White Mountain Hearth Rushmore 50 Conversion Kit Natural Gas to Propane (38226) Owner's manual

Type
Owner's manual
40023-0-1118 Page 1
WARNING
This conversion kit must be installed by an Empire Comfort Systems distributor (or other
qualied agency¹)*in accordance with the manufacturers instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualied agency performing this work assumes
responsibility for this conversion.
1National Fuel Gas Code Z223.1 (Latest Edition)
*The term “qualied individual, rm, corporation or company which either in person or through
a representative is engaged in and is responsible for (a) the installation of gas piping or (b)
the connection, installation repair, or servicing of equipment, who is experienced in such
work, familiar with all precautions required, and has complied with all the requirements of the
authority having jurisdiction.
CHECK SAFETY SHUTDOWN PERFORMANCE
WARNING
Perform the safety shutdown test anytime work is done on a gas system to avoid the possibility
of re or explosion with property damage, personal injury or loss of life.
SAFETY SHUTDOWN SYSTEM
Intermittent Pilot System
1. Turn "OFF" using remote control. Main burner and pilot should go off.
2. Pilotgasowshouldstopwithin30seconds.
PARTS LIST
Part Description Conversion Kit Quantity Supplied
MainBurnerOrice,Front P210 1
MainBurnerOrice,Rear P308 1
SIT Gas Valve Conversion Kit R11382 1
Gas Conversion Label 1224 1
TOOLS NEEDED:
• StandardScrewdriver
• 1/4 Inch Hex Driver
• 5/16 Inch Hex Driver
• 7/16 Inch Wrench
• 7/16 Inch Deep
Socket Set
Gas input for direct-vent replace converted to Propane Gas: DVCT50CFP95N
Thedirect-ventgasreplacewhenconvertedtoPropaneGaswillhaveamanifoldpressureofapproximately
10.0inchesw.c.(2.49kPa)atthevalveoutletwiththeinletpressuretothevalvefromaminimumof10.8inchesw.c.
(2.68kPa)forthepurposeofinputadjustmenttoamaximumof14.0inchesw.c.(3.484kPa).
INSTALLATION INSTRUCTIONS
DIRECT VENT GAS FIREPLACE
FOR USE ON: DVCT50CFP95N CONVERSION KIT PART NUMBER 38226
FOR CONVERSION TO PROPANE GAS
40023-0-1118Page 2
INSTRUCTIONS FOR CONVERSION
1. Ifthereplaceisinstalled,turnOFFgasandelectricsupply
toreplacebeforemakinggasconversion.Allowreplaceto
cool completely.
2. Removebarrierscreen,glassdoor,logsandembers,and
liners(SeeHomeowner'sManualandLinerInstructions).
Figure 1
3. Removefrontandrearburnersbyremovingscrewsonleft
andpullingouttowardsleftside.See Figure 2.
Figure 2
.
4. Remove(2)screwsholdingpilotassemblytoburnerpan.
Thiswillallowpilotassemblytodrop.
5. Remove(2)screwsholdingburnerbaseinplace.Liftburner
baseoutofrebox.See Figure 4.
Figure 4
6. Use needle-nose pliers to remove targets and discard.
See Figure 5.
REAR
FRONT
Figure 5
7.
Use a 7/16 inch deep socket set to remove front and rear
orices.
8. Usea7/16inchdeepsocketsettoinstalloricemarked
"1.4"inrearoriceholderand"#51"infrontoriceholder.
REAR
FRONT
Figure 6
40023-0-1118 Page3
9.
Loosenrearairshutterscrewandrotatehandletotheright
untilfullopenisachievedandtightendownscrew.See Figure 7.
10.Repeatwithfront.
REAR AIR
SHUTTER
SCREW
FRONT AIR
SHUTTER
SCREW
CLOSED
OPEN
REAR
FRONT
Figure 7
11. Usinga7/16inchopenwrench,loosenpilotbodybyslightly
turningcounter-clockwise.Slideoricebrackettootherside
andtightenpilotbodyclockwise.See Figure 8.
“LP” MARKING
(HOLE, RED P
AINT)
Figure 8
12. Replaceitemsremovedinsteps2-5inreverseorder.
13. Turngasandelectricon.
14. Gas conversion completed.
Checkthemainburnerameandpilotburnerameforproper
amecharacteristics,asoutlinedintheInstallationInstructions
andOwner'sManual.
Ifreplaceisnotinstalledorproductregistrationcardhasnot
beenreturnedtoEmpireComfortSystem’s,checkofftypeof
gasconvertedtoonthecard.Alsoindicateconversionbyadding
“Conv.” behind type of gas.
40023-0-1118Page 4
www.empirecomfort.com
Empire Comfort Systems Inc.
Belleville, IL
If you have a general question
aboutourproducts,pleasee-mail
If you have a service or repair
question,pleasecontactyourdealer.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

White Mountain Hearth Rushmore 50 Conversion Kit Natural Gas to Propane (38226) Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI