Paradyne 9261, 9161 Single T1 Reference guide

  • Hello! I am an AI chatbot trained to assist you with the Paradyne 9261 Reference guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
TM
1
916x/926x T1 Access Mux
Quick Reference
Document Number 9161-A2-GL10-10
December 1998
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Complete documentation for this product is available at www.paradyne.com.
Select
Service & Support
Technical Manuals
T1 Access Multiplexers.
Select the following document:
9161-A2-GH30
Model 916x/926x T1 Access Mux Technical Reference
To request a paper copy of a Paradyne document:
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623
Overview
This quick reference summarizes the configuration options accessed when you select
Configuration from the Main Menu. Not all options are available, but are filtered
depending on what other options have been selected. Refer to Chapter 5,
Setting Up
,
in the
Model 916x/926x T1 Access Mux Technical Reference
for more information.
2
98-15081-03
Status
System and Test Status
Voice Status
Cross Connect Status
Performance Statistics
Identity
Network
Sync Data Ports
Clear Statistics
System & NAM
APM
Network Channel Display
DSX-1 Channel Display
Port Assignment Display
MAIN MENU
Status
Test
Configuration
Control
Configuration Edit/Display
Network
DSX-1
Sync Data Ports
Voice Ports
OCU-DP
Copy Ports
Cross Connect
System Options
User Interface
Alarm
Management and Communication
DSX-1 to Network
Assignments
Network to Network
Assignments
Voice Port
Assignments
Sync Data Port
Assignments
OCU-DP Port
Assignments
Clear Assignments
Communication Port
External Device
(Com Port)
Telnet/FTP Sessions
Communication
Protocol
General SNMP
Management
SNMP NMS Security
SNMP Traps
MAIN MENU
Status
Test
Configuration
Control
MAIN MENU
Status
Test
Configuration
Control
Test
Network Tests
DSX-1 Tests
Sync Data Port Tests
Voice Port Tests
OCU-DP Tests
Device Tests
Abort Tests
Control
COM Port Call Setup
COM Port Call Directories
Device Name
Date & Time
Administer Logins
System Alarm Relay Cut-Off
Clear Device Fail
Reset Device
MAIN MENU
Status
Test
Configuration
Control
Load
Configuration
from:
Menu
Hierarchy
3
Network
Configuration Option Settings
Default in [Bold]
Network 1, 2
Interface Status
1
Enable, [Disable]
Line Framing Format D4, [ESF]
Line Coding Format AMI, [B8ZS]
Line Build Out (LBO) [0.0], –7.5, –15, –22.5
Bit Stuffing [62411], Part68, Disable
Network Initiated LLB [Enable], Disable
Network Initiated PLB [Enable], Disable
Transmit Timing
3
[System], Network
ANSI Performance Report
Messages
Enable, [Disable]
Management Link [Disable], FDL, DDL
IP Address
2
[000.000.000.000] – 223.255.255.255, Clear
Subnet Mask [000.000.000.000] – 255.255.255.255, Clear
Routing Information Protocol None, [Proprietary]
Network Time Slot 01–24 [lowest available time slot]
Circuit Identifier Text field
Loss of Signal (LOS) Alarm [Enable], Disable
Out of Frame (OOF) Alarm [Enable], Disable
Alarm Indication Signal (AIS) [Enable], Disable
Yellow Alarm [Enable], Disable
Excessive Error Rate (EER)
Alarm
[Enable], Disable
Excessive Error Rate Threshold [10E-4], 10E-5, 10E-6, 10E-7, 10E-8, 10E-9
1
Read-only when Network is set to 1.
2
This first byte cannot be set to 0 nor 127. However, the null address of 0.0.0.0 is
valid after performing a Clear.
3
Only shown when 9261 T1 NAM is being used.
4
DSX-1
Configuration Option Settings
Default in [Bold]
Slot
ss
916x: 01
9261 NAM: 02
9265: 02, 03, 04, 05
Port
p
916x: 1
926x: 1, 2
Interface Status Enable, [Disable]
Line Framing Format D4, [ESF]
Line Coding Format AMI, [B8ZS]
Line Equalization [0–133], 133–266, 266–399, 399–533, 533–655
Send All Ones on DSX-1 Failure [Enable], Disable
Loss of Signal (LOS) Alarm [Enable], Disable
Out of Frame (OOF) Alarm [Enable], Disable
Alarm Indication Signal (AIS) [Enable], Disable
Yellow Alarm [Enable], Disable
5
Sync Data Ports
Configuration Option Settings
Default in [Bold]
Slot
ss
9x62: 01, 02
9x65: 01, 02, 03, 04, 05
Port
p
T1 NAM: 1, 2
Sync Data APM: 1, 2, 3, 4
Port Status Enable, [Disable]
Port Type [E530], V.35, RS449, X.21
Port Base Rate [Nx64], Nx56
Transmit Clock Source [Internal], External
Invert Transmit Clock Enable, [Disable]
Invert Transmit and Received
Data
Enable, [Disable]
Send All Ones on Data Port Not
Ready
Disable, DTR, RTS, [Both]
Action on Network Yellow Alarm None, [Halt]
Network Initiated Data Channel
Loopback (DCLB)
[Disable], V.54, FT1, Both
Port (DTE) Initiated Loopbacks [Disable], DTPLB, DCLB, Both
Embedded Data Link Enable, [Disable]
EDL Management Link Enable, [Disable]
IP Address
1
[000.000.000.000] – 223.255.255.255, Clear
Subnet Mask [000.000.000.000] – 255.255.255.255, Clear
Routing Information Protocol None, [Proprietary]
Near-End Performance Statistics [Disable], Maintain, Send, Both
Far-End Performance Statistics [Disable], Maintain
Out of Frame (OOF) Alarm [Enable], Disable
Excessive Error Rate (EER)
Alarm
[Enable], Disable
Excessive Error Rate Threshold [10E-4], 10E-5, 10E-6, 10E-7, 10E-8, 10E-9
1
This first byte cannot be set to 0 nor 127. However, the null address of 0.0.0.0 is
valid after performing a Clear.
6
Voice Ports
Configuration Option Settings
Default in [Bold]
E&M Voice
Slot
ss
9x62: 02
9x65: 02, 03, 04, 05
Port
p
1, 2, 3, 4, 5, 6, 7, 8
Port Status Enable, [Disable]
Operating Mode [E&M], Transmit Only
Rx Gain (dB) –17.0, –16.5, –16.0, –15.5, –15.0, ..., [0.0],
..., +6.5, +7.0, +7.5
Tx Attenuation (dB) –17.0, –16.5, –16.0, –15.5, –15.0, ..., [0.0],
..., +6.5, +7.0, +7.5
Trunk Cond in CGA [Busy], Idle
FXO Voice
Slot
ss
9x62: 02
9x65: 02, 03, 04, 05
Port
p
1, 2, 3, 4, 5, 6, 7, 8
Port Status Enable, [Disable]
Operating Mode [FXO], FXODN, FXODN/WINK, DPT
Signaling Type [Loop-Start], Loop-Start/Fwd-Disc, Ground-Start
Terminating Impedance (ohms) [600], 900
Wink Delay (10 ms) 1 – 99 [15]
Wink Duration (10 ms) 1 – 99 [20]
Rx Gain (dB) –10.00, –9.5, –9.0, –8.5, ..., [0.0], +0.5,
+1.0, +1.5, +2.0
Tx Attenuation (dB) –10.00, –9.5, –9.0, –8.5, ..., [0.0], ..., +4.0,
+4.5, +5.0
Trunk Cond in CGA [Busy], Idle
7
Voice Ports (continued)
FXS Voice
Slot
ss
9x62: 02
9x65: 02, 03, 04, 05
Port
p
1, 2, 3, 4, 5, 6, 7, 8
Port Status Enable, [Disable]
Operating Mode [FXS], FXSDN, FXSDN/WINK, PLAR, DPO
Signaling Type [Loop-Start], Loop-Start/Fwd-Disc,
Ground-Start, Ground-Start-Immediate,
Ground-Start-Automatic, d3, d4
Terminating Impedance (ohms) [600], 900
Wink Delay (10 ms) 1 – 99 [15]
Wink Duration (10 ms) 1 – 99 [20]
Rx Gain (dB) –10.00, –9.5, –9.0, –8.5, ..., [0.0], +0.5,
+1.0, +1.5, +2.0
Tx Attenuation (dB) –10.00, –9.5, –9.0, –8.5, ..., [0.0], ..., +4.0,
+4.5, +5.0
Ring-Back Tone Enable, [Disable]
Trunk Cond in CGA [Busy], Idle
8
OCU-DP Ports
Configuration Option Settings
Default in [Bold]
Slot
ss
9x62: 02
9x65: 02, 03, 04, 05
Port
p
2-port: 1, 2
6-port: 1, 2, 3, 4, 5, 6
Port Status Enable, [Disable]
Port Rate [56K], 64KCC, Switched_56
Loopback Detection [Enable], Disable
Loss of Signal Alarm [Enable], Disable
Abnormal Station Code Alarm [Enable], Disable
64KCC Loop OOF Alarm [Enable], Disable
DDS Network Failure Alarm [Enable], Disable
Loss of Loop Timing Alarm [Enable], Disable
9
Cross Connect
See the
Technical Reference
for information on cross connections.
Copy Ports
Configuration Option Settings
Default in [Bold]
From: Slot
ss
9x62: 01, 02
9x65: 01, 02, 03, 04, 05
From: Port
p
T1 NAM: 1, 2
Sync Data APM: 1, 2, 3, 4
Voice APM: 1, 2, 3, 4, 5, 6, 7, 8
OCU-DP (2-port): 1, 2
OCU-DP (6-port): 1, 2, 3, 4, 5, 6
Type T1 NAM, Sync Data, FXS Voice, FXO Voice,
E&M Voice, OCU-DP
To: Slot
ss
9x62: All, 01, 02
9x65: All, 01, 02, 03, 04, 05 [lowest numbered
slot containing the same port type]
To: Port
p
T1 NAM: 1, 2
Sync Data APM: 1, 2, 3, 4
Voice APM: 1, 2, 3, 4, 5, 6, 7, 8
OCU-DP (2-port): 1, 2
OCU-DP (6-port): 1, 2, 3, 4, 5, 6
Perform Copy n/a
Perform Copy Then Increment n/a
10
System Options
Configuration Option Settings
Default in [Bold]
Generate Yellow Alarm Signals [Enable], Disable
Test Timeout [Enable], Disable
Test Duration (min) 1 – 120 [10]
Primary Clock Source [Net1], Net2, DSX
ss
-
p
, Internal, External, Sync
Data
Port (for Primary Clock Source) S
ss
P
p
[the first available port]
Secondary Clock Source Net1, Net2, DSX
ss
-
p
, [Internal], External, Sync
Data
Port (for Secondary Clock Source) S
ss
P
p
[the first available port]
External Clock Rate (KHz) 8, [1544], 2048
Primary Clock Failure Alarm [Enable], Disable
Secondary Clock Failure Alarm [Enable], Disable
11
User Interface
Configuration Option Settings
Default in
[Bold]
Communication Port
Physical characteristics of the Port (Port 1 or 2)
Port Use [Terminal], Net Link, Alarm
Port Type [Asynchronous], Synchronous
RIP
1
[None], Proprietary
Port Type – Synchronous
Clock Source [Internal], External
Data Rate (Kbps)
2
9.6, 14.4, [19.2], 28.8, 38.4, 57.6, 115.2
Port Type – Asynchronous
Data Rate (Kbps) 9.6, 14.4, [19.2], 28.8, 38.4, 57.6, 115.2
Character Length
3
7, [8]
Parity
3
[None], Even, Odd
Stop Bits
3
[1], 1.5, 2
Ignore Control Leads [Disable], DTR
Login Required
4
Enable, [Disable]
Port Access Level
4
[Level-1], Level-2, Level-3
Inactivity Timeout
4
Enable, [Disable]
Disconnect Time (Minutes)
4,5
1 – 60 [5]
1
Only shown when Port Use is set to Net Link.
2
Only shown when Clock Source is set to Internal.
3
Only shown when Port Type is set to Asynchronous.
4
Only shown when Port Use is set to Terminal.
5
Only shown when Inactivity Timeout is set to Enable.
12
User Interface (continued)
Configuration Option Settings
Default in
[Bold]
External Device (COM Port)
External Device Commands [Disable], AT, Other
Dial-In Access
6
Enable, [Disable]
Connect Prefix
7
ASCII text entry, Clear
Connect Indication String
7
ASCII text entry, Clear
Escape Sequence
7
ASCII text entry, Clear
Escape Sequence Delay (Sec)
7
[None], 0.2, 0.4, 0.6, 0.8, 1.0
Disconnect String
7
ASCII text entry, Clear
Telnet/FTP Sessions
Telnet Session Enable, [Disable]
Telnet Login Required Enable, [Disable]
Session Access Level [Level-1], Level-2, Level-3
Inactivity Timeout Enable, [Disable]
Disconnect Time (Minutes) 1 – 60 [5]
FTP Session Enable, [Disable]
FTP Login Required Enable, [Disable]
6
Only shown when External Device Commands is set to Other or AT.
7
Only shown when External Device Commands is set to Other.
Alarm
Configuration Option Settings
Default in
[Bold]
ASCII Alarm Messages Com Port, [Disable]
Alarm & Trap Dial Out Enable, [Disable]
Trap Disconnect [Enable], Disable
Call Retry Enable, [Disable]
Dial-Out Delay Time (Min) 1 – 10 [5]
Alternate Dial-Out Directory [None], 1 – 5
System Alarm Relay Enable, [Disable]
13
Management and Communications
Configuration Option Settings
Default in
[Bold]
Communication Protocol
Node IP Address
1
[000.000.000.000] – 223.255.255.255, Clear
Node Subnet Mask [000.000.000.000] – 255.255.255.255, Clear
Default Network Destination [None], COM, FDL1, FDL2, DDL, EDL
ss-p
Communication Port IP Address
1
[000.000.000.000] – 223.255.255.255, Clear
Communication Port Subnet Mask [000.000.000.000] – 255.255.255.255, Clear
Communication Port Link Protocol [PPP], SLIP
Alternate Communication Port IP
Address
1
[000.000.000.000] – 223.255.255.255, Clear
Alternate Communication Port
Subnet Mask
[000.000.000.000] – 255.255.255.255, Clear
General SNMP Management
SNMP Management Enable, [Disable]
Community Name 1 ASCII text entry [Public], Clear
Name 1 Access [Read], Read/Write
Community Name 2 ASCII text entry, [Clear]
Name 2 Access [Read], Read/Write
SNMP NMS Security
NMS IP Validation Enable, [Disable]
Number of Managers 1 – 10 [1]
NMS
n
IP Address [000.000.000.000] – 223.255.255.255, Clear
Access Level [Read], Read/Write
1
The first byte cannot be set to 0 nor 127. However, the null address of
0.0.0.0 is valid after performing a Clear.
14
Management and Communications (continued)
SNMP Traps
SNMP Traps Enable, [Disable]
Number of Trap Managers 1 – 6 [1]
NMS
n
IP Address
1
[000.000.000.000] – 223.255.255.255, Clear
Destination [Default], COM, FDL1, FDL2, DDL, EDL
ss-p
General Traps Disable, Warm, AuthFail, [Both]
Enterprise Specific Traps Enable, [Disable]
Link Traps Disable, Up, Down, [Both]
Link Traps Interfaces
2
Network, DSX-1, T1s, Ports, [All]
1
The first byte cannot be set to 0 nor 127. However, the null address of 0.0.0.0 is
valid after performing a Clear.
2
DSX-1 and T1s only shown when DSX-1 interface is enabled.
15
Warranty, Sales, and Service Information
Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:
H Via the Internet: Visit the Paradyne World Wide Web site at
http://www.paradyne.com
H Via Telephone: Call our automated call system to receive current information via
fax or to speak with a company representative.
Within the U.S.A., call 1-800-870-2221
Outside the U.S.A., call 1-727-530-2340
Document Feedback
We welcome your comments and suggestions about this document. Please mail them
to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL
33773, or send e-mail to [email protected]. Include the number and title of
this document in your correspondence. Please include your name and phone number if
you are willing to provide additional clarification.
Trademarks
All products and services mentioned herein are the trademarks, service marks,
registered trademarks or registered service marks of their respective owners.
Copyright E 1998 Paradyne Corporation
/