Operator’s Manual
Stratos™Portable Plus
Compressor Nebulizer
System
Model Number: IRC 1730
TABLE OF CONTENTS
Part No 1150755 2 Stratos™Portable Plus
TABLE OF CONTENTS
SPECIAL NOTES ............................................... 5
INTRODUCTION .............................................. 6
REGISTER YOUR PRODUCT .............................. 7
FEATURES ....................................................... 8
TYPICAL PRODUCT PARAMETERS ................... 9
SUPPLEMENTAL INFORMATION ..................... 10
Compressor........................................................................................10
Extension Cords................................................................................10
HANDLING ................................................... 11
Shipping Instructions.........................................................................11
Unpacking............................................................................................11
Inspection............................................................................................11
SECTION 1—IMPORTANT SAFEGUARDS ......... 12
To Reduce the Risk of Electrocution: ..........................................13
SECTION 2—OPERATING INSTRUCTIONS ....... 17
Setup.....................................................................................................17
Treatment Instructions....................................................................19
SECTION 3—BATTERIES ................................. 21
TABLE OF CONTENTS
TABLE OF CONTENTS
Stratos™Portable Plus 3 Part No 1150755
Battery Specifications .......................................................................21
Conditioning the Battery.................................................................23
Using the Battery...............................................................................24
Charging the Battery ........................................................................25
SECTION 4—CLEANING AND DISINFECTING ... 27
Cleaning the Nebulizer ....................................................................27
Cleaning the Mouthpiece.................................................................29
Changing the Nebulizer ...................................................................29
Cleaning the Compressor ...............................................................29
SECTION 5—MAINTENANCE .......................... 31
Routine Care......................................................................................31
Storage.................................................................................................32
Filter Care...........................................................................................32
SECTION 6—TROUBLESHOOTING ................... 33
LIMITED WARRANTY .................................... 35
Stratos™Portable Plus 4 Part No 1150755
WARNING
DO NOT USE THIS PRODUCT OR ANY AVAILABLE
OPTIONAL EQUIPMENT WITHOUT FIRST
COMPLETELY READING AND UNDERSTANDING
THESE INSTRUCTIONS AND ANY ADDITIONAL
INSTRUCTIONAL MATERIAL SUCH AS OWNER’S
MANUALS, SERVICE MANUALS OR INSTRUCTION
SHEETS SUPPLIED WITH THIS PRODUCT OR
OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO
UNDERSTAND THE WARNINGS, CAUTIONS OR
INSTRUCTIONS, CONTACT A HEALTHCARE
PROFESSIONAL, DEALER OR TECHNICAL
PERSONNEL BEFORE ATTEMPTING TO USE THIS
EQUIPMENT - OTHERWISE, INJURY OR DAMAGE
MAY OCCUR.
ACCESSORIES WARNING
Invacare products are specifically designed and
manufactured for use in conjunction with Invacare
accessories. Accessories designed by other manufacturers
have not been tested by Invacare and are not
recommended for use with Invacare products.
SPECIAL NOTES
Part No 1150755 5 Stratos™Portable Plus
SPECIAL NOTES
Signalwordsareusedinthismanualandapplytohazardsor
unsafepracticeswhichcouldresultinpersonalinjuryor
propertydamage.Refertothetablebelowfordefinitionsof
thesignalwords.
NOTICE
The information contained in this document is subject to
change without notice.
SIGNAL
WORD
MEANING
DANGER
Danger indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury.
WARNING
Warning indicates a potentially hazardous situation which, if
not avoided, could result in death or serious injury.
CAUTION
Caution indicates a potentially hazardous situation which, if
not avoided, may result in property damage.
INTRODUCTION
Stratos™Portable Plus 6 Part No 1150755
INTRODUCTION
YourInvacareStratosPortablePlusCompressorNebulizer
Systemisthelatestinportablecompressornebulizer
technology.Thepurposeofthenebulizersystemistoconvert
yourliquidmedicationintoafinemistthatcanbedrawninto
yourlungstorelieveyourrespiratorycondition.The
nebulizersystemisveryportableandlightweight.Foreven
greaterconvenience,askyourdealerabouttheoptional
batterypackthatissoldseparately.
Tomaximizeyourbenefitfromthenebulizersystem,we
recommendyoureadandunderstandtheinformationinthe
operatingmanual.Byfollowingyourdoctorsadviceand
thesesimpleinstructions,thenebulizersystemwillbecomea
valuablepartofyourdailytreatmentroutine.
REGISTER YOUR PRODUCT
Part No 1150755 7 Stratos™Portable Plus
REGISTER YOUR PRODUCT
The benefits of registering include:
1. Safeguarding your investment.
2. Ensuring long-term maintenance and servicing of your product.
3. Receiving updates with product information, maintenance tips
and industry news.
Register ONLINE at
warranty.invacare.com
Please have your model number and purchase date available to
complete your registration.
Any registration information you submit will only be used by
Invacare Corporation and protected as required by applicable laws
and regulations.
FEATURES
Stratos™Portable Plus 8 Part No 1150755
FEATURES
Inlet Air Filter
AC/DC Power
Outlet
On/Off Button
Compressor
Outlet
TYPICAL PRODUCT PARAMETERS
Part No 1150755 9 Stratos™Portable Plus
TYPICAL PRODUCT PARAMETERS
NOTE:*Weightiswithoutnebulizerandtubing.
SOUND LEVEL: 58 dBA
OPERATING
TEMPERATURE RANGE:
50°F - 104°F (10°C to 40°C); 10 to 95% RH
FOAM INTAKE FILTER: Expanded Polyurethane
SAFETY SYSTEMS: High temperature compressor shutdown.
REGULATORY LISTING: In compliance with EN 60601-1
DIMENSIONS
WITHOUT BATTERY:
WITH BATTERY:
5.1 x 3.6 x 1.6 inches (13cm x 9cm x 4cm)
5.1 x 3.6 x 2.6 inches (13cm x 9cm x 7cm)
*WEIGHT
WITHOUT BATTERY:
WITH BATTERY:
1 lbs (450 g)
1.4 lbs (650 g)
POWER SUPPLY: 100-120 VAC 50-60 Hz, 12 VDC, 1.4 A
MAXIMUM PRESSURE: 29 psi (200 kPa)
MAXIMUM FLOW RATE: 10 L/min
STORAGE CONDITIONS: -13°F to 158°F (-25° to 70°C); 10 to 95%
RH
OPERATING FLOW
RATE:
3.5 L/min @ 14.5 PSI operating pressure
MODE OF OPERATION: Intermittent Use 30 min ON/30 min OFF
SUPPLEMENTAL INFORMATION
Stratos™Portable Plus 10 Part No 1150755
SUPPLEMENTAL
INFORMATION
Compressor
Iftheunitshutsdownfrequentlyorfailstostart,youmay
havealowvoltagesituation.
Lowvoltagecanalsobesuspectedwhen:
•Thecompressorfailstostartormotordoesnotgetupto
fullpowerorspeed.
•Othermotoroperatedappliancesfailtooperateproperly
ortoomanymotoroperatedappliancesareonsame
circuit.
Extension Cords
Makecertainextensioncordisingoodcondition.Make
certainextensioncordwireisNOTLESSthan18gaugefor25
feet.
HANDLING
Part No 1150755 11 Stratos™Portable Plus
HANDLING
Shipping Instructions
Theshippingcontainerhasbeendesignedtoassure
protectionofthisdevice.
Ifthisdeviceistobereshippedbycommoncarrier,itshould
bepackedinthesamecarton.
Unpacking
1. Checkforanyobviousdamagetothecartonorits
contents.Ifdamageisevident,DONOTuse.Notify
carrier/InvacareoryourlocalInvacaredealer.
2. Removealltheloosepackingfromthecarton.
3. Carefullyremoveallthecomponentsfromthecarton.
NOTE:Retaincartonandpackingmaterialsforuseinshippingor
storingtheunituntiluseisrequired.
Inspection
1. Examineexteriorfornicks,dents,scratchesorother
damage.Inspectallcomponents.
SECTION 1—IMPORTANT SAFEGUARDS
Stratos™Portable Plus 12 Part No 1150755
SECTION 1—IMPORTANT
SAFEGUARDS
WARNING
SECTION 1 - IMPORTANT SAFEGUARDS contains
important information for the safe operation and use of
this product.
CAUTION
“Caution:Federallawrestrictsthisdevicetosaleorrentalby
oronorderofaphysician,oranyotherpractitionerlicensed
bythelawoftheStateinwhichhe/shepracticestouseor
ordertheuseofthisdevice.”
Whenusingelectricalproducts,especiallywhenchildrenare
present,basicsafetyprecautionsshouldALWAYSbe
followed,includingthefollowing.
READALLINSTRUCTIONSBEFOREUSING
SECTION 1—IMPORTANT SAFEGUARDS
Part No 1150755 13 Stratos™Portable Plus
DANGER
Riskofelectricshock.DONOTdisassemble.Referservicing
toqualifiedservicepersonnel.
FIRERISK‐DONOTusethisproductinanoxygenenriched
environment(i.eoxygentent).
To Reduce the Risk of Electrocution:
ALWAYSunplugthisproductIMMEDIATELYafterusing.
DONOTusewhilebathing.
DONOTplaceorstoreproductwhereitcanfallorbepulled
intoatuborsink.
DONOTreachforproductthathasfallenintowater .Unplug
IMMEDIATELY.
DONOTplaceinordropintowaterorotherliquid.
DONOTreachforaproductthathasfallenintowater.
UnplugIMMEDIATELY.
SECTION 1—IMPORTANT SAFEGUARDS
Stratos™Portable Plus 14 Part No 1150755
WARNING
To Reduce the Risk of Burns,
Electrocution, Fire and Injury to Persons:
ThisproductshouldNEVERbeleftunattendedwhen
pluggedin.
Closesupervisionisnecessarywhenthisproductisusedby,
on,ornearchildrenandphysicallychallengedindividuals.
Usethisproductonlyforitsintendeduseasdescribedinthis
manualandonlywiththeprescribedmedication.Usethis
productonlyunderphysician’sdirection.
NEVERoperatethisproductwithadamagedcordorplug,if
itisnotworkingproperly,ifitwasdroppedordamaged,orif
itwasdroppedintowater.Callqualifiedservicepersonnelfor
examinationandrepair.
Keepthenebulizertubing,systempowercord,andunitaway
fromheatedorhotsurfaces,includingspaceheaters,electric
blankets,stovesandsimilarelectricalappliances.
NEVERdroporinsertobjectsintoanyopeningorhose.
NEVERusewhilesleepingordrowsy.
SECTION 1—IMPORTANT SAFEGUARDS
Part No 1150755 15 Stratos™Portable Plus
WARNING
NEVERblocktheairopeningsoftheproductorplaceitona
softsurface,suchasabedorcouch,wheretheairopenings
maybeblocked.Keeptheairopeningsfreefromlint,hairand
thelike.Blockedopeningsmaycausetheunittoshutdown.
ContactdealerIMMEDIATELY.
TheStratosPortablePlusCompressorNebulizerSystemuses
thesurroundingairtoeffectivelyadministertheprescribed
medicationthroughthenebulizer.Theuserandadministrator
shouldbeawareofsurroundingssoasnottohave
contaminatedairfilteredthroughthecompressornebulizer
system.(Examplescanbeaircontaminatedwithpaintor
cleaningfumes,weedkiller,carexhaust,smoking,etc.)
DONOTusetheStratosPortable PlusCompressorNebulizer
Systemintheseenvironments.Otherwise,seriousbodily
injurymayoccur.
Thisunitisoilless.DONOTlubricate.
ThisequipmentisNOTsuitableforuseinthepresenceofa
flammableanestheticmixturewithairorwithnitrousoxide.
DONOToperatethecompressorwhileitisstillinthe
carryingcase.
SECTION 1—IMPORTANT SAFEGUARDS
Stratos™Portable Plus 16 Part No 1150755
WARNING
Whennotadministeringtreatment,keepoutofthereachof
smallchildren.Someofthepartsofthenebulizersystemare
smallenoughforchildrentoswallow.Thetubingmay
presentastrangulationhazard
NEVERtouchtheunitwithwethands.
DONOTpullonthepowercordtounplugtheunitfroman
electricaloutlet.
DONOToverloadwalloutlets.
PumpmaintenanceMUSTbeperformedbyaqualified
servicetechnician.
SAVE THESE INSTRUCTIONS
SECTION 2—OPERATING INSTRUCTIONS
Part No 1150755 17 Stratos™Portable Plus
SECTION 2—OPERATING
INSTRUCTIONS
WARNING
Remove the compressor from the carrying case before
use.
DO NOT operate unit without filter.
Avoid operating this product in a dusty environment.
Otherwise, premature compressor wear could occur.
Setup
NOTE:Forthisprocedure,refertoFIGURE2.1onpage 18.
1. Washyourhandsbeforeyoubeginthetreatment
procedure.
2. Placethedeviceonatablesothatthecontrolscanbe
reachedwhenseated.
3. Openthenebulizerbyrotatingthetopclockwisewhile
securelyholdingthebottom.
4. Makesuretheconeiscorrectlypositionedinthecup.
SECTION 2—OPERATING INSTRUCTIONS
Stratos™Portable Plus 18 Part No 1150755
WARNING
DO NOT exceed the maximum allowed quantity of six ml
of medication. The maximum capacity of the nebulizer
medication cup is 6 ml.
CAUTION
NEVER pour medication into the compressor outlet.
Damage to the compressor will occur.
5. Addtheprescribed
amountofmedicationto
thecupofthenebulizer
usinganeyedropper,
premeasureddoseor
ampoule(FIGURE2.1).
6. Closethenebulizer.
FIGURE 2.1 Adding
Medication
7. Attachoneendofthetubingontothecompressoroutlet
andconnecttheotherendtothenebulizer.
8. Inhighhumidityconditions,moistureorcondensation
canoccurinthetubing.Ifthishappens,simplyturnonthe
compressorwiththetubingattachedandrunfor2‐3
minutesorhangthetubingsothemoisturecandrainout.
9. Connectthemouthpiecetothetopsectionofthenebulizer
(ifrequired).
Eyedropper
Nebulizer
Cup
SECTION 2—OPERATING INSTRUCTIONS
Part No 1150755 19 Stratos™Portable Plus
10. Tousewithbattery,chargefor6hours.Referto
ConditioningtheBatteryonpage 23.
11. TousethenebulizersystemwiththeACpowercord,
connectthepowercordplugintothepoweroutletonthe
sideofthenebulizercompressorsystem.Connectthe
powercordtotheACadapterandinserttheplugfromthe
ACadapterintotheelectricaloutlet.
12. TousethenebulizersystemwiththeDCautoadapter,
connecttheDCautoadaptertothepoweroutletonthe
sideofthenebulizercompressorsystem.Connecttheauto
adapterplugoftheDCcordtotheautoadapterreceptacle.
DANGER
To avoid the risk of possible electrical shock, the nebulizer
system MUST be operated on the specified power source.
Treatment Instructions
NOTE:Forthisprocedure,refertoFIGURE2.2onpage20.
NOTE:TheInvacareStratosPortablePlusNebulizerSystemhas
beendesignedforintermittentuse.Normaltreatmenttimeshouldbe
fivetotenminutes.Turnoffthenebulizersystemafter30minutes
ofuseandallowthedevicetocooldown30minutesbeforeturning
itonagain.
SECTION 2—OPERATING INSTRUCTIONS
Stratos™Portable Plus 20 Part No 1150755
1. Sitinarelaxedanduprightposition.
2. TurnonthedevicebypushingtheOn/Offbutton.
3. Begintreatmentby
placingthenebulizer
mouthpiecebetween
yourteethandcloseyour
mouth.Inhaledeeplyand
slowlyastheaerosol
beginstoflowandthen
exhaleslowly.
4. Whentreatmentis
completed,turnoffthe
nebulizersystemand
unplugthepower
adapter.
FIGURE 2.2 Using the
Nebulizer
5. Removethemouthpiecefromthenebulizer.
6. Removethenebulizerandfollowthecleaning
instructions.RefertoCleaningandDisinfectingon
page 27.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Invacare Stratos Aerosol IRC1730 User manual

Category
Air compressors
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI