Quikrete 158501 Installation guide

Type
Installation guide

Quikrete 158501 is a non-shrink general purpose grout that is used for grouting steel columns, bearing plates, precast concrete, and other anchoring conditions that require high in-service strength. It is a high strength, non-metallic, Portland cement based material with expansive additives that make it stable and capable of handling high load transfers. Quikrete 158501 is easy to use, simply mix with water and pour into place. It is self-leveling and will flow into even the tightest spaces. It is also non-corrosive and will not damage metal or concrete.

Quikrete 158501 is a non-shrink general purpose grout that is used for grouting steel columns, bearing plates, precast concrete, and other anchoring conditions that require high in-service strength. It is a high strength, non-metallic, Portland cement based material with expansive additives that make it stable and capable of handling high load transfers. Quikrete 158501 is easy to use, simply mix with water and pour into place. It is self-leveling and will flow into even the tightest spaces. It is also non-corrosive and will not damage metal or concrete.

N
N
N
O
O
O
N
N
N
-
-
-
S
S
S
H
H
H
R
R
R
I
I
I
N
N
N
K
K
K
G
G
G
E
E
E
N
N
N
E
E
E
R
R
R
A
A
A
L
L
L
P
P
P
U
U
U
R
R
R
P
P
P
O
O
O
S
S
S
E
E
E
G
G
G
R
R
R
O
O
O
U
U
U
T
T
T
P
P
P
R
R
R
O
O
O
D
D
D
U
U
U
C
C
C
T
T
T
N
N
N
O
O
O
.
.
.
1
1
1
5
5
5
8
8
8
5
5
5
-
-
-
0
0
0
1
1
1
PRODUCT USE
Typical applications for QUIKRETE
®
Non-Shrink General Purpose
Grout include grouting of:
• Steel columns
• Bearing plates
• Precast concrete
• Other anchoring conditions that require high in-service
strength
The non-shrink characteristics of Non-Shrink General Purpose Grout
make it stable and capable of handling high load transfers.
NOTE: This product is not for use in precision grouting of machinery.
(For precision grouting of machinery use QUIKRETE Non-Shrink
Precision Grout #1585-00.)
SIZES
• QUIKRETE
®
Non-Shrink General Purpose Grout - 50 lb (22.7 kg)
bags
YIELD
• Each 50 lb (22.7 kg) bag will yield 0.45 cu ft (12.7 L) at flowable
consistency.
TECHNICAL DATA
APPLICABLE STANDARDS
ASTM International
• ASTM C109/109M Standard Test Method for Compressive Strength
of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube
Specimens)
• ASTM C827 Standard Test Method for Change in Height at Early
Ages of Cylindrical Specimens of Cementitious Mixtures
• ASTM C939 Standard Test Method for Flow of Grout for Preplaced-
Aggregate Concrete (Flow Cone Method)
• ASTM C1090 Standard Test Method for Measuring Changes in
Height of Cylindrical Specimens from Hydraulic-Cement Grout
• ASTM C1107 Standard Specification for Packaged Dry, Hydraulic-
Cement Grout (Nonshrink)
• ASTM C 1437 Standard Test Method for Flow of Hydraulic Cement
Mortar
U.S. Army Corps of Engineers (USACE) - CRD 621
PHYSICAL/CHEMICAL PROPERTIES
QUIKRETE
®
Non-Shrink General Purpose Grout complies with the
physical requirements of ASTM C1107 and CRD 621 when tested at
72 degrees F (22 degrees C).
SURFACE PREPARATION
• Surfaces to receive the grout must be free of any type of foreign
material (grease, oil, paint, dust or efflorescence)
• It may be necessary to roughen smooth surfaces or etch old ones
with acid. The area should be flushed and soaked with clean water.
• Prior to grouting, remove all standing water.
• Place the grout quickly and continuously using light rodding to
eliminate air bubbles
MIXING
QUIKRETE
®
Non-Shrink General Purpose Grout should be
mechanically mixed for a minimum of 5 minutes. Add only enough
water to achieve the flow required for the application. Approximate
water contents listed in Table 2 are only a guideline. Do not add more
water than the amount needed to produce a 20 second flow per Test
Method ASTM C939.
CURING
A damp cure of at least 3 days is necessary to control the non-shrink
characteristics and maintain strength levels.
PRECAUTIONS
• Additions of cement or other materials will eliminate the designed
product qualities
• Water quantities may be affected by temperature, mixing method
and batch size
• QUIKRETE
®
Non-Shrink General Purpose Grout should not be re-
tempered
• Mix no more grout than can be placed in 15 minutes.
• Grout temperature should be maintained from 50 - 90 degrees F (10
- 32 degrees C). Use cold water in hot weather or hot water in cold
weather to achieve desired grout temperature. Do not pour grout if
PRODUCT DESCRIPTION
QUIKRETE
®
Non-Shrink General Purpose Grout is a high strength, non-metallic,
Portland cement based material with expansive additives designed for grouting
steel columns, bearing plates, pre-cast concrete, and anchoring applications.
Non-Shrink Grouting
03 62 00
DIVISION 3
temperature is expected to go below 32 degrees F (0 degrees C)
within a 12 hour period.
TABLE 1
TYPICAL PHYSICAL PROPERTIES OF FRESHLY MIXED GROUT,
ASTM C1107
Consistency Plastic
Temperature 72°F (22°C)
Compressive strength, ASTM C109 modified per ASTM C1107
1 day 3,000 psi (20.7 Mpa)
7 days 9,000 psi (62.1MPa)
28 days 10,000 psi (68.9 MPa)
Height change, ASTM C1090
@ 1, 3, 7 & 28 days 0 - 0.2%
Height change, ASTM C827 0%
Consistency Flowable
Temperature 72°F (22°C)
Compressive strength, ASTM C109 modified per ASTM C1107
1 day 3,000 psi (20.7 Mpa)
7 days 8,000 psi (55.2 MPa)
28 days 9,000 psi (62.1 MPa)
Height change, ASTM C1090
@ 1, 3, 7 & 28 days 0 - 0.2%
Height change, ASTM C827 0.3%
Consistency Fluid
Temperature 72°F (22°C)
Compressive strength, ASTM C109 modified per ASTM C1107
1 day 2,000 psi (13.8 MPa)
7 days 6,000 psi (41.4 MPa)
28 days 8,000 psi (55.2 MPa)
Height change, ASTM C1090
@ 1, 3, 7 & 28 days 0 - 0.2%
Height change, ASTM C827 0.8%
TABLE 2
WATER REQUIREMENTS FOR 50 LB (22.7 KG) BAG
Method Volume
Plastic 1 gal (3.8 L)
Flowable 1 gal + 1 pt (4.3 L)
Fluid 1 gal + 3 pt (5.2 L)
WARRANTY
The QUIKRETE® Companies warrant this product to be of
merchantable quality when used or applied in accordance with the
instructions herein. The product is not warranted as suitable for any
purpose or use other than the general purpose for which it is
intended. Liability under this warranty is limited to the replacement of
its product (as purchased) found to be defective, or at the shipping
companies’ option, to refund the purchase price. In the event of a
claim under this warranty, notice must be given to The QUIKRETE®
Companies in writing. This limited warranty is issued and accepted in
lieu of all other express warranties and expressly excludes liability for
consequential damages.
The QUIKRETE® Companies
One Securities Centre
3490 Piedmont Rd., NE, Suite 130Atlanta, GA 30305
(404) 634-9100 • Fax: (404) 842-1425
* Refer to www.quikrete.com for the most current technical data, MSDS, and guide specifications
  • Page 1 1
  • Page 2 2

Quikrete 158501 Installation guide

Type
Installation guide

Quikrete 158501 is a non-shrink general purpose grout that is used for grouting steel columns, bearing plates, precast concrete, and other anchoring conditions that require high in-service strength. It is a high strength, non-metallic, Portland cement based material with expansive additives that make it stable and capable of handling high load transfers. Quikrete 158501 is easy to use, simply mix with water and pour into place. It is self-leveling and will flow into even the tightest spaces. It is also non-corrosive and will not damage metal or concrete.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI