Hunter 32200 User manual

Category
Mobile phones
Type
User manual

This manual is also suitable for

43052-01 04/27/2007 1 © 2007 Hunter Fan Co.
www.hunterfan.com
Evaporative Humidier
Model 32200, 38200
Read and save these instructions.
ENGLISH
See page 2
ESPAÑOL
Vea la página 13
43052-01 04/27/2007 2 © 2007 Hunter Fan Co.
READ AND SAVE THESE INSTRUCTIONS
How The Hunter®
Evaporative Humidier Works
Important Safety Instructions:
Read all instructions before
using this humidier.
1. This humidifier may not work properly
on an uneven surface. ALWAYS place this
humidier on a rm, level, and water resis-
tant surface. ALWAYS place the humidier
at least six (6) inches away from walls and
heat sources such as stoves, radiators, or
heaters.
2. ALWAYS place the humidier in an area that
is out of the reach of children.
3. Before using the humidier, extend the cord
and inspect for any signs of damage. DO
NOT use the product if the cord has been
damaged.
4. This product has a polarized plug (one
blade is wider than the other) as a safety
feature. This plug will t into a polarized
outlet only one way. If the plug does not t
fully into the outlet, reverse the plug. If it still
does not t, contact a qualied electrician.
DO NOT attempt to defeat or override this
safety feature.
5. ALWAYS UNPLUG AND EMPTY the humidi-
er when it is not in operation or while it is
being cleaned.
6. DO NOT tilt or move the humidier while it
is in operation. Never move the humidier
while there is water in the tank. Empty the
water tank, turn o, and unplug the unit
before moving.
7. In addition to routine maintenance which
may be required, this humidier requires
seasonal cleaning. Refer to and follow
CLEANING THE HUMIDIFIER AND THE WA-
TER TANK instructions.
Thank you for purchasing The Care Free
®
Humidifier Evaporative Humidifier by
Hunter Fan Company. Please read and save
these instructions to receive the maximum
benet and performance from your humidi-
er.
The Hunter® Evaporative Humidier has a unique patented design with several innovative features:
• Built-inAntimicrobialProperties–Theplasticpartsandthelterhavebuilt-inantimicrobialprop-
erties to inhibit the growth of bacteria, mold and fungi that may aect these parts.
• NoWhiteDust–TheHunter® Evaporative Humidier produces no white dust that can settle on
furniture or be inhaled.
NOTE: This product contains antimicrobial properties which are built-in to inhibit the growth of
bacteria which may aect the plastic and lter in the humidier. These properties do not extend
to the water, humidied air or users. Conduct routine cleaning and maintenance based upon use
and individual conditions.
NOTE: You may notice mineral deposits accumulating in the tank base. This is normal and does
not aect performance. If you would like to clean these deposits away, please see CLEANING THE
HUMIDIFIER AND WATER TANK.
43052-01 04/27/2007 3 © 2007 Hunter Fan Co.
Humidier Parts
Figure 1
Base
Wick
Water Tank
Main Housing
Tank Tote
Tank Fill Cap
Power/Speed
Control
43052-01 04/27/2007 4 © 2007 Hunter Fan Co.
Figure 2
Using Your Humidier
1. Remove the Hunter® Evaporative Humidier from its packaging.
2. Place the humidier on a hard, at, water resistant surface. Always place the humidier at least
six (6) inches away from walls and sources of heat.
3. Make sure the Power/Speed Control is in the ‘OFF’ position. NOTE: The Power/Speed Control should
always be o before unplugging the humidier, moving the humidier, or relling the water tank.
See Figure 2.
Figure 3
Wick, properly
seated
O
F
F
4. Lift the Main Housing to ensure the Wick is properly seated, resting on the bottom of the base and
not tilted or otherwise out of position. See Figure 3. Place the Main Housing back on the Base.
Power/Speed Control
43052-01 04/27/2007 5 © 2007 Hunter Fan Co.
4. Grasp the Water Tank by its Tank Tote and remove it from the Base.
5. Turn the Water Tank upside-down and remove the Tank Fill Cap. See Figure 4.
Twist to open
Figure 4
6. Fill the Water Tank with water, return the Tank Fill Cap to its position and tighten it, and return the
Water tank to the Base.
7. Plug the humidiers Power Cord into a standard household power outlet.
8. Turn the Power/Speed Control to your desired humidier fan speed. See Figure 5.
O
F
F
Figure 5
43052-01 04/27/2007 6 © 2007 Hunter Fan Co.
Cleaning The Humidier And The Water Tank
Relling The Water Tank
1. When the water tank level is low, turn the humidier ‘OFF’, and unplug.
2. Remove the tank and take it to the sink or tub to rell.
3. Turn the tank upside down and unscrew the tank cap by turning it counterclockwise. Empty the tank,
rell with fresh cool water (never use hot water), and replace the tank cap. Be sure not to overll the
tank as water damage may occur to furniture or ooring due to spillage. HUNTER WILL NOT ACCEPT
RESPONSIBILITY FOR DAMAGE TO PROPERTY CAUSED BY WATER SPILLAGE.
4. Carry the tank back to the humidier. Turn the tank upright and place it on the humidier. Be sure
that the tank is seated properly in the base. If the tank is properly located on the base, you will
see air bubbles owing up into the tank.
Many regions have hard water with high concentrations of minerals. When water evaporates from The
Hunter® Evaporative Humidier, minerals may be left behind. These minerals can form a hard white
scale which can be removed by following the cleaning instructions. The frequency of cleaning due
to mineral build up can vary depending upon the quality of water you may have.
Refer to Figure 1 for part names.
1. Turn the humidier OFF and unplug the unit.
2. Lift the main housing and remove the water dispersion tray and the wick. The motor is attached
to the main housing. Do not place the motor near water. Do not use a wet towel on the motor or
motor housing as electrical shock may occur.
3. Replace the humidiers wick every 4 - 8 weeks or when it has turned brown.
4. Remove the water tank from the base and empty any water that is left in the tank. Soak the base
in a mixture of one (1) gallon of water and eight (8) ounces of vinegar for 20 minutes. The base is
dishwasher safe.
5. After soaking, wipe the base with a soft cloth or sponge to remove any mineral build up. Rinse
with clean water several times. If you are planning on storing the humidier, be sure the base
is completely dry.
6. Fill the water tank with one (1) gallon of water and eight ounces of undiluted white vinegar. Re-
place the tank cap and shake the tank vigorously until all interior surfaces of the tank have been
exposed to the water/vinegar mixture.
7. Empty the tank of the water/vinegar mixture. Rinse it several times with clean water and then
replace the tank cap. If you are planning on storing the humidier, dry it inside and out, leaving
the cap o to allow the tank to completely dry. Continue to clean the other parts of your humidi-
er.
8. Wipe the surfaces of the main housing with a soft cloth.
9. Once all the parts are clean, reassemble the humidier, and follow the USING YOUR
HUMIDIFIER to continue use. If you are storing the humidier, make sure the parts are completely
dry, reassemble, and store in a dry location.
43052-01 04/27/2007 7 © 2007 Hunter Fan Co.
NOTE: The humidiers Wick is made of paper and is NOT washable.
Over time, minerals in your water will build up in the humidier’s Wick, degrading its ability to absorb
water and reducing the humidiers output. Therefore, you should replace the humidiers Wick every
4 - 8 weeks, depending on the hardness of your water.
1. Turn the humidier OFF and unplug the unit.
2. Lift the Main Housing, remove it from the Base, and set it aside.
3. Grasp the humidier Wick, hold it over the base, and squeeze the water from it. This will keep
water from dripping onto your oor. You may also want to wrap the Wick in a towel to keep it
from dripping while you transport it to disposal.
4. Replace the old Wick with a new Hunter humidier Wick, number 31911. New Wicks are available
at your local Hunter retailer or at www.hunterfan.com.
5. Ensure the Wick is properly seated, resting on the bottom of the base and not tilted or otherwise
out of position.
6. Return the Main Housing to its position on the Base. Make certain the Main Housing is properly
seated on the Base.
7. Plug the humidier’s Power Cord into a standard household power outlet and turn the Power/Speed
Control to your desired setting.
Replacing the Humidier Wick
43052-01 04/27/2007 8 © 2007 Hunter Fan Co.
To obtain a service part for your humidier, call customer service at 1-888-830-1326 or e-mail us at
techsupport@hunterfan.com. Please be prepared to tell the operator the model number of your
humidier and the name of the part you need to replace and the part number. Refer to Figure 1 for
part names.
Service Parts
32200
Model No.
Base
Water
Tank
Knob A
Tank Cap
Filter
31911
97676
97678 76257
87843
43052-01 04/27/2007 9 © 2007 Hunter Fan Co.
To learn more about Hunter Fan Company products, please see our web page at:
www.hunterfan.com
Other Home Comfort Products from Hunter
Hunter Original
®
QuietFlo™
True HEPA Air Purier
Programmable
Thermostat
43052-05 04/27/2007 28 © 2007 Hunter Fan Co.
HUNTER FAN COMPANY
2500 FRISCO AVENUE
MEMPHIS, TN 38114, USA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Hunter 32200 User manual

Category
Mobile phones
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages