Installation Guide
Fitting the Snap-Lock Sensor
1.Place the sensor onto the valve
Sensor horizontal:
ensuring that scale
pointer is at top.
Sensor vertical:
ensuring that the scale
pointer is at the front.
2.Press the sensor firmly on to valve until
snap-lock "clicks"
Positive SHUT-OFF feature:
The head can be turned past the setting (a
slight resistance will be felt) to setting "0" at
which point the water flow is shut off completely.
After also shutting the lockshield valve the radia-
tor may be drained and removed for maintenance
and decoration purposes.
Removing the Snap-Lock Sensor
1. Turn sensor to setting.
2. Hold outer ring whilst turning inner ring anti-clock-
wise to release snap-lock mechanism.
The sensor can now be separated from the valve.
Resetting the Snap-Lock
3. Having removed sensor from valve, ensure sensor
is set to .
4. Hold outer ring whilst turning arrow mark on inner
ring towards scale pointer until stop.
Inner ring Outer ring Scale pointer
User Guide
Setting the desired room temperatures
The desired room temperature is set by turning
the head. The temperatures obtained are ap-
proximately:
Lockshield valve (type RLV-D) is only included
in codes: 013G6102, 013G6103, 013G6104
Adjusting Temperature Control Range
Setting the upper limit:
e.g. IIII as the highest possible temperature selec-
tion:
1. Turn the head to max. position
2. Keep the limiter tab to the right of the scale
pointer pressed down with a small screwdriver.
3. Turn the head round to IIII and release the tab.
Setting the lower limit:
e.g. II as the lowest possible temperature selec-
tion:
1. Turn the head to min. position i.e. 0-positive
off.
2. Keep the limiter tab to the left of the black
scale pointer pressed down with a small
screwdriver.
3. Turn the head to II. You can now release the
tab.
Limiter tabs are located in the groove
Do not cover the thermostat
The thermostat opens and closes as determined
by the temperature around it. Therefore the sen-
sor must never be hidden behind thick curtains,
furniture, etc. Alternatively a thermostat with
remote sensor should be used.
Removal of
protective cap
Balancing
(This package contains sensor 013G5120/5022 and
valve 013G3281/3283 or 013G0084)