Form I-VR-RC, P/N 205763R2, page 1
Applies to: Model VR
Reector End Covers, Option CD27
Form I-VR-RC (Version A)
(Obsoletes Form I-VR-RC)
The optional end covers are designed to “close” the vertical space on both the com-
bustion chamber end and the exhaust heat exchanger end of the reector length. End
covers may be attached before the reectors are installed or may be added to an exist-
ing installation.
Description and
Kit Components
Installation
Instructions
Components

IMPORTANT: If the
optional reector
end covers are being
added to a system that
is already installed,
turn off the gas and
the electrical power.
Allow the system to
cool before installing
reector end covers.
1. Position the reector end cover over the end of the reector that will cover the
combustion chamber tube. (See FIGURE 2.) Using the end cover as a template,
mark the hole locations on the reector.
2. Remove the end cover and carefully drill four 7/32” holes in the reector.
3. Re-position the end cover and fasten to the reector with four screws and nuts
from the option package.
4. Repeat the process to install the cover at the exhaust end of the reector.
If the system is already installed, turn on the gas and the electric and check for proper
operation. If the system is being installed, continue with the instructions in the heater
installation manual.
(800) 695-1901, www.ReznorHVAC.com
©2014 Reznor, LLC. All rights reserved.
Trademark Note: Reznor
®
is registered in at least the United States.
0614 Form I-VR-RC (Version A.1)
FIGURE 1 - Reector
End Cover, P/N 268218








WARNING
The kit is to be installed by a qualied service person in accordance with
these instructions and in compliance with all codes and requirements
of authorities having jurisdiction. The qualied agency performing this
work assumes responsibility for this installation.
Option Designation CD27
Option Package P/N 205762
Description Qty P/N
Reector End Cover 2 268218
Screw #10-32 x 1/2" long 8 113275
Nut #10-32 Keps 8 26490
FIGURE 2 - Installation
of a Reector End Cover
/