McAfee NS7200, NS7100, NS7300 Quick start guide

  • Hello! I am an AI chatbot trained to assist you with the McAfee NS7200 Quick start guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
This quick start guide explains how to quickly set up and activate your McAfee
®
Network Security Platform
NS7100, NS7200, and NS7300 Sensors in in-line mode. These models have a throughput of 1.5 Gbps, 3
Gpbs, and 5 Gbps respectively.
All product documentation referenced in this quick start guide is found on the McAfee ServicePortal.
The NS7100/NS7200/NS7300 Sensor model
Figure 1 Sensor front panel
1
Console port (1)
2
RJ-11 port (1) for fail-open control of two built-in SFP+ ports in slot G0. The RJ-11 port supports 1
Gbps (SFP) copper or fiber and 10 Gbps (SFP+) (SR and LR).
3
SFP+ 1/10 Gigabit Ethernet ports (2)
The RJ-11 port controls only the SFP+ 1/10 port pair in passive fail-open mode.
4
Two slots for I/O modules (Any combination of the interface modules can be used.)
SFP/SFP+ 1/10 GigE Monitoring ports (8)
RJ-45 10/100/1000 Mbps with internal fail-open Ethernet Monitoring ports (6)
10/1 GigE SM 8.5 micron with internal fail-open Monitoring ports (4)
10/1 GigE MM 50 micron with internal fail-open Monitoring ports (4)
10/1 GigE MM 62.5 micron with internal fail-open Monitoring ports (4)
5
RJ-45 10/100/1000 Mbps Ethernet Monitoring ports (8)
NS7x00 Quick Start Guide
Revision C
McAfee Network Security Platform
1
The supported transceiver modules are SFP+ (M2M and SM), SFP Fiber (MM and SM) and SFP Copper.
Figure 2 Sensor rear panel
1
Auxiliary port (1)
2
USB ports (2)
3
Power supply inlet (2)
The NS7x00 Sensors are shipped with one power supply unit. Second power supply
(optional) is supported to enable redundancy.
4
RJ-45 10/100/1000 Response port (R1) (1)
5
RJ-45 10/100/1000 Management port (Mgmt) (1)
1 Verify the contents in the box
The following accessories are shipped in the NS7x00 Sensor crate:
Sensor
Power cords (McAfee provides standard and international power cables.)
Set of rack mounting rails
Printed Quick Start Guide
2 Verify the hardware and software requirements
Make sure to meet the following hardware requirements. For more information, see the McAfee
Network Security Platform Installation Guide.
The following are the system requirements for a Manager server.
2
Minimum required Recommended
Operating
system
Any of the following Microsoft operating systems:
Windows Server 2008 R2 Standard or Enterprise
Edition, SP1 (Full Installation), English operating
system
Windows Server 2008 R2 Standard or Enterprise
Edition, SP1 (Full Installation), Japanese operating
system
Windows Server 2012 Standard Edition (Server with a
GUI) English operating system
Windows Server 2012 Standard Edition (Server with a
GUI) Japanese operating system
Windows Server 2012 R2 Standard Edition (Server with
a GUI) English operating system
Windows Server 2012 R2 Standard Edition (Server with
a GUI) Japanese operating system
Windows Server 2012 R2 Datacenter Edition (Server
with a GUI) English operating system
Windows Server 2012 R2 Datacenter Edition (Server
with a GUI) Japanese operating system
Only X64 architecture is supported.
Same as the minimum
required.
Memory 8 GB 8 GB or more
CPU Server model processor such as Intel Xeon Same
Disk space 100 GB 300 GB or more
Network 100 Mbps card 1000 Mbps card
Monitor 32-bit color, 1440 x 900 display setting 1440 x 900 (or higher)
The following are the system requirements for client systems connecting to the Manager application.
Minimum Recommended
Operating
system
Windows 7 English or Japanese
Windows 8 English or Japanese
Windows 8.1 English or Japanese
The display language of the Manager client
must be same as that of the Manager server
operating system.
RAM 2 GB 4 GB
3
Minimum Recommended
CPU 1.5 GHz processor 1.5 GHz or faster
Browser
Microsoft Internet Explorer 9, 10, or 11
Mozilla Firefox
Google Chrome (App mode in Windows 8 is not
supported.)
If you are using Google Chrome, add the
Manager certificate to the trusted certificate
list.
Internet Explorer 11
Mozilla Firefox 20.0 or
later
Google Chrome 24.0 or
later
Install the following software:
Sensor image
Manager image
Signature set
3 Install the slide rails and rack-mount the Sensor
McAfee recommends rack-mounting your Sensor. For maintenance purposes, you must have access
to the front and rear of the Sensor.
Before you mount the Sensor on the rack, make sure that the power is off. Remove the
power cable and all network interface cables from the Sensor.
Due to the weight of the appliance, McAfee recommends that two people place the chassis
into the rail cabinet.
a
Disassemble the inner slide rail members from the cabinet sections.
a
Pull the inner member out until it comes to a lock position.
b
Depress the QD latch to fully disconnect the inner members.
4
b
Mount the inner members to the chassis unit.
a
Place each inner member on both sides of the chassis unit. Position the bottom mounting
holes of the inner member with matching mounting holes on chassis unit.
b
Use screws to secure inner members in place. Apply to both sides of chassis unit.
c
Mount the slide cabinet sections to the rack.
a
Install the front end of each slide cabinet section to the rack using the slide tool-less
features. The tool-less latch rotates when the bracket is pressed up against the rack rails.
b
Align, adjust, and attach the rear brackets to the rack rail.
5
d
Mount the chassis unit into the mounted cabinet sections.
a
Guide the chassis unit into the pre-installed cabinet sections. Allow the pre-installed inner
members to slide into the outer members until they lock in place.
b
Depress the QD latch on both sides and continue to push the chassis unit in until fully
closed.
e
Secure the chassis unit through the rack rails.
a
With the chassis unit in a fully closed position, secure using two truss head screws.
b
Drive the screws through the inner member flange and through the rack rails. The screws
thread directly to the cabinet slide members. Tighten the screws.
4 Install the interface modules
You can purchase the following interface modules and insert them into the relevant slots on your
NS7x00 Sensor.
8-port SFP/SFP+ 1/10 Gigabit interface module
4-port RJ-45 10 Gbps/1 Gbps/100 Mbps with internal fail-open interface module
6-port RJ-45 10/100/1000 Mbps with internal fail-open interface module
4-port 10/1 GigE SM 8.5 micron with internal fail-open interface module
6
4-port 10/1 GigE MM 50 micron with internal fail-open interface module
4-port 10/1 GigE MM 62.5 micron with internal fail-open interface module
a
Remove the module from its protective packaging.
b
Hold the module using your thumb and forefinger and insert it into the modular bay.
c
Drive in the screws fixed on the sides of the module to attach it to the Sensor.
5 Connect the Management and Console ports
a
On the rear panel of the NS7x00 Sensors, plug a Category 5e Ethernet cable in the Management
port (labeled Mgmt).
b
Plug the other end of the cable into the network device connected to your Manager server.
7
c
On the front panel of the NS7x00 Sensors, plug the DB9 Console cables into the Console port
(labeled Console).
d
Connect the other end of the Console port cable directly to a COM port of the PC or terminal
server you are using to configure the Sensor (for example, a PC running correctly configured
Windows Hyperterminal software). You must directly connect to the console for initial
configuration, you cannot configure the Sensor remotely.
Terminal servers are provided for console access.
The required settings for Hyperterminal are:
Baud rate: 115200 Stop Bits: 1
Number of Bits: 8 Control Flow: None
Parity: None
e
Plug one end of the power cable into the power inlet and plug the other end into a power source.
The Sensor ships with standard US power and international cables.
The NS-series Sensor does not have a power switch. You can directly plug the power
cable into a power source.
8
6 Connect the monitoring ports
This procedure describes how to connect cables to a Sensor that runs in in-line mode.
a
Plug the cable appropriate for use with your transceiver module into one of the monitoring ports
labeled x (for example, 1).
b
Plug the cable appropriate for use with your transceiver module into one of the monitoring ports
labeled y (for example, 2).
c
Connect the other end of each cable to the network devices that you want to monitor. For
example, if you plan to monitor traffic between a switch and a router, connect the cable
connected to 1 to the router and the one connected to 2 to the switch.
7 Install the Manager software
For detailed instructions, see the McAfee Network Security Platform Installation Guide.
You must have administrator rights on the target Windows Server to install the Manager
software.
A MySQL database is included with the Manager and is installed (embedded) automatically
on your target Windows Server during this process.
The following steps briefly explain the Manager installation:
a
Prepare the system according to the requirements outlined in McAfee Network Security Platform
Installation Guide and the McAfee Network Security Platform Release Notes.
b
Close all open applications.
c
Go to the McAfee Update Server (https://menshen1.intruvert.com/) and log on, using the grant
number and password.
d
Go to the Manager Software Updates folder and select the latest Manager software version available.
e
Download the .zip file to the target Windows Server and extract the setup file.
f
Double-click Manager _<version>_setup.exe and follow the on-screen prompts.
8 Start the Manager
Click Start | Programs | McAfee | Network Security Manager | Network Security Manager.
9
9 Add the Sensor to the Manager
The Manager displays the Logon page.
a
Log on to the Manager using the default user name (admin) and password (admin123).
b
Click Devices.
c
To add a Sensor in the Manager, click Global | Add and Remove Devices, then click New.
You do not require a license file to enable IPS on NS-series Sensors.
The Add New Device page is displayed. We recommend using the Add Device wizard to add a
device.
d
Enter the following mandatory information in the appropriate fields.
1)
Device Name — The Sensor name must begin with a letter. The maximum length of the name
is 25 characters.
2)
Device Type — Specifies the type of device to be added. Select IPS Sensor.
10
3)
Shared Secret — The shared secret must be a minimum of 8 characters and maximum of 25
characters in length. The key cannot start with an exclamation mark nor can have any
spaces. The parameters that you can use to define the key are:
26 alphabets: Uppercase and
lowercase (A, B, C,...Z and a,b,c,...z)
32 symbols: ~ ` ! @ # $ % ^ & * ( )
_ + = [ ] { } \ | ; : " ' , . <? /
10 digits: 0 1 2 3 4 5 6 7 8 9
The Sensor name and shared secret key that you enter in the Manager must be
identical to the shared secret that you will later enter during physical installation or
initialization of the Sensor (using CLI) in Step 10 - Configure Sensor information. If
not, the Sensor will not be able to register itself with the Manager.
4)
Updating Mode — Select Online or Offline.
Selecting Offline enables Offline Sensor update. Online is the default mode.
e
Click Save. The added Sensor is displayed on the Add and Remove Devices page.
10 Configure Sensor information
Configure the Sensor with the network information, a name, and the shared secret key that the
Sensor uses to establish secure communication with the Manager. Use the name and key values you
set in Step 9 - Add the Sensor to the Manager.
The first time you configure a Sensor, you must have physical access to the Sensor.
At any time during configuration, you can type a question mark (?) to get help on the Sensor CLI
commands. For a list of all commands, type commands.
a
Log on to the Sensor using the terminal connected to the Console port.
b
At the prompt, log on using the default Sensor user name (admin) and password (admin123).
11
c
Optional, but recommended. Change the Sensor password. At the prompt, type: passwd.The
Sensor prompts you to enter the new password and prompts you for the old password.
A password must contain between 8–25 characters, is case sensitive, and can consist of
any alphanumeric character or symbol.
d
Set the name of the Sensor:
You can enter the setup command at the prompt. This automatically prompts you to
provide the information shown in items d through g and item j. Alternatively, you can
use the set command. If you use the set command, manually enter the complete
command syntax as shown in items d through g and item j.
At the prompt, type: set sensor name <word>.
Example: set sensor name HR_sensor1
The Sensor name is a case-sensitive character string up to 25 characters. The string
can include hyphens, underscores, and periods, and must begin with a letter.
e
If the Sensor is not on the same network as the Manager, set the address of the default
Gateway. At the prompt, type: set sensor gateway <A.B.C.D>
Example: set sensor gateway 192.168.3.68
f
Set the IP address of the Manager server. At the prompt, type: set manager ip <A.B.C.D>.
Example: set manager ip 192.168.2.8
g
Set the IP address and subnet mask of the Sensor. At the prompt, type: set sensor ip
<A.B.C.D> <E.F.G.H>.
Example: set sensor ip 192.168.2.12 255.255.255.0
Specify an IP address using four octets separated by periods: X.X.X.X, where X is a
number between 0 and 255, followed by a subnet mask in the same format.
h
If prompted, reboot the Sensor. Type: reboot
The Sensor can take up to five minutes to complete its reboot.
i
Ping the Manager from the Sensor to determine if your configuration settings to this point have
successfully established the Sensor on the network. At the prompt, type:
ping <manager IP address>.
If the ping is successful, continue with the following steps. If not, type show to verify your
configuration settings and check that the information is correct.
j
Set the shared secret key value for the Sensor. At the prompt, type:
12
set sensor sharedsecretkey
The Sensor then prompts you to enter and then confirm the shared secret key value.
This value is used to establish a trust relationship between the Sensor and the
Manager. The secret key value can be between 8 and 25 characters of any ASCII text.
The shared key value is case-sensitive. Make sure that the value matches the shared
secret key value you provided in the Manager interface in Step 9 - Add the Sensor to
the Manager.
k
To verify the configuration information, type show. Check that all information is correct.
l
To exit the session, type exit.
11 Verify successful installation
a
In the Sensor CLI, type: status. The status report is displayed.
The Sensor parameter System Initialized must be yes, and for Manager communication
Trust Established must be yes.
b
From the Manager Dashboard, view the Manager status in the System Health monitor.
13
The Manager status displays as Up and Sensor status is Active.
c
From the Manager, click Devices | <Device_Name> | Setup | Physical Ports to open the Physical Ports
page.
<Device_Name> indicates the name of the Sensor you added.
d
A policy named Default Inline IPS is active upon Sensor addition. To view this policy, select
Intrusion Prevention | Policy | IPS Policies. Select Default Inline IPS from the list and click View / Edit.
The Default Inline IPS policy contains attacks already configured with a "blocking"
Sensor response action. If any attack in the policy is triggered, the Sensor
automatically blocks the attack. To tune this or any other McAfee-provided policies, you
can clone the policy and then customize it as described in the McAfee Network Security
Platform IPS Administration Guide.
e
Click Devices | <Device_Name> | Setup | Physical Ports.
f
Select the port on the Sensor that you cabled to view port settings. Make sure that your port
settings match the cabling, for example, if port 1 is cabled for the in-line mode, then the Operating
Mode in the port setting must be in-line mode.
For more information on port settings, see Configuring the monitoring and response
ports of a Sensor, McAfee Network Security Platform IPS Administration Guide.
14
12 You're up and running!
Your Sensor is actively monitoring connected segments and communicating with the Manager for
administration and management operations.
a
For detailed usage instructions, see the McAfee Network Security Platform IPS Administration
Guide, or click the Detailed Help buttons in the upper-right corner of each window in the Manager.
b
Start the Analysis | Threat Analyzer to view alert statistics as attacks are detected. A summary of
alerts is displayed in the Unacknowledged Alert Summary area of the Manager Dashboard page.
c
Having problems? See the McAfee Network Security Platform Troubleshooting Guide for
troubleshooting information.
d
Most deployment problems stem from configuration mismatches between the Sensor and the
network devices to which it is connected. Check the duplex and auto-negotiation settings on
both devices to ensure that they are synchronized.
To contact technical support, go to https://support.mcafee.com.
15
© 2017 Intel Corporation
Intel and the Intel logo are trademarks/registered trademarks of Intel Corporation. McAfee and the McAfee logo are trademarks/
registered trademarks of McAfee, Inc. Other names and brands may be claimed as the property of others.
16 700-4423C00
/