Cross Technologies 2009-8487P Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Cross Technologies 2009-8487P Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the frequency range of the Cross Technologies 2009-8487P?
    What is the impedance of the RF and IF ports of the device?
    What is the maximum input level for the 2009-8487P?
    What is the gain of the device at band center?
    What is the frequency accuracy of the 2009-8487P?
    What power supply options are available for the 2009-8487P?
    What are the dimensions of the 2009-8487P?
Instruction Manual
Model 2009-8487P
Up/DownConverter
November 2013, Rev. A
CROSS TECHNOLOGIES, INC.
DC ALARM
2009 TEST CONVERTER
DC POWER
IF
RF
J1 J3 J2
C
ROSS TECHNOLOGIES, INC.
+DC IN
+15V, 300 ma
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment
model number, equipment serial number, and a description of the part.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
INSTRUCTION MANUAL
MODEL 2009-8487P Up/DownConverter
TABLE OF CONTENTS PAGE
Warranty 2
1.0 General 3
1.1 Equipment Description 3
1.2 Technical Characteristics 4
2.0 Installation 5
2.1 Mechanical 5
2.2 Front Panel Indicators 5
2.3 Rear Panel Inputs and Outputs 6
2.4 Accessing the PC Card 6
2.5 Installation/Operation 6
3.0 Environmental Use Information 7
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.
All Cross Technologies, Inc. products are warranted against defective materials and
workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s
obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option,
replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be
liable for any special, indirect, or consequential damages. This warranty does not cover parts
or equipment which have been subject to misuse, negligence, or accident by the customer
during use. All shipping costs for warranty repairs will be prepaid by the customer. There
are not other warranties, express or implied, except as stated herein.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
2009-8487P Manual, Rev. A Page 2 11/11/13
Model 2009-8487P Up/DownConverter
1.0 General
1.1 Equipment Description
The 2009-8487P Up/DownConverter, for loop-back applications, converts a 8.487 GHz signal to or from 67
MHz with a low side local oscillator (LO) (non-inverted spectrum). Featuring low phase noise and high
stability, this unit is used to down convert “clean” (having only this frequency) 8.487 GHz signal to 67 MHz or
up convert 67 MHz to 8.487 GHz for test purposes. A synthesized local oscillator (LO) of 8.420 GHz converts
the 8.487 GHz signal to 67 MHz when used as a Downconverter and the 67 MHz signal to 8.487 GHz when
used as a Upconverter with a nominal gain of -15dB. Connectors are SMA (female) for the 67 MHz IF and the
RF ports. Front panel LEDs light when DC power is applied (green) and when a PLL alarm occurs (red). The
unit is powered by a 120 ±10% VAC wall mount power supply (suffix P) and other power supply options are
available (option P4 or option -C). The 2009 can be mounted on an 1.75” X 19” rack mount panel (option R).
CROSS TECHNOLOGIES, INC.
DC ALARM
2009 TEST CONVERTER
DC POWER
IF
RF
J1 J3 J2
C
ROSS TECHNOLOGIES, INC.
+DC IN
+15V, 300 ma
FIGURE 1.1 Front and Rear Panels
67
MHz
8.487
GHz
atten
8.420 GHz
PLL
2009-8487P Block Diagram
LP
FILTER
FIGURE 1.2 Block Diagram
2009-8487P Manual, Rev. A Page 3 11/11/13
1.2 Technical Characteristics
TABLE 1.1 Model 2009-8487P Equipment Specifications*
EQUIPMENT SPECIFICATIONS*
RF Characteristics
Impedance / Return Loss 50Ω / 12 db
Frequency 8487 MHz ± 20 MHz
Level, In, Downconverter -30 to -5 dBm
Level, Out, Upconverter -30 to -20 dBm
Input 1 dB compression +5 dBm
IF Characteristics
Impedance / Return Loss 50Ω / 12 db
Frequency 67 MHz ± 20 MHz
Level, In, Upconverter -15 to -5 dBm
Level, Out, Downconverter -45 to -20 dBm
Channel Characteristics
Gain at band center -15 dB ±2 dB
Spurious Response <-40 dBC, ± 20 MHz of the center frequency
Spectrum Sense Non-inverting
Frequency Response ± 0.5 dB, ± 20 MHz of the center frequency
Synthesizer Characteristics
Frequency Accuracy ± 2.5 ppm maximum
-110-95-80-75-70
1MHz100kHz10kHz1kHz10Hz
dBC/Hz
Phase Noise
@
Fre
q
Indicators
DC Power Green LED
Alarm Red LED
Other
RF Connector SMA (female), 50Ω
IF Connector SMA (female), 50Ω
Size, Bench Top 4.7” wide X 1.75” high X 6.5” deep
Size, Rack Mount (-R) 19 inch standard chassis 1.75” high X 7.0” deep (optional)
Power 120 ±10% VAC Wall Power Supply providing +15 to +18 VDC
Options
-C No Power Supply. Use with Cross 2000-01 Power Supply
-P4 100-240 ± 10% VAC Wall Power Supply
-R 1RU Rack Mounting
*+10˚C to +40˚C; 2 km maximum elevation; 90% maximum humidity; Specifications subject to change without notice
2009-8487P Manual, Rev. A Page 4 11/11/13
2.0 Installation
2.1 Mechanical
The 2009-8487P is packaged in an aluminum extrusion. The -R option is mounted on a 1 3/4” X 19” panel that
can be mounted to a rack using the 4 holes at the ends (See Figure 2.1).
2.1.1 Cleaning Instructions
Wipe the exterior with a dry, soft cloth. Use no detergent or cleaning chemicals.
EXTRUSION
FRONT SCREWS (4EA)
FRONT PANEL
RACK MOUNT PANEL (FOR -R MODELS ONLY)
C
ROSS
T
ECHNOLOGIES, INC.
2009 TEST DOWNCONVERTER
DC ALARM
REAR SCREWS (4EA)
REAR PANEL
FIGURE 2.1 Model 2009-8487P Assembly (-R option shown)
2.2 Indicators
Figure 2.2 shows front panel indicators.
DS1 - DC POWER LED
Lights green when DC
power is present.
DS2 - ALARM LED
Lights red when PLL
comes out of lock.
CROSS TECHNOLOGIES, INC.
DC ALARM
2009 TEST CONVERTER
FIGURE 2.2 Model 2009-8487P Front Panel Indicators
2009-8487P Manual, Rev. A Page 5 11/11/13
2.3 Input / Output Signals
Figure 2.3 shows the input and output signals to the 2009-8487P.
J1 - IF IN/OUT
The 67 MHz input/output.
This must be a “clean” input with
no image or other frequency
present. The maximum input
level is -5 dBm. This is a 50Ω,
SMA, female connector.
J3 - DC POWER
+15VDC Input, 400 mA (-P models ONLY.)
J2 - RF IN/OUT
The 8487 MHz input/output.
This must be a “clean” input
with no image or other
frequency present. The
maximum input level is -5 dBm.
This is a 50Ω, SMA, female
connector.
GND +15 to +18
DC POWER
IF
RF
J1 J3 J2
C
ROSS TECHNOLOGIES, INC.
+DC IN
+15V, 300 ma
FIGURE 2.3 Model 2009-8487P Rear Panel Inputs and Outputs
2.4 Accessing the PC Card
There are NO USER JUMPERS or other on-card controls. ALTHOUGH IT IS NOT RECOMMENDED AND
MAY VOID THE WARRANTY the following shows how to remove the printed circuit board (PCB) from the
extrusion:
1. Always remove power when installing or removing the PCB from the extrusion.
2. Remove four (4) rear panel screws (see Figure 2.1).
3. Gently pull the rear panel and PCB assembly completely out of the extrusion.
4. To install the PCB, gently push the rear panel and PCB assembly completely into the extrusion
(make sure the shield goes in the lower channel and the PCB in the next channel above that) and that
the front panel indicators line up with the front panel holes.
5. Install four (4) rear panel screws.
2.5 Installation / Operation
2.5.1 Installing and Operating the 2009-8487P
1. For Option -P models, connect one end of the Wall Power Supply to the 2009-8487P
DC Power In, J3, and the other end to 115 VAC, 60 Hz (Figure 2.3).
2. Connect a -5 dBm, maximum, signal to IF IN, J1 or RF IN, J2 (Figure 2.3).
3. Connect the IF OUT, J2, to the receiver under test (Figure 2.3).
4. Be sure DS1 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2).
2009-8487P Manual, Rev. A Page 6 11/11/13
3.0 Environmental Use Information
A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions
located in the user manual furnished by the manufacturer of your equipment rack.
B. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition
does not exist due to uneven weight distribution.
C. Elevated operating ambient temperature - If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack may be greater than room ambient temperature.
Therefore, consideration should be given to Tmra.
D. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised. Additional space between units
may be required.
E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of circuits could have on over current protection and supply wiring.
Appropriate consideration of equipment name plate rating should be used, when addressing this concern.
F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connection to the Branch
(use of power strips).
G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed.
If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED
prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS
emission problems.
2009-8487P Manual, Rev. A Page 7 11/11/13
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
Printed in USA
2009-8487P Manual, Rev. A Page 8 11/11/13
/