Ives 7259 is a bottom center pivot clamp designed for doors with a minimum thickness of 2 inches. It allows for easy installation of a pivot set into the bottom of a door and the floor, providing a smooth and secure pivot action. The adjustable pivot point and removable heel section make it suitable for various door configurations and clearance requirements. The included mounting screws and Allen wrench ensure a secure and precise installation. Whether you're a professional or a DIY enthusiast, the Ives 7259 offers a reliable solution for your pivot door needs.

Ives 7259 is a bottom center pivot clamp designed for doors with a minimum thickness of 2 inches. It allows for easy installation of a pivot set into the bottom of a door and the floor, providing a smooth and secure pivot action. The adjustable pivot point and removable heel section make it suitable for various door configurations and clearance requirements. The included mounting screws and Allen wrench ensure a secure and precise installation. Whether you're a professional or a DIY enthusiast, the Ives 7259 offers a reliable solution for your pivot door needs.

7259
Bottom Center Pivot
Improper pivot set installation can lead to personal injury or property damage. Follow
all instructions carefully. For questions contact Technical Support at 1-888-371-7331.
CAUTION
!
1. Prepare and mortise bottom of door and floor to receive pivot set. Determine pivot location using
dimensions on reverse side. Be sure to properly locate base plate. The finish plate of pivot base
assembly should be removed until installation is complete.
2. Prepare bottom of door. If bottom of door has not been prepared prior to pivot installation, mortise per
dimensions on reverse side. The bottom of the door must have a removable heel section (Figure 1).
3. Remove pivot clamp from door pivot leaf with 5/16” Allen wrench. Locate, drill, and tap mounting holes
for door leaf. Mount door leaf in bottom of door with screws provided.
4. Locate and prepare cutout in floor for pivot base. The pivot base assembly must be located so that the
center line of top pivot point is plumb with center line of base pivot point. Secure pivot base:
A. Prepare compound that will be used to fill around pivot base (concrete, cement, grout, etc.).
B. Fill cutout with compound, leaving room for concrete channel base to fit flush with floor.
C. Set pivot base into cutout. Align base assembly so pivot point is in proper position.
D. Use a level to be sure pivot base assembly is level on all sides.
E. Secure in proper position until compound sets up completely. Once compound has set up, mounting
screws can be removed, allowing removal or replacement of pivot base assembly.
F. Re-attach finish plate.
5. Maneuver door into position, about 90° to frame. Position door so door pivot leaf mates with pivot pin
as shown in Figure 2. Re-attach pivot clamp as shown in Figure 3. Do not tighten clamp screws
completely. Engage pivot leafs at top of door. Now tighten clamp screws securely.
6. If height adjustment is necessary for proper clearance, use shims between door bottom and pivot
leaf to increase clearance. To decrease clearance, mortise in door must be made deeper.
Clamp
screws
Pivot clamp
Finish
screws
Finish plate
Mounting
screws
Concrete
anchor pins
2” minimum door thickness.
NOTE
!
Figure 1 Figure 2 Figure 3
Door
leaf
Base
plate
Pivot
pin
Concrete
channel base
Installation Instructions
26633 Rev. 4 © 2006 Ingersoll-Rand Company Limited
26633 Rev. 4
It is very important for installer to verify that center line of top pivot point lines up
with center line of bottom pivot point before final installation.
NOTE
!
End View
with Threshold
End View
without Threshold
**
Top View
C pivot
L
Radius of heel
edge of door must
not exceed pivot
point to jamb
distance
5-1/8”, 130 mm
1/16”
2 mm
5”, 127 mm
4-13/16”, 122 mm
3/8”
10 mm
1-7/8”
48 mm
2-5/16”
59 mm
to
1-5/8”
41 mm
2-3/4”
70 mm
Removable door
section to allow
access to pivot leaf
bracket screws
2-1/2”
64 mm
C pivot
and door
L
13/16”
21 mm
*
5-1/16”, 129 mm
**
Pivot center may
be varied as
needed; standard
distance is 2-3/4”
as shown.
*
Dimensions for cement case
cutout. Depth is 3/8” without
threshold, 5/16” with threshold.
**
26633-00
  • Page 1 1
  • Page 2 2

Ives 7259 User manual

Type
User manual

Ives 7259 is a bottom center pivot clamp designed for doors with a minimum thickness of 2 inches. It allows for easy installation of a pivot set into the bottom of a door and the floor, providing a smooth and secure pivot action. The adjustable pivot point and removable heel section make it suitable for various door configurations and clearance requirements. The included mounting screws and Allen wrench ensure a secure and precise installation. Whether you're a professional or a DIY enthusiast, the Ives 7259 offers a reliable solution for your pivot door needs.