Armstrong SDWP-001 User manual

Type
User manual
SDWP-001
Electronic touch panel cabinet lock
User manual
DIGIT PANEL:
Touch digits panel to activate the system.
Default code:
For 8-digit management: 12345678
For 6-digit user: 123456.
Security alarm:
If entering wrong code 3 times, digit panel will flash with alarm sound
“beep beep beep for 30 seconds. You are not able to enter any digit at this
moment until alarm off.
SET UP AUTO / MANUAL CLOSE MODE
The lock is set to auto-close mode initially.
To switch the auto / manual mode, press the
button A at back of the lock.
Auto-close mode (“ Beep beep sound):
The plunger will come out after 8 second.
Manual-close mode (“Beep” sound):
An user has to enter 6-digit user code, then the plunger will come out.
Modify code:
Change user’s code
After open the lock with user code Press “set” Enter “new 6 digit code Press OK
Plunger will come out if code Press “OK” button again Enter “6-digit” code again
changes successfully
Change management’s code
After open the lock with management’s code Press “set” Enter “new 8 digit code”
Press “OK” button again Enter “8-digit” code again Press “ OK” button
Plunger will come out if code changes successfully
**User code will default to 123456 after using management code to unlock
Lock and unlock (Under manual-close mode ):
To unlock
Enter 6 digit code Press “OK” button The plunger goes in to “Unlock”
To lock
Enter 6 digit code Press “OK” button The plunger comes out to “Lock
**When entering wrong code, press “SET” to erase and re-enter user code
Lock and unlock (Under auto-close mode ):
Using user 6-digit code
To unlock and lock
Touch digit panel to activate system Press 2 random digits Press user 6-digit code
Press “OK” button again to lock Press “OK” button to unlock
After 6 seconds, the plunger will come out automatically
Using management 8-digit code
To unlock and lock
Touch digit panel to activate system Press 2 random digits Press admin 8-digit code
Press “OK” button again to lock Press “OK” button to unlock
After 6 seconds, the plunger will come out automatically
**When enter admin 8-digit code to open lock, the users 6-digit code will default to 123456
Reset
Press button “B” to reset system. Management code will
default to 12345678 and user code will default to
123456
Low voltage alarm:
If voltage drops to 3.6V, digit panel will flash with alarm sound when you touch the
panel. It means to remind you that voltage is low and please change new batteries.
Put your finger on the panel for 3 seconds to exit alarm, and then enter your code to
unlock.
Emergency external power:
When voltage is below 3.6V, which is out of working voltage. You can put new 1.5V x 3 pcs in the
battery case and insert to the socket under the front case.
VOLTAGE
4.5V
WORKING
TEMPERATURE
0°C ~40°C
STATIC
CURRENT
45uA
WORKING
HUMIDITY
20% ~80%
Warning
Voltage input cannot be over than 6V
Risk of suffocation from small parts and packing materials!
·Screws, small parts and packing materials can be deadly playthings for children.
·Do not leave the packing materials and the contents lying around carelessly, and keep away from
children and babies.
Installation:
  • Page 1 1
  • Page 2 2

Armstrong SDWP-001 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI