Vision Technology D410-TP22H33V12 User manual

Category
Security camera accessories
Type
User manual

Vision Technology D410-TP22H33V12 is a vandal-proof camera with a 1/3" 470k pixel CCD sensor and a resolution of 520 TV lines. It has a minimum illumination of 0.3 Lux and a shutter speed of 1/50~1/120,000sec. The camera also features built-in day/night functionality, which allows it to automatically switch between color and black-and-white modes depending on the lighting conditions. Other features include automatic white balance, backlight compensation, and digital noise reduction. The camera is powered by a 12V DC power supply and has a power consumption of 3.0 W.

Vision Technology D410-TP22H33V12 is a vandal-proof camera with a 1/3" 470k pixel CCD sensor and a resolution of 520 TV lines. It has a minimum illumination of 0.3 Lux and a shutter speed of 1/50~1/120,000sec. The camera also features built-in day/night functionality, which allows it to automatically switch between color and black-and-white modes depending on the lighting conditions. Other features include automatic white balance, backlight compensation, and digital noise reduction. The camera is powered by a 12V DC power supply and has a power consumption of 3.0 W.

COLOUR VANDAL PROOF CAMERA
D410-TP12H33V12
D410-TP22H33V12
Dimensions : mm
INSTRUCTION MANUAL
About this Manual
Before installing and using the camera, please read this manual
carefully. Be sure to keep it safe for later reference.
SPECIFICATION
PRECAUTIONS
D410-TP12H33V12 D410-
MODEL
General Spec
PAL
CCD Type
1/3" 470k Pixels
Color
Total number of pixels 795(H) X 596(V)
Min illumination
Video Output
Resolution
S/N Ratio
Shutter speed x128 : 1/50~1/120,000sec
Sync System
White Balance
OSD
Built-in
DAY / NIGHT
AUTO / EXTERN / B/W / COLOR
DNR LOW, MIDDLE, HIGH, OFF
Power Input
Video Output
Voltage
Power Consumption
Lens
Dimension
Weight
Case Color
Operation temp
In storage temp
Operation humidity
-10
Ԩ׽
+55
Ԩ
-20
Ԩ׽
+70
Ԩ
Under 90
(Non-condensing)
890g
Ivory
Max [DC12V : 3.0 W]
Mechanical Spec
3.3~12.0 mm / DC LENS
140(ø) X 105(H)mm
Wire
BNC Cable
Electric Spec
DC 12V ( 10.8V ~ 13.2V
)
50dB (AGC off, weight ON)
Internal / External
ATW/AWC/MANUAL (1800 ˚K ~ 10,500 ˚K)
Connectors
0.3 Lux/F1.2(50 IRE, AGC HIGH, DNR HIGH)
1.0Vp-p/75 ohm Composite
520 TV Lines(Min)
DC10-20V/ AC 20-28V 50Hz
Max ?W
Do not open or modify
Do not open the cabinet except during maintenance and
installation, as it may endanger you safety and cause damage.
Do not put objects inside the unit
Make sure that no metal objects or flammable substances get
inside the camera. It could cause fire, short-circuits or
damage.
Be careful when handling the unit
To prevent damage, do not drop the camera or subject
it to strong shock or vibration.
Install away from electric or magnetic fields
Protect from humidity and dust
Protect from high temperature
Be careful when installing close to the ceiling , in a kitchen or
boiler room, as the temperature may raise to high levels.
Always use the camera within its operating temperature range.
Cleaning
Dirt can be removed from the cabinet only by wiping it
with a soft cloth moistened with a soft detergent solution.
Mounting Surface
The mounting surface material must be strong enough to
secure the camera.
Ingress Protection
Ensure all cable entry points are sealed with silicone sealent
to prevent moisture ingress
CONNECTIONS
About this Manual
Before installing and using the camera, please read this manual
carefully. Be sure to keep it safe for later reference.
TROUBLESHOOTING
SPECIFICATION
Before sending the camera out for repair, check the items
below. If the problem persists after checking these items,
contact your service center.
If no image appears
Is the coaxial cable attached securely?
Are the power and voltage normal?
Has the iris of the lens inside the camera been
adjusted correctly (incorrect lens level) ?
Is there adequate illumination?
If the image is unclear
Is the lens in focus?
Is the lens dirty?
Dirt or fingerprints on the lens can adversely affect the
images. Gently wipe any dirt or fingerprints off the lens
with a soft cloth or lens cleaning paper and cleaning
fluid (commercially available).
Is the monitor adjusted correctly?
WARNING:
TO PREVENT THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE THE
INSIDE OF THIS APPLIANCE TO RAIN OR
MOISTURE. SEAL CABLE ENTRY POINTS TO
PREVENT MOISTURE FROM INTO THE
CAMERA.
CAUTION :
Check for polarity when using a DC 12V.
CONNECTOR AND CAMERA SETTING
INSTALLATION
PRECAUTIONS
DC12V AC24V
B
A
C
D
E F
D410-TP12H33V12 D410-
MODEL
General Spec
PAL
CCD Type
1/3" 470k Pixels
Color
Total number of pixels 795(H) X 596(V)
Min illumination
Video Output
Resolution
S/N Ratio
Shutter speed x128 : 1/50~1/120,000sec
Sync System
White Balance
OSD
Built-in
DAY / NIGHT
AUTO / EXTERN / B/W / COLOR
DNR LOW, MIDDLE, HIGH, OFF
Power Input
Video Output
Voltage
Power Consumption
Lens
Dimension
Weight
Case Color
Operation temp
In storage temp
Operation humidity
-10
Ԩ׽
+55
Ԩ
-20
Ԩ׽
+70
Ԩ
Under 90
(Non-condensing)
890g
Ivory
Max [DC12V : 3.0 W]
Mechanical Spec
3.3~12.0 mm / DC LENS
140(ø) X 105(H)mm
Wire
BNC Cable
Electric Spec
DC 12V ( 10.8V ~ 13.2V
)
50dB (AGC off, weight ON)
Internal / External
ATW/AWC/MANUAL (1800 ˚K ~ 10,500 ˚K)
Connectors
0.3 Lux/F1.2(50 IRE, AGC HIGH, DNR HIGH)
1.0Vp-p/75 ohm Composite
520 TV Lines(Min)
DC10-20V/ AC 20-28V 50Hz
Max ?W
Do not open or modify
Do not open the cabinet except during maintenance and
installation, as it may endanger you safety and cause damage.
Do not put objects inside the unit
Make sure that no metal objects or flammable substances get
inside the camera. It could cause fire, short-circuits or
damage.
Be careful when handling the unit
To prevent damage, do not drop the camera or subject
it to strong shock or vibration.
Install away from electric or magnetic fields
Protect from humidity and dust
Protect from high temperature
Be careful when installing close to the ceiling , in a kitchen or
boiler room, as the temperature may raise to high levels.
Always use the camera within its operating temperature range.
Cleaning
Dirt can be removed from the cabinet only by wiping it
with a soft cloth moistened with a soft detergent solution.
Mounting Surface
The mounting surface material must be strong enough to
secure the camera.
Ingress Protection
Ensure all cable entry points are sealed with silicone sealent
to prevent moisture ingress
1. Use the supplied L-wrench to remove the four fixing
screws (B) of dome cover (A).
2. Align the camera unit with the surface of the ceiling,
make marks on the ceiling in the places where the
screw holes are to be drilled, and then drill the four
holes.
3. Cut a hole (diameter2.9in.73mm) in the ceiling for
routing the cables.
4. Pass the power cable (E) and video cable (F) from the
camera unit through the cable hole in the ceiling.
5. Align the four screw holes in the camera unit (D) with
the screw holes in the ceiling, and then secure the
camera in place by tightening the four or more screws
(C) through the washers. Remember to use the base
gasket.
6. Carry out the settings and adjustments for the camera.
7. Ensure all cable entry points (rear or side) are sealed
with silicone sealent to prevent moisture ingress.
Failure to observe this may result in condensation
deposits that will reduce the IR response of the camera.
About this Manual
Before installing and using the camera, please read this manual
carefully. Be sure to keep it safe for later reference.
TROUBLESHOOTING
SPECIFICATION
Before sending the camera out for repair, check the items
below. If the problem persists after checking these items,
contact your service center.
If no image appears
Is the coaxial cable attached securely?
Are the power and voltage normal?
Has the iris of the lens inside the camera been
adjusted correctly (incorrect lens level) ?
Is there adequate illumination?
If the image is unclear
Is the lens in focus?
Is the lens dirty?
Dirt or fingerprints on the lens can adversely affect the
images. Gently wipe any dirt or fingerprints off the lens
with a soft cloth or lens cleaning paper and cleaning
fluid (commercially available).
Is the monitor adjusted correctly?
WARNING:
TO PREVENT THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE THE
INSIDE OF THIS APPLIANCE TO RAIN OR
MOISTURE. SEAL CABLE ENTRY POINTS TO
PREVENT MOISTURE FROM INTO THE
CAMERA.
CAUTION :
Check for polarity when using a DC 12V.
CONNECTOR AND CAMERA SETTING
INSTALLATION
PRECAUTIONS
DC12V AC24V
B
A
C
D
E F
D410-TP12H33V12 D410-
MODEL
General Spec
PAL
CCD Type
1/3" 470k Pixels
Color
Total number of pixels 795(H) X 596(V)
Min illumination
Video Output
Resolution
S/N Ratio
Shutter speed x128 : 1/50~1/120,000sec
Sync System
White Balance
OSD
Built-in
DAY / NIGHT
AUTO / EXTERN / B/W / COLOR
DNR LOW, MIDDLE, HIGH, OFF
Power Input
Video Output
Voltage
Power Consumption
Lens
Dimension
Weight
Case Color
Operation temp
In storage temp
Operation humidity
-10
Ԩ׽
+55
Ԩ
-20
Ԩ׽
+70
Ԩ
Under 90
(Non-condensing)
890g
Ivory
Max [DC12V : 3.0 W]
Mechanical Spec
3.3~12.0 mm / DC LENS
140(ø) X 105(H)mm
Wire
BNC Cable
Electric Spec
DC 12V ( 10.8V ~ 13.2V
)
50dB (AGC off, weight ON)
Internal / External
ATW/AWC/MANUAL (1800 ˚K ~ 10,500 ˚K)
Connectors
0.3 Lux/F1.2(50 IRE, AGC HIGH, DNR HIGH)
1.0Vp-p/75 ohm Composite
520 TV Lines(Min)
DC10-20V/ AC 20-28V 50Hz
Max ?W
Do not open or modify
Do not open the cabinet except during maintenance and
installation, as it may endanger you safety and cause damage.
Do not put objects inside the unit
Make sure that no metal objects or flammable substances get
inside the camera. It could cause fire, short-circuits or
damage.
Be careful when handling the unit
To prevent damage, do not drop the camera or subject
it to strong shock or vibration.
Install away from electric or magnetic fields
Protect from humidity and dust
Protect from high temperature
Be careful when installing close to the ceiling , in a kitchen or
boiler room, as the temperature may raise to high levels.
Always use the camera within its operating temperature range.
Cleaning
Dirt can be removed from the cabinet only by wiping it
with a soft cloth moistened with a soft detergent solution.
Mounting Surface
The mounting surface material must be strong enough to
secure the camera.
Ingress Protection
Ensure all cable entry points are sealed with silicone sealent
to prevent moisture ingress
1. Use the supplied L-wrench to remove the four fixing
screws (B) of dome cover (A).
2. Align the camera unit with the surface of the ceiling,
make marks on the ceiling in the places where the
screw holes are to be drilled, and then drill the four
holes.
3. Cut a hole (diameter2.9in.73mm) in the ceiling for
routing the cables.
4. Pass the power cable (E) and video cable (F) from the
camera unit through the cable hole in the ceiling.
5. Align the four screw holes in the camera unit (D) with
the screw holes in the ceiling, and then secure the
camera in place by tightening the four or more screws
(C) through the washers. Remember to use the base
gasket.
6. Carry out the settings and adjustments for the camera.
7. Ensure all cable entry points (rear or side) are sealed
with silicone sealent to prevent moisture ingress.
Failure to observe this may result in condensation
deposits that will reduce the IR response of the camera.
LENS ADJUSTMENTS
CAMERA SETTINGS
OSD SWITCH FUNCTION
CONNECTIONS AND CAMERA SETTINGS
1. Adjust the pan(360˚) and tilt(90˚) position.
2. Setting the zoom position by using Zoom Lever Screw.
3. Setting the focus by using Focus Lever Screw.
SETUP FUNTION SUMMARY
when using BUILT-IN lens, selecting
MANUAL will allow the aperture to be fixed
MANUAL: 1/60(50) ~
1/120,000sec, x2~ x128
WHITE BAL.
ATW, MANUAL, AWC
ATW: 1,800 ~10,500
˚
K
BACKLIGHT
OFF, LOW, MIDDLE, HIGH
Backlight compensation
AGC
NORMAL, HIGH,OFF
the Brightness can be adjusted(1 ~ 70)
MIDDLE
, HIGH, OFF, LOW
when AGC is turned off,
DNR does not operate.
when AGC is turned off,
SENS-UP does not operate
LENS
DC(=25), MANUAL
SHUTTER
ESC, MANUAL, FLK, OFF
SENS-UP
AUTO(=X6)
, OFF
OSD
DNR
CONNECTIONS AND CAMERA SETTINGS
1. Adjust the pan(360˚) and tilt(90˚) position.
2. Setting the zoom position by using Zoom Lever Screw.
3. Setting the focus by using Focus Lever Screw.
SETUP FUNTION SUMMARY
when using BUILT-IN lens, selecting
MANUAL will allow the aperture to be fixed
MANUAL: 1/60(50) ~
1/120,000sec, x2~ x128
WHITE BAL.
ATW, MANUAL, AWC
ATW: 1,800 ~10,500
˚
K
BACKLIGHT
OFF, LOW, MIDDLE, HIGH
Backlight compensation
AGC
NORMAL, HIGH,OFF
the Brightness can be adjusted(1 ~ 70)
MIDDLE
, HIGH, OFF, LOW
when AGC is turned off,
DNR does not operate.
when AGC is turned off,
SENS-UP does not operate.
SPECIAL Refer to the section below
EXIT Save the settings then exit
SPECIAL FUNTION SUMMARY
uppercase or lowercase,
OFF
maximum length for the name
/numeral 0~9/-, null display is limited 15letters.
AUTO :
daytime
colour mode ,
night-time
B/W mode
B/W : Always in B/W mode
COLOUR: Always colour mode
EXTERN : CDS EXTERNAL SIGNAL
INPUT
LL mode: you can adjust
desired phase from 0
˚
~ 359
˚
,
auto detection
MOTION ON mode: AREA(4 programmable
DETECTION zone /SIZE), the word
MOTION DETECTED" appears on the
screen when movement is detected
ON mode:AREA(4x programmable
zones) /SIZE/TONE
MIRROR
OFF
, ON
set a horizontal image inversion.
the available range
of level is 0 ~ 31.
Reset all settings to factory
defaults
save the SPECIAL MENU and then
return to the SETUP MENU
RESET
RETURN
LENS
DC(=25), MANUAL
SHUTTER
ESC, MANUAL, FLK, OFF
SENS-UP
AUTO(=X6)
, OFF
CAMERA ID
OFF
, ON
PRIVACY
OFF
, ON
SHARPNESS
OFF,
ON(=8)
OSD
DNR
DAY NIGHT
AUTO
, B/W, EXTERN, COLOR
SYNC
INT
, LL (n/a for 12VDC model)
CONNECTIONS AND CAMERA SETTINGS
1. Adjust the pan(360˚) and tilt(90˚) position.
2. Setting the zoom position by using Zoom Lever Screw.
3. Setting the focus by using Focus Lever Screw.
SETUP FUNTION SUMMARY
when using BUILT-IN lens, selecting
MANUAL will allow the aperture to be fixed
MANUAL: 1/60(50) ~
1/120,000sec, x2~ x128
WHITE BAL.
ATW, MANUAL, AWC
ATW: 1,800 ~10,500
˚
K
BACKLIGHT
OFF, LOW, MIDDLE, HIGH
Backlight compensation
AGC
NORMAL, HIGH,OFF
the Brightness can be adjusted(1 ~ 70)
MIDDLE
, HIGH, OFF, LOW
when AGC is turned off,
DNR does not operate.
when AGC is turned off,
SENS-UP does not operate.
SPECIAL Refer to the section below
EXIT Save the settings then exit
SPECIAL FUNTION SUMMARY
uppercase or lowercase,
OFF
maximum length for the name
/numeral 0~9/-, null display is limited 15letters.
AUTO :
daytime
colour mode ,
night-time
B/W mode
B/W : Always in B/W mode
COLOUR: Always colour mode
EXTERN : CDS EXTERNAL SIGNAL
INPUT
LL mode: you can adjust
desired phase from 0
˚
~ 359
˚
,
auto detection
MOTION ON mode: AREA(4 programmable
DETECTION zone /SIZE), the word
MOTION DETECTED" appears on the
screen when movement is detected
ON mode:AREA(4x programmable
zones) /SIZE/TONE
MIRROR
OFF
, ON
set a horizontal image inversion.
the available range
of level is 0 ~ 31.
Reset all settings to factory
defaults
save the SPECIAL MENU and then
return to the SETUP MENU
RESET
RETURN
LENS
DC(=25), MANUAL
SHUTTER
ESC, MANUAL, FLK, OFF
SENS-UP
AUTO(=X6)
, OFF
CAMERA ID
OFF
, ON
PRIVACY
OFF
, ON
SHARPNESS
OFF,
ON(=8)
OSD
DNR
DAY NIGHT
AUTO
, B/W, EXTERN, COLOR
SYNC
INT
, LL (n/a for 12VDC model)
  • Page 1 1
  • Page 2 2

Vision Technology D410-TP22H33V12 User manual

Category
Security camera accessories
Type
User manual

Vision Technology D410-TP22H33V12 is a vandal-proof camera with a 1/3" 470k pixel CCD sensor and a resolution of 520 TV lines. It has a minimum illumination of 0.3 Lux and a shutter speed of 1/50~1/120,000sec. The camera also features built-in day/night functionality, which allows it to automatically switch between color and black-and-white modes depending on the lighting conditions. Other features include automatic white balance, backlight compensation, and digital noise reduction. The camera is powered by a 12V DC power supply and has a power consumption of 3.0 W.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI