5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Pass-Thru Humidity
Hot Cabinet
FL-2255
Rev. 13 (6/08) Page 2 of 6
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137PWSUA...C & H138PWS1834C
Pass-Through Humidity Series Hot Cabinets
HOW TO HOLD WITH HUMIDITY:
Fill water pan with HOT water.
Push “POWER” switch to “ON.”
Turn the “AIR” Thermostat to No. 9.
Turn the “HUMIDITY” thermostat to No. 9.
Preheat for 45 minutes.
Turn “AIR” thermostat to desired temperature.
(See thermostat settings below.)
Put product into cabinet.
1.
2.
3.
4.
5.
6.
7.
NOTES: 180°F/82°C is approximately No. 8. Proper food holding temperature is 140°F/60°C or higher.
HOW TO HOLD:
No water is needed in pan.
Push power switch to “ON.”
Yellow light will come on.
Turn “AIR” thermostat to No. 9.
Preheat cabinet for 45 minutes.
Turn “AIR” thermostat to desired temperature.
(See thermostat settings below.)
Put product into cabinet.
1.
2.
3.
4.
5.
6.
7.
SOME TYPICAL THERMOSTAT SETTINGS:
Thermostat Setting Result Thermostat Setting Result
Air Humidity Cab. Temp. Humidity Air Humidity Cab. Temp Humidity
150° F Off 150° F N/A Low Hold Med 160°F 50%
Med Hold Off 175° F N/A Low Hold High 160°F 95%
High Hold Off 205° F N/A Med Hold Low 170°F 15%
Maximum Off 220° F N/A Med Hold Med 170°F 35%
Med Hold High 170°F 85%
Proof 3½ 100°F 98% Med Hold Max 170°F 90%
Low Low 115° F 98% High Hold Low 205°F 7%
Low Med 150° F 95% High Hold Med 205°F 15%
Low High 150° F 95% High Hold High 205°F 40%
Low Hold Low 160° F 30% Maximum Maximum 220°F 30%
Note: These settings are based on laboratory conditions and may differ from conditions at point of use.
Experiment with the settings to determine what is best for your application.
Air is VERY HOT when door is opened.
WARNING