
Dimming Curve
Ramp Effect
0 sec Fade Time 1 sec Fade Time
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 20 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 21
Par Z100 5K Cleaning
Par Z100 5K Trouble Shooting
Trouble Shooting: Listed below are a few common problems that
you may encounter, with solutions.
No light output from the unit;
1. Be sure the external fuse has not blown. The fuse is located on
the rear panel of the unit.
2. Be sure the fuse holder is completely and properly seated.
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal optical lenses and mirror should be carried out periodically to
optimize light output. Cleaning frequency depends on the environ-
ment in which the fixture operates (I.e. smoke, fog residue, dust,
dew). In heavy club use we recommend cleaning on a monthly basis.
Periodic cleaning will ensure longevity, and crisp output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics with glass cleaner and a soft cloth every
20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every
30-60 days.
5. Always be sure to dry all parts completely before plugging the unit
back in.
Par Z100 5K Fuse Replacement
Unplug the unit from any power source it may be connected to. Once
the power has be disconnected, use a phillips head screw driver to
unscrew the fuse holder located above the powerCON input. Remove
the bad fuse and replace with a new one, and screw the fuse holder
back in.
Par Z100 5K Notes
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 22
Par Z100 5K Warranty
MANUFACTURER’S LIMITED WARRANTY
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products
to be free of manufacturing defects in material and workmanship for a prescribed period from
the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the
product is purchased within the United States of America, including possessions and
territories. It is the owners responsibility to establish the date and place of purchase by acceptable
evidence, at the time service is sought.
B. For warranty service you must obtain a Return Authorization number (RA#)
before sending back the product–please contact ADJ Products, LLC Service Department
at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All
shipping charges must be pre-paid. If the requested repairs or service (including
parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return
shipping charges only to a designated point within the United States. If the entire instrument is
sent, it must be shipped in it’s original package. No accessories should be shipped with the product. If
any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for
loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified in any
manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the
product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior
written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because
not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintnance, cleaning or periodic check
up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense
with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this
warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole
discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August
15, 2012, and bear indentifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products
without any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with
products described above. Except to the extent prohibited by applicable law, all implied warranties made
by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness,
are limited in duration to the warranty period set forth above. And no warranties, whether expressed or
implied, including warranties of merchantability or fitness, shall apply to this product after said period
has expired. The consumers and/or Dealers sole remedy shall be such repair or replacement as is
expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or
damage, direct or consequential, arising out of the use of, or inability to use, this product.
This warranty is the only written warranty applicable to ADJ Products, LLC Products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore
published.
MANUFACTURER’S LIMITED WARRANTY PERIODS:
•NonL.E.D.LightingProducts=1-year(365days)LimitedWarranty(Such as: Special Effect
Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par
Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
•LaserProducts=1Year(365Days)LimitedWarranty(excluding laser diodes which have a 6 month
limited warranty)
•L.E.D.Products=2-year(730days)LimitedWarranty(excluding batteries which have a 180 day lim-
ited warranty). Note:2YearWarrantyonlyappliestopurchaseswithintheUnitedStates.
•StarTecSeries=1YearLimitedWarranty(excluding batteries which have a 180 day limited war-
ranty).
•ADJDMXControllers=2Year(730Days)LimitedWarranty
Please Note: Specications and improvements in the design
of this unit and this manual are subject to change without any
prior written notice.
Par Z100 5K Specifications
Model: Par Z100 5K
Voltage: 100 - 240V, 50/60Hz
LED: 1 x 98W COB LED
Power Consumption: 115W
Power Linking: 15 Fixtures Max. @ 120V
25 Fixtures Max. @ 230V
Dimensions: 19.33”(L) x 10.82”(W) x 8.75”(H)
491 x 275 x 224mm (with Bracket)
Weight: 8 Lbs. / 3.6 kgs.
Beam Angle: 9/15/20/25/30 Degrees
Fuse: 3.15 Amp
Duty Cycle: None
DMX: 4 DMX Channel Modes: 1/2/3/4
Color Temperature: 5700K
Working Position: Any Safe, Secure Position
Warranty: 2 Year (730 days)
Auto Sensing Voltage: This xture contains a automatic volt-
age switch, which will auto sense the voltage when it is plugged
into the power source.
ADJ Products, LLC
6122 S. Eastern Ave. Los Angeles, CA 90040 USA
Tel: 323-582-2650 / Fax: 323-582-2941
www.adj.com / [email protected]
A.D.J. Supply Europe B.V.
Junostraat 2
6468 EW Kerkrade
Netherlands
www.adj.eu / [email protected]
Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

ADJ PAR Z100 5K User manual

Category
Floodlights
Type
User manual

ADJ PAR Z100 5K is a DMX intelligent, zooming, LED par fixture designed for theaters, studios, retail stores, and other similar locations. It features 4 DMX channel modes, RDM protocol support, 6 dimmer curve modes, a digital display for address and function setting, gamma correction adjustment, dimming frequency adjustment, and multiple unit power linking capabilities. The PAR Z100 5K is suitable for use as a stand-alone fixture or as part of a larger lighting system.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI