Aeg-Electrolux S98820-4IREW User manual

Category
Drink coolers
Type
User manual
Contents
Safety Instructions / Standards 45
Disposal of packaging and old appliances 46
Installation / Installation site 47
Your cooler needs air 48
Installation 48
Electrical connection 49
Product description 50
Interior fittings 50
User panel 50
Commissioning – setting temperature, switching off 50
Adjusting storage racks 51
Adjusting the temperature zone divider 52
Changing the light fitting 52
Proper loading 53
Ideal drinking temperatures 53
Defrosting 53
Cleaning 53
Energy-saving tips 54
What to do if ….Troubleshooting 54
Guarantee 56
Operating noises 56
44
Dear Customer
Please read these instructions carefully before starting to use your wine cooler. They
contain important information about the safe operation, installation and maintenance
of your appliance.
Please keep them for reference and pass them on to any subsequent user.
Safety Instructions
This refrigerator conforms to recognised technical regulations and to the EC guide-
line /EEC (low voltage guideline). It has been checked for compliance with electrical
safety regulations in accordance with EMC guideline 89/336/EEC and EN
55014.1993.
. Electrical safety (shock-hazard protection) must be effected as part of the instal-
lation procedure.
. Mains voltage 230V/50Hz.
. This appliance should be used for domestic purposes only in accordance with the
user instructions.
. If you have received a faulty appliance, contact your supplier immediately.
. Repairs and modifications must only be carried out by a qualified service engineer.
. Disconnect from the mains when cleaning; pull out the plug or deactivate the fuse.
Never pull the plug out of the socket by the cable or with wet hands. Always take
hold of the plug itself and pull it straight out of the socket.
. This appliance is CFC- and HFC-free and contains small quantities of Isobutane
(R600a), an environmentally friendly coolant.
. You must ensure that the cooling circuit is undamaged when handling this appli-
ance. However, if it becomes damaged, avoid proximity to open fires and heat
sources of all kinds. The room in which the appliance is located should be venti-
lated for a few minutes.
. Never use an appliance with a damaged circuit.
. Ensure that the ventilation openings to and from a built-in appliance are never
blocked or covered. No liability will be accepted for any damage incurred owing
to misuse of the appliance or as a result of repairs carried out by unqualified
personnel. In this case neither the guarantee nor any other liability claims will
apply.
. In the interests of safety, faulty connection cables for this appliance must be repla-
ced by your local Service Force Centre or similarly qualified personnel.
. Warning: Do not operate any electrical appliances inside the cooler.
45
Disposal
Information about the appliance packaging
Dispose of your appliance packaging properly. None of the packaging materials
used are harmful to the environment and they may be re-used.
About the materials: the plastics may also be recycled and are identified as follows:
>PE< for polyethylene e.g. in the outer casing and internal pockets.
>PS< for polystyrene foam, e.g. in padding. Essentially CFC-free.
The cardboard used is made from recycled paper and should also be put out for old
paper collection.
Disposal of old appliances
Refrigeration equipment must be properly disposed of in a way which protects the
environment. This applies to your old appliance and to your new unit once it has
reached the end of its service life.
Warning: Please ensure that old, worn appliances are rendered unusable before
disposal by removing the plug, cutting the network cable, and removing or de-
stroying any snap fastenings or bolts. You will thus prevent children from locking
themselves in the appliance during play (risk of suffocation) or endangering their lives
in any other way.
Disposal instructions:
. The appliance must not be disposed of in the dustbin or with normal household
rubbish.
. The coolant circuit, particularly the heat exchanger at the back of the appliance,
must not be damaged.
. The symbol on the product or its packaging indicates that this product is not
to be handled as normal household waste but is to be taken to a recycling collec-
tion point for electrical and electronic goods. By correctly disposing of this pro-
duct you are contributing to the protection of the environment and to the health of
your fellow human beings. Improper disposal endangers health and the environ-
ment. Further information about the recycling of this product may be obtained
from your town hall, refuse collection department or the store where you purcha-
sed the product.
46
Installation
Installation site
The appliance should be positioned in a well-ventilated, dry room. The ambient tem-
perature will influence energy consumption and the proper functioning of the unit.
For this reason, the appliance
. Should not stand in direct sunlight;
. Should not stand near a radiator, a stove or any other heat source;
. Should be located only where the ambient temperature is compatible
with the climatic classification of the appliance.
You will find the climatic classification on the nameplate inside the appliance on the
top right-hand side.
The following table specifies the ambient temperature range for each climatic clas-
sification:
Climatic classification for an ambient temperature of
SN +10 to +32° C
N +16 to +32° C
ST +18 to +38° C
T +18 to +43° C
To prevent the appliance from heating up, ensure that an adequate ventilation gap
is retained and install a suitable thermal insulation panel. An adequate flow of air to
and from the cooling system must be ensured.
47
The cooler needs air
The cooler door seals the installed unit almost completely, so an air vent must be pro-
vided in the base of the housing. Warmed air must be conducted via the ventilation
shaft to the rear wall of the housing and then expelled upwards. The ventilation
channels should measure at least 200 cm
2
in cross-section.
Warning! To ensure the proper functioning of the appliance, air vents should never
be blocked or covered.
Installation
Scale drawing
48
min. 200 cm
2
min. 200 cm
2
50
200 cm
2
200 cm
2
874880
560 min.
550 min.
547
566
873
50
After installing the unit, and particularly if the door hinge is reversed, please ensure
that the door seal is tight all round. An imperfect door seal can lead to increased
condensation and thus to higher energy consumption (see the section headed
“Troubleshooting”).
Electrical connection
A properly installed socket outlet with earthing contact is required for electrical con-
nection, positioned so that it is possible to pull out the mains plug.
The socket outlet with earthing contact used to connect the appliance should be
positioned on the left or right-hand side adjacent to the housing.
Electrical fuse protection of at least 10/16 amperes must be provided. If the socke
is no longer accessible once the appliance has been built-in, suitable measures
must be taken during electrical installation to ensure that the appliance can be dis-
connected from the mains (fuse, LP [line protection] contact opening width of at
least 3 mm).
Before operating the appliance, check the data plate to ensure compliance of the
connection voltage and type of frequency with the mains network values at the
installation site.
e.g. AC 220 … 240 V 50 Hz or
220 … 240V~ 50 Hz
(i.e. 220 to 240 volt alternating current, 50 Hertz)
The dataplate is located inside the appliance on the top right-hand side.
49
Product description
1 Control panel
2 Storage racks (adjustable)
3 Temperature zone divider (adjustable)
Control panel
1 Appliance on/off
Press for at least 3 seconds.
2 Select upper zone temperature (5 to 18° C, adjustable)
Recommendation: 5–12° C (ideal for white wine, see page 11)
Press for at least 3 seconds indicator flashes
The temperature can be adjusted in steps.
2a Select lower zone temperature (5 to 18°C, adjustable)
Recommendation: 1218° C (ideal for red wine, see page 11)
The temperature set for the lower zone must always be the
same as or higher than that in the upper zone.
50
32 2a
1 4
2
3
2
1
3 Supercool
Press for 3 seconds the yellow pilot light illuminates.
The appliance cools the upper zone for 24 hours at +5° C
and then automatically at the set temperature.
4 Interior light switched on permanently:
Press for 3 seconds ON
Interior light on only while the door is open:
Press for 3 seconds OFF
If the door is kept open for longer than 5 minutes, an acoustic door alarm will
sound. This can be switched off by briefly pressing any button.
To adjust storage racks
The height of the storage racks is adjustable.
Pull the shelf forwards, lift on the door side and remove.
Reverse this procedure to replace the shelf at a different level.
51
To adjust the temperature zone divider
The temperature zone divider can be raised or lowered by 1 position.
Pull forwards away from the rear wall, and lift on door side.
Reverse this procedure to replace at a different level.
Please ensure that the rear section of the temperature zone divider slots into the
groove provided in the rear wall.
To change LED lighting
Click off the LED light cover. Loosen the plug of the LED light fitting. Reverse this
procedure to insert a new LED light fitting.
Note: Please use only original LED light fittings provided by the manufacturer.
52
Proper loading
The appliance is separated into 2 adjustable temperature zones (both adjustable
from 5 to 18° C):
Top compartment white wine, champagne, sparkling wine, rosé wine.
Bottom compartment red wine
Please ensure that the temperature set for the bottom compartment is always at
least the same as or higher than that in the top compartment.
Ideal drinking temperatures*
6–8° Champagne, sparkling wines, Chasselas, Riesling, Sauvignon
Blanc, young Chardonnays and sweet wines, all rosé wines
8–10° Mature Chardonnays and Sauternes
13 15° Gamay, young Merlots, young Pinot Noir wines
15 17° Young Bordeaux, light Cabernet, Barbera, Merlot
16 18° Big Burgundies, Bordeaux, Italian, Spanish and Californians, etc.
17– 18° Barolo, Reciotto Amarone
(The lower temperature is suitable for more simple wines, and the higher for the
more complex, better quality wines of each category).
* Source: Mövenpick
Defrosting
The cooler defrosts automatically.
The evaporator behind the rear wall of the cooler defrosts automatically. The con-
densate collects in the drainage channel behind the rear wall of the cooler, and flows
through the drainage hole into the drip tray by the compressor where it evaporates.
Cleaning and maintenance
For reasons of hygiene, the interior of the appliance, including all internal fitments,
should be cleaned regularly.
Warning! Because of the risk of electric shock, the appliance should not be con-
nected to the mains during cleaning. Before cleaning, switch off the appliance, pull
out the mains plug or deactivate and/or remove the fuse.
53
Never steam-clean the appliance. Dampness may penetrate the electrical compo-
nents, creating the risk of an electric shock. Hot steam may damage the plastic
components. The appliance must be dry before it is used again.
Caution! Plastic components may be attacked by essential oils and organic sol-
vents such as fruit juices and the acids in butter, as well as by detergents containing
vinegar. Such substances should not come into contact with appliance compo-
nents. Do not use abrasive cleaning agents.
Energy-saving tips
. Do not install the appliance near stoves, radiators, or any other sources of heat. If
the ambient temperature rises, the compressor operates more frequently and for
longer.
. Ensure that the appliance is adequately ventilated. Never cover air vents.
. Only open the door for as long as necessary.
What to do if…
Troubleshooting
Any malfunction will probably be due to a minor fault which you will be able to
rectify yourself with the aid of the following instructions. Do not attempt any more
extensive repairs yourself, should the following information prove unhelpful in solving
a particular problem.
Warning! Repairs to the wine cooler should only be carried out by qualified person-
nel. Repairs undertaken incorrectly may cause considerable risk to the user. Contact
your local Service Force Centre.
54
Appliance doesn’t work.
Inadequate cooling
chamber temperature.
Interior light doesn’t work.
The compressor doesn’t
cut in immediately after
changing the temperature
setting.
Error message F1 on
control panel.
Error message F2 on
control panel.
Error message F3 on
control panel.
Appliance is not switched
on.
Mains plug is loose or
not plugged in.
Fuse has triggered or is
defective.
Socket is defective.
Temperature has not
been properly set.
Door was open for a
long period.
The appliance is positio-
ned next to a heat source.
LED is defective.
This is normal and not
due to a fault.
Upper sensor defective.
Lower sensor defective.
Fan defective.
Switch on.
Insert the mains plug.
Check fuse and replace if
necessary.
Faults with the mains
supply must be repaired by
a qualified electrician.
Please see under
“Commissioning”.
Only open door for as long
as necessary.
Please see under
“Installation site”.
Please see under “LED
lighting”.
The compressor cuts in
automatically after a short
time.
Contact customer service.
Contact customer service.
Contact customer service.
Fault Possible cause Solution
55
Service and spare parts
In the event of your appliance requiring service, or if you wish to purchase spare
parts, please contact your local Service Force Centre by telephoning:
08705 929929
Your telephone call will be automatically routed to the Service Force Centre covering
your post code area.
For the address of your local Service Force Centre and further information about
Service Force, please visit the website at www
.serviceforce.co.uk
Before calling out an engineer, please ensure you have read the details under the
heading “Something Not Working.
When you contact the Service Force Centre you will need to give the following details:
1. Your name, address and post code
2. Your telephone number
3. Clear and concise details of the fault
4. The model and serial number of the appliance (found on the rating plate)
5. The purchase date
Please note that a valid purchase receipt or guarantee documentation is
required for in-guarantee service calls.
Customer care department
For general enquiries concerning your AEG appliance or for further information on
AEG products, please contact our Customer Care Department by letter or telepho-
ne at the address below or visit our website at www
.aeg.co.uk
Major Appliances
Addington Way
Luton
Bedfordshire
LU4 9QQ
08705 950 950(*)
* calls to this number may be recorded for training purposes.
56
Guarantee conditions
Standard Guarantee Conditions
AEG offer the following guarantee to the first purchaser of this appliance:
1. The guarantee is valid for 12 months commencing when the appliance is hand-
ed over to the first retail purchaser, which must be verified by purchase invoice or
similar documentation.
1. The guarantee does not cover commercial use.
2. The guarantee covers all parts or components which fail due to faulty workman-
ship or faulty material. The guarantee does not cover appliances where defects
or poor performance are due to misuse, accidental damage, neglect, faulty instal-
lation, unauthorised modification or attempted repair, commercial use or failure to
observe requirements and recommendations set out in the instruction book.
3. This guarantee does not cover such parts as light bulbs, removable glassware,
or plastic.
4. Should guarantee repairs be necessary the purchaser must inform the nearest
customer service office (AEG's service or authorised agent). AEG reserves the
right to stipulate the place of repair (i.e. the customer's home, place of installati-
on or AEG workshop).
5. The guarantee or free replacement includes both labour and materials.
6. Repairs carried out under guarantee do not extend the guarantee period for the
appliance. Parts removed during guarantee repairs become the property of AEG.
7. The Purchaser's statutory rights are not affected by this guarantee.
European Guarantee
. If you should move to another country within Europe then your guarantee moves
with you to your new home subject to the following qualifications:
. The guarantee starts from the date you first purchased your product
. The guarantee is for the same period and to the same extent for labour and parts
as exists in the new country of use for this brand or range of products
. This guarantee relates to you and cannot be transferred to another user
. Your new home is within the European Community (EC) or European Free Trade
Area
. The product is installed and used in accordance with our instructions and is only
used domestically, i.e. a normal household
. The product is installed taking into account regulations in your new country
57
Before you move please contact your nearest Customer Care centre, listed below,
to give them details of your new home. They will then ensure that the local Service
Organisation is aware of your move and able to look after you and your appliances.
France Senlis +33 (0)3 44 62 29 29
Germany Nürnberg +49 (0)800 234 7378
Italy Pordenone +39 (0)800 117511
Sweden Stockholm +46 (0)8 672 5360
UK Luton +44 (0)8705 950 950
Operating Noises
Noises which are entirely normal
The chill cabinet is cooled by a compressor (refrigeration aggregate). The compressor
pumps coolant through the cooling system, producing operating noises. Even when
the compressor cuts out, noises caused by changes in temperature and pressure
are unavoidable.
This cooler is fitted with a quiet compressor and a low-noise cooling circuit
designed in line with the latest technical developments. However, a certain
level of noise, dependent on the size of the cooler, is inevitable. Operating noise will
be most audible immediately after the compressor cuts in. It becomes quieter as the
operating period continues.
Noises which are not normal
Unusual noise is normally the result of improper installation. The cooler must be
installed or built-in so that it is level and stable. Under no circumstances must tubing
come into contact with a wall, other furniture or with another tubing.
Where coolers are installed in open-plan kitchens or in partition walls, the
level of operating noise will be heard more acutely. However, this is due to
the surrounding architecture and not to a fault with the cooler.
58
Description Cause Comment
Droning Cooling system Normal operating noise of the cooling
system. The level is dependent on
the size of cooler.
Humming Fan Normal operating noise of the fan.
Gurgling Cooling circuit Normal operating noise as coolant
Babbling flows through the circuit.
Murmuring
Hissing Cooling circuit Normal operating noise as coolant is
injected into the condenser.
Cracking Cooler housing Normal as materials expand and
contract due to temperature variations
(e.g. plastics, insulation).
59
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104

Aeg-Electrolux S98820-4IREW User manual

Category
Drink coolers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI