UNITED STATES STOVE COMPANY • 227 INDUSTRIAL PARK ROAD • SOUTH PITTSBURG, TENNESSEE 37380 • WWW.USSTOVE.COM
For Customer Service: PHONE: (800) 750-2723 FAX: (423) 837-2109 Email: [email protected]
Part No.: 851740 rev H
UNITED STATES STOVE COMPANY
“Keeping North America Warm Since 1869”
C
S
S
U
C
O
M
P
A
N
Y
U
N
I
T
E
D
S
T
A
T
E
S
S
T
O
V
E
Models: 5824
This Pellet heater has been safety tested and listed for use in the USA and Canada
It is also certified and meets EPA Phase II requirements.
Owner’s Manual
Please read this entire manual before installation and use of this pellet fuel-burning room heater.
Failure to follow these instructions could result in property damage, bodily injury, or even death.
Contact your local building or re ofcials about obtaining permits, restrictions and installation
inspection requirements in your area.
Save these instructions.





Safety Tested to:
ASTM E 1509-04, ULC-S627-00 and ULC/ORD-C1482-M1990
2 USSC




HeatingSpecications.................................................................................................6
Dimensions..................................................................................................................6
ElectricalSpecications...................................................................................6
FuelConsiderations.........................................................................................6
SafetyandEPACompliance............................................................................6

InstallationOptions..........................................................................................7
FloorProtection...............................................................................................7
Clearances......................................................................................................8
VentingRequirements.....................................................................................9
MaximumVentingDistance.............................................................................9
PelletVentType...............................................................................................9
PelletVentInstallation.....................................................................................9
PelletVentTermination....................................................................................9
VentTerminationClearances.........................................................................10
ThroughtheWallInstallation......................................................................... 11
ThroughtheRoof/CeilingInstallation............................................................. 11
OutsideAirSupply.........................................................................................12
SpecialMobileHomeRequirements.............................................................12


Start-UpProcedure........................................................................................14
ShutDownProcedure....................................................................................14
DailyOperation..............................................................................................15
SafetyandConvenienceFeatures................................................................15

ExhaustSystem.............................................................................................15
InteriorChambers..........................................................................................16
AshDisposal..................................................................................................16
CheckandCleantheHopper........................................................................16
MainDoorGaskets........................................................................................16
BlowerMotors................................................................................................16
PaintedSurfaces...........................................................................................16
Glass..............................................................................................................16
FallStart-Up...................................................................................................16
SpringShutDown..........................................................................................16
YearlyServicing.............................................................................................16



Table of Contents
USSC 3
" CUTHERE " CUTHERE
WARRANTY INFORMATION CARD




q q q q q




q q
q q q



q

q

q

  
Please attach a copy of your purchase receipt.
Warranty not valid without a Proof of Purchase.
Warranty information must be received within 30 days of original purchase.
Detach this page from this manual, fold in half with this page to the inside and tape
together. Apply a stamp and mail to the address provided. You may use an enve-
lope if you choose.
You may register online by going to www.usstove.com
All information submitted will be kept strictly condential. Information provided will not be sold for advertising purposes.
Contact information will be used solely for the purpose of product notications.
4 USSC
" CUTHERE " CUTHERE
Ê É
 







USSC 5
IMPORTANT:Readthisentiremanualbeforeinstalling
and operating this product. Failure to do so may
resultinpropertydamage,bodilyinjury,orevendeath.
Properinstallationofthisheateriscrucialforsafeand
efcientoperation.
Install vent at clearances specified by the vent
manufacturer.
Donotconnectthepelletventtoaventservingany
otherapplianceorheater.
Donot install auedamperin the exhaustventing
systemofthisunit.
Useofoutsideairisnotrequiredforthisunit.
Contact your local building officials to obtain a
permitandinformationonanyadditionalinstallation
restrictionsorinspectionrequirementsinyourarea.
Do not throw this manual away. This manual has
important operating and maintenance instructions
thatyouwillneedatalatertime.Alwaysfollowthe
instructionsinthismanual.
Thisheater isdesigned and approved for premium
hardwoodpelletfuelonly.Anyothertypeoffuelburned
inthisheaterwillvoidthewarrantyandsafetylisting.
Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter uid,orsimilarliquids to
startor’freshenup’areinthisheater.Keepallsuch
liquidswellawayfromtheheaterwhileitisinuse.
Aworkingsmokedetectormustbeinstalledinthesame
roomasthisproduct.
Donotunplugtheheaterifyoususpectamalfunction.
TurntheheaterOFFbypressing andcontactyour
dealer.

Yourheaterrequiresperiodicmaintenanceandcleaning
(see MAINTENANCE ). Failure to maintain your
heatermayleadtoimproperand/orunsafeoperation.
Disconnect the power cord before performing any
maintenance!NOTE:Pressing toswitchtheunit
”OFF”doesnotdisconnectallpowertotheelectrical
componentsoftheheater.
Nevertrytorepairorreplaceanypartoftheheaterun-
lessinstructionsfordoingsoaregiveninthismanual.
Allotherworkshouldbedonebyatrainedtechnician.
Do not operate your heater with the viewing door
open. The auger will not feed pellets under these
circumstancesandasafetyconcernmayarisefrom
sparksorfumesenteringtheroom.
Allow the heater to cool before performing any
maintenanceorcleaning.Ashesmust bedisposed
inametalcontainerwithatightttinglid.Theclosed
container of ashes should be placed on a non-
combustiblesurfaceorontheground,wellawayfrom
allcombustiblematerials,pendingnaldisposal.
SootandFlyash: FormationandNeedforRemoval
- The products of combustion will contain small
particlesofyash.Theyashwillcollectintheexhaust
ventingsystemandrestricttheowoftheuegases.
Incompletecombustion,suchasoccursduringstartup,
shutdown,orincorrectoperationoftheroomheaterwill
leadtosomesootformationwhichwillcollectinthe
exhaustventingsystem.Theexhaustventingsystem
shouldbeinspectedatleastonceamonthduringthe
heatingseasontodetermineifcleaningisnecessary.
Theexhaustsystemshouldbecheckedmonthlyduring
theburningseasonforanybuild-upofsootorcreosote.
Donottouchthehotsurfacesoftheheater.Educateall
childrenonthedangersofahigh-temperatureheater.
Youngchildrenshouldbesupervisedwhentheyare
inthesameroomastheheater.
Thehopperandheatertopwillbehotduringoperation;
therefore,youshouldalwaysusesometypeofhand
protectionwhenrefuelingyourheater.
      This unit
mustbepluggedintoa110-120V,60Hzgrounded
electricaloutlet.Donotuseanadapterplugorsever
thegroundingplug.Donot routetheelectricalcord
underneath,infrontof,orovertheheater.Donotroute
thecordinfoottrafcareasorpinchthecordunder
furniture.
Theheaterwillnotoperateduringapoweroutage.Ifa
poweroutagedoesoccur,checktheheaterforsmoke
spillageandopenawindowifanysmokespillsintothe
room.
Theviewingdoormustbeclosedandsealedduring
operation.Keepsealingoodcondition.
Neverblockfreeairowthroughtheopenventsofthe
unit.
 Never add additional pellets to the burn pot as a
dangerousover-reconditionmayresult.
Keepforeignobjectsoutofthehopper.
Themovingpartsofthisheaterarepropelledbyhigh
torqueelectricmotors.Keepallbodypartsawayfrom
theaugerwhiletheheaterispluggedintoanelectrical
outlet.Thesemovingpartsmaybegintomoveatany
timewhiletheheaterispluggedin.
Donotplaceclothingorotherammableitemsonor
nearthisheater.
When installed in a mobile home, the heater must
begroundeddirectlytothesteelchassisandbolted
to the oor. WARNING—THIS UNIT MUST NOT
BE INSTALLED IN THE BEDROOM (per HUD
requirements). CAUTIONTHE STRUCTURAL
INTEGRITYOFTHEMOBILEHOMEFLOOR,WALL,
ANDCEILING/ROOFMUSTBEMAINTAINED.
Thisapplianceisnotintendedforcommercialuse.
*Thisapplianceisafreestandingheater.Itisnotintendedtobeattachedtoanytypeofducting.Itisnotafurnace.
Safety Precautions
6 USSC

Height 33-1/2in.(851mm)
Width 18-1/4in.(464mm)
Depth 19-1/4in.(489mm)

*Pelletsizemayeffecttheactualrateoffuelfeedandburntimes.Fuelfeedratesmayvarybyasmuchas20%.UsePFIlistedfuelforbestresults.
ElectricalRating 110-120volts,60HZ,4.5Amps
Watts(maximum) 520(approx.)


YourPellet heater is designedtoburnpremiumhardwoodpelletsthatcomplywithAssociationofPelletFuelIndustries
standards.(Minimumof40lbsdensitypercubicft,1/4”to5/16”diameter,lengthnogreaterthan1.5”,notlessthan8,200
BTU/lb,moistureunder8%byweight,ashunder1%byweight,andsaltunder300partspermillion).Pelletsthatare
soft,thatcontainexcessiveamountsofloosesawdust,orthathavebeenorarewetwillresultinreducedperformance.
Duetothedifferentfueldensitiesandsizes,thefuelfeedratemayvary.Thismayrequireanadjustmenttotheslider
dampersettingortheaugerfeedtrimsettingonlow.
Storeyourpelletsinadryplace.DONOTstorethefuelwithintheinstallationclearancesoftheunitorwithinthespace
requiredforrefuelingandashremoval.Doingsocouldresultinahousere.

YourPelletheater hasbeensafetytestedandlistedtoASTME1509-04,ULC/ORDC1482-1990,andULC-S627-00
byOMNI-TestLaboratories,Inc.Portland,Oregon,USA.ItisalsocertiedandtestedtoEPAPhaseIIrequirements.
MInimumFuelBurnRate* 1.75lbs./hr.±5%
BurnTime(lowestsetting)* 23hrs.±5%
HopperCapacity 40lbs.
Specications
USSC 7

 


A—Placedon anon-combustibleoorsurfacein compliancewithclearancerequirementsfora
freestandingheaterinstallation.
An—Placedonanon-combustibleoorsurfaceincompliancewithclearancerequirementsforanalcove
installation.
Your heater may be installed to code in either a  or   (see SPECIAL MOBILE HOME
REQUIREMENTS).ApprovedforU.S.installationONLY.
Itisrecommendedthatonlyaauthorizedtechnicianinstallyourheater,preferablyanNFIcertiedspecialist.
DONOTCONNECTTHISUNITTOANYAIRDISTRIBUTIONDUCTORSYSTEM.
Themanufacturerwillnotbeheldresponsiblefordamagecausedbythemal-
functionofaheaterduetoimproperventingorinstallation.Call(800)750-2723and/orconsultaprofessional
installerifyouhaveanyquestions.

Thisunitmustbeinstalledonanon-combustibleoorsurface.Ifaoorpadisused,itshouldbeULlistedorequal.
Theoorpadornon-combustiblesurfaceshouldbelargeenoughtoextendaminimumof6-inchesinfront,6-incheson
eachside,and1-inchbehindtheheater(seeFIGURE1).
Floorprotectionmustextendunderand2-inchestoeachsideofthechimneyteeforaninteriorverticalinstallation(see
FIGURE2).Onlyanelbowtypeconnectioncanbeusedforindoorinstallation.
Yourheaterwillneedaminimum28”(711mm)x31”(787mm)oorprotector.
AFloorProtectorof1inchthickisrecommendedforthisinstallation.
Installation
8 USSC

Yourheaterhasbeentestedandlistedforinstallationinresidential,mobilehome,andalcoveapplicationsinaccordance
withtheclearancesgiveninFIGURES3-4andTABLE1.
NOTE: Distance “D” on the left-hand side of your heater may need to be greater than the minimum required
clearance for suitable access to the control panel.

SIDEWALL/CORNER
MINIMUMCLEARANCES

MINIMUMALCOVECLEARANCES
PARALLEL A-Backwalltoheater 8.00”/203mm
B-Backwalltoue 1.00”/25mm
C-Sidewalltoue 7.50”/191mm
D-Sidewalltoedgeofunit 4.00”/100mm
CORNER E-Adjacentwalltounit 2.00”/50mm
ALCOVE F-Alcovedepth 25.00”/635mm
G-AlcoveHeight 47.00”/1194mm
AlcoveWidth 26.50”/673mm

MINIMUMCLEARANCES
(inches/mm)
Installation
USSC 9

 
 
 
Thefollowinginstallationguidelinesmustbefollowedtoensureconformitywithboththesafetylistingofthisheaterand
tolocalbuildingcodes.Donotusemakeshiftmethodsorcompromiseintheinstallation.
Thisunitisequippedwithanegativedraftsystemthatpullsairthroughtheburnpotand
pushestheexhaustoutofthedwelling.Ifthisunitisconnectedtoauesystemotherthanthewayexplained
inthismanual,itwillnotfunctionproperly.

InstallationMUSTincludeatleast3ft(0.91m)ofverticalpipeoutsidethehome.Thiswillcreatesomenaturaldraftto
reducethepossibilityofsmokeorodorduringapplianceshutdownandkeepexhaustfromcausinganuisanceorhazard
byexposingpeopleorshrubstohightemperatures.Themaximumrecommendverticalventingheightis12ft(3.66m)for
3-inchtype“PL”vent.TotallengthofhorizontalventMUSTNOTexceed4ft(1.22m).Thiscouldcausebackpressure.
Usenomorethan180degreesofelbows(two90-degreeelbows,ortwo45-degreeandone90-degreeelbow,etc.)to
maintainadequatedraft.

AULlisted3-inchor4-inchtype“PL”pelletventexhaustsystemmustbeusedforinstallationandattachedtothepipe
connectorprovidedonthebackoftheheater(usea3-inchto4-inchadapterfor4-inchpipe).Connectionatbackof
heatermustbesealedusingHi-TempRTV.Use4-inchventiftheventheightisover12ft(3.66m)oriftheinstallation
isover2,500feetabovesealevel.
WerecommendtheuseofSimpsonDura-Vent
®
orMetal-Fab
®
pipe(ifyouuseotherpipe,consultyourlocalbuilding
codesand/orbuildinginspectors).DonotuseType-BGasVentpipeorgalvanizedpipewiththisunit.Thepelletvent
pipeisdesignedtodisassembleforcleaningandshouldbecheckedseveraltimesduringtheburningseason.Pellet
ventpipeisnotfurnishedwiththeunitandmustbepurchasedseparately.

Theinstallationmustincludeaclean-outteetoenablecollectionofyashandtopermitperiodiccleaningoftheexhaust
system.90-degreeelbowsaccumulateyashandsoottherebyreducingexhaustowandperformanceoftheheater.
Eachelboworteereducesdraftpotentialby30%to50%.
Alljointsintheventsystemmustbefastenedbyatleast3screws,andalljointsmustbesealedwithHi-TempRTV
siliconesealanttobeairtight.Theareawheretheventpipepenetratestotheexteriorofthehomemustbesealedwith
siliconeorothermeanstomaintainthevaporbarrierbetweentheexteriorandtheinteriorofthehome.
Ventsurfacescangethotenoughtocauseburnsiftouchedbychildren.Noncombustibleshieldingorguardsmaybe
required.
Onlyanelbowtypeconnectioncanbeusedforindoorinstallation.
Thechimneyconnectorshallnotpassthroughanatticorroofspace,closetorsimilarconcealedspace,oraoor,orceiling.

Donotterminatetheventinanenclosedorsemi-enclosedarea,suchas;carport,garage,attic,crawlspace,undera
sundeckorporch,narrowwalkway,oranyotherlocationthatcanbuildupaconcentrationoffumes.
Theterminationmustexhaustabovetheoutsideairinletelevation.
Theterminationmustnotbelocatedwhereitwillbecomepluggedbysnoworothermaterials.

Installation
10 USSC

A) Minimum4-foot(1.22m)clearancebeloworbesideanydoororwindowthatopens.
B) Minimum1-foot(0.3m)clearanceaboveanydoororwindowthatopens.
C) Minimum3-foot(0.91m)clearancefromanyadjacentbuilding.
D) Minimum7-foot(2.13m)clearancefromanygradewhenadjacenttopublicwalkways.
E) Minimum2-foot(0.61m)clearanceaboveanygrass,plants,orothercombustiblematerials.
F) Minimum3-foot(0.91m)clearancefromanforcedairintakeofanyappliance.
G)Minimum2-foot(0.61m)clearancebelowevesoroverhang.
H) Minimum1-foot(0.3m)clearancehorizontallyfromcombustiblewall.
I) Mustbeaminimumof3foot(0.91m)abovetheroofand2foot(0.61m)abovethehighestpointortheroofwithin
10feet(3.05m).
G

VENTTERMINATIONCLEARANCES
Installation
USSC 11
(RECOMMENDEDINSTALLATION)
CanadianinstallationsmustconformtoCAN/CSA-B365.
Toventtheunitthroughthewall,connectthepipeadapter
totheexhaustmotoradapter.Iftheexhaustadapterisat
least18in.(457mm)abovegroundlevel,astraightsection
ofpelletventpipecanbeusedthroughthewall.
Your heater dealer should be able to provide you with
akitthat willhandle most ofthis installation,whichwill
includeawallthimblethatwillallowtheproperclearance
throughacombustible wall.Onceoutsidethestructure,
a3in.(76mm)clearanceshouldbemaintainedfromthe
outsidewallandacleanoutteeshouldbeplacedonthe
pipewitha90-degreeturnawayfromthehouse.Atthis
point,a3ft(0.91m)(minimum)sectionofpipeshouldbe
addedwithahorizontalcap, whichwould completethe
installation(seeFIGURE6).
A support bracket should be placed just below the
termination cap or one every 4ft (1.22m) to make the
systemmorestable.Ifyouliveinanareathathasheavy
snowfall,itisrecommendedthattheinstallationbetaller
than3ft(0.91m)togetabovethesnowdriftline.Thissame
installationcanbeusedifyourheaterisbelowgroundlevel
bysimplyaddingtheclean-outsectionandverticalpipe
insideuntilgroundlevelisreached.Withthisinstallation
youhavetobeawareofthesnowdriftline,deadgrass,and
leaves.Werecommenda3ft(0.91m)minimumvertical
riseontheinsideoroutsideofthehouse.
The“throughthewall”installationistheleastexpensiveandsimplestinstallation.Neverterminatetheendventundera
deck,inanalcove,underawindow,orbetweentwowindows.WerecommendSimpsonDura-Vent
®
orMetal-Fab
®
kits.

Whenventingtheheaterthroughtheceiling,thepipeisconnectedthesameasthroughthewall,excepttheclean-out
teeisalwaysontheinsideofthehouse,anda3in.(76mm)adapterisaddedbeforetheclean-outtee.
Youmustusetheproperceilingsupportangesandroofashing(suppliedbythepipemanufacturer;followthepipe
manufacturer’sdirections).Itisimportanttonotethatifyourverticalrunofpipeismorethan15ft(4.57m),thepellet
ventpipesizeshouldbeincreasedto4in.(102mm)indiameter.
Donotexceedmorethan4ft(1.22m)ofpipeonahorizontalrunanduseasfewelbowsaspossible.Ifanoffsetis
required,itisbettertoinstall45-degreeelbowsratherthan90-degreeelbows.

TYPICALTHROUGHTHEWALLINSTALLATION
Installation
12 USSC
(optional,unlessinstallinginamobilehome)
Dependingonyourlocationandhomeconstruction,outsideairmaybenecessaryforoptimalperformance.
Metalpipe(solidorexible)mustbeusedfortheoutsideairinstallation.PVCpipeisNOTapprovedandshouldNEVER
beused.
Awindshieldovertheterminationoftheoutsideairpipeora90-degreeelboworbendawayfromtheprevailingwinds
MUSTbeusedwhenanoutsideairpipeisinstalledthroughthesideofabuilding.TheoutsideairterminationMUST
beatleast1ft(0.305m)awayfromtheexhaustsystemtermination.
Theoutsideairpipeonyour heateris2”(50.8mm)OD.Theoutsideairconnectingpipemustbeatleast2”(50.8mm)
ID.TheoutsideairconnectionusedMUSTNOTrestricttheamountofairavailabletoyourheater.Theoutsideair
connectingpipemustbeasshortandfreeofbendsaspossible,anditmusttover,notinside,theoutsideairconnection
totheheater.
NOTE:Dimensions fromtheoor toyourheaters
inlet/exhaust pipes are approximate and may vary
dependingonyourinstallation.

TYPICALFRESHAIRTERMINATION

EXHAUST/INLETLOCATIONS




In addition to the previously detailed installation requirements, mobile home installations must meet the following
requirements:
• Theheatermustbepermanentlyattachedtotheoor.
• Theheatermustbeelectricallygroundedtothesteelchassisofthemobilehomewith8GAcopperwireusinga
serratedorstarwashertopenetratepaintorprotectivecoatingtoensuregrounding.
• Ventmustbe3or4-inch“PL”Ventandmustextendaminimumor36in.(914mm)abovetherooflineofthemobile
homeandmustbeinstalledusingaULlistedceilingrestopandraincap.
• Whenmovingyourmobilehome,allexteriorventingmustberemovedwhilethemobilehomeisbeingrelocated.
Afterrelocation,allventingmustbereinstalledandsecurelyfastened.
• OutsideAirismandatoryformobilehomeinstallation.Seeyourdealerforpurchasing.
• Checkwithyourlocalbuildingofcialsasothercodesmayapply.
Installation
USSC 13
How your heater works
Yourheaterutilizesaverticalaugerfuelfeedsystemthatisoperatedbyamicroprocessorcontrolleddigitalcircuitboard.
Thedigitalcircuitboardallowstheverticalaugerfuelfeedsystemtoruninatimer-based,non-continuouscycle;this
cyclingallowstheaugertorunforapredeterminedperiodofseconds.Theaugerpushespelletsupachutelocatedin
thehopperwhichinturnfallsthroughanotherchuteintotheburnpot.Yourheaterisequippedwithanautomaticignition
systemthatshouldignitethefuelwithin3-5minutesfrompressingthe button.Aspelletsentertheburnpotand
ignite,outsideairisdrawnacrossthefuelandheatedduringthecombustionprocesswhichisthenpulledthroughtheheat
exchangerbytheexhaustmotorordraftfan.Astheheaterheatsup,roomairiscirculatedaroundtheheatexchanger
bymeansofaroomairblower,distributingwarmairintotheroom.
Theamountofheatproducedbytheheaterisproportionaltotherateofthefuelthatisburned,andthisrateiscontrolled
bytheFuelControlbutton
.
Inordertomaintaincombustionofthefuelatadesiredrate,theairprovidedtothe
burnchamberbytheexhaustordraftfanmustbemaintainedprecisely.Toolittleairwillresultinaamethatisnon-
energeticorlazy.Ifthefuelcontinuestoowwithtoolittleairforlongenough,theburnpotwillllwithtoomuchfueland
therewillsmotherout.Tomuchairwillresultinaamethatisoveractiveoraggressive.Theameinthissituationis
typicallyveryblueatthebottomandresemblesablowtorch.Ifthissituationcontinues,thefuelintheburnpotwillbe
consumedandtherewillgoout.
Matchingtheamountofairrequiredforpropercombustiontothefuelrateistheprimaryobjectiveineffectivelyburning
pelletsofvariousbrandsandqualitiesinyourheater.Theairtofuelratiocanbeadjustedtoallowalmostanyfuelquality
toburneffectivelybyfollowingtheproceduresdetailedintheremainderofthismanual.
Becauseaforceddraftpressureisrequiredforthecombustionprocessinsideyourheater,itisextremelyimportantthat
theexhaustsystembeproperlyinstalledandmaintained.And,thatwhenoperatingyourheater,youmakesurethat
theviewingdoorisproperlysealed.

DIGITALCONTROLPANEL
Understanding your heater
14 USSC

Pressthe buttononthecontrolpadtoputtheheaterinshutdownmode.Oncethisisdone,theaugerwillstop
feedingpellets,butthedistributionblowerandexhaustblowerwillcontinuetooperate.Whentheinternaltemperature
oftheunitdropsbelowthefactorypresettemperature,thedistributionblowerandexhaustblowerwillceasetooperate
andtheunitwillbecompletelyshutdown.
Thehottertheunitisduringitsoperation,thelongeritwilltakefortheheatertocompletetheshutdowncycle.Ifthe
heaterstaysonformorethan2hoursafterpressingthe buttonandyouaresurethatthereisout,theheater
canbeunpluggedfromtheoutlet.Afterapproximately10seconds,theunitcanbere-connectedtothepowersource
andthecontrolboardwillbereset.
Ifachimneyorcreosotereoccurs,pressthe buttonimmediately.Donotunplugtheunit.

 


 



1.)Verifythatthehopperiscleanandfreeofforeignmatterincludingpelletnesanddust.
2.)Verifythatalloftherequiredexhaust/inletconnectionshavebeenmadeinaccordancewiththismanualandthatthe
heaterispluggedintoanoutlet(anoutletsurgeprotectorishighlyrecommended).
3.)Fillthehopperwithwoodpellets;donotallowanypartofthebagoranyotherforeignmaterialintothehopper,as
thismayjamtheauger.
4.)Ensurethatallpelletmatterisclearedfromthehopperseatingsurface.
5.)Closethehopperlid.
6.)Makesurethattheviewingdoorissecurelyclosed(thesafetypressureswitchwillnotallowtheheatertofeedfuel
ifthereisnodraftpressureinsidetheheater).
7.)Pressthe
buttononthecontrolpadandthenselectthehighestheatrangebypressingthe button.
8.)Theheaterwillbegintofeedfuelandthewillignitethefuelinapproximately3to5minutes.

 


Asanalternativemethodtotheinitialstartup,priortostep6above,youmayaddahandfulofpelletsoraddpelletsup
totheignitionportintheburnpot.DONOTlltheburnpotfullwithpelletsasanover-reconditionmayresult.Proceed
tostep6thru8.Thepelletsshouldigniteandheaterbeginproperoperation.
Onceaconsistentamehasbeenestablished,youcanadjusttheheatrange onthecontrolpadtoyourdesired
setting,low,medium,orhigh.(Note:Thedistributionblowerwillnotfunctionuntiltheheatexchangerintheheater
reachesthefactorypresettemperature).
Adjusttheheatrangetoamediumsettingandallowtheheatertooperateinthismannerforapproxi-
matelythree(3)hours(ormoreifnecessary),allowingtheheaterto“cureout”asthepaintandoilsfromthemanu-
facturingprocessburnoff.Werecommendthatyouopendoorsandwindowsinyourhomeduringthisprocess.
Thenadjustheatrangetoyourdesiredsetting.

Operation
USSC 15




Intheeventofa,theheaterWILLNOTfunction.Itisveryimportantthatunitbeventedproperly(with
outsideair),asthenaturaldraftisneededtoclearthesmokefromtheheaterduringapoweroutage.IftheunitwasON
whenthepoweroutageoccurred,oneofthefollowingwilltakeplace:
1.) Iftheheaterisstillwarm,itwillresumefeedingfuelandcontinuetooperatenormally.Iftherehasgoneout,you
willhavetopressthe
buttonandthenthe buttonagaintobeginanewstart-upsequence.
2.) Iftheheaterhascooled-off,itwillresettoitscondition.Atthispoint,youmaypressthe buttonandthe
unitwillbeginanewstart-upsequence.
NOTE:Theunitwillalsoshutdownintheeventofanexhaustblowerfailure;ifthisisthecase,theunitwillnotre-start
andyoumustcontactCustomerServiceat(800)750-2723.

Yourheaterincludesanasastandardfeature.Theuseofotherrestartermaterials(woodchips,
startergel,etc.)isnotnecessary.Bysimplypressingthe buttononthedigitalcontrolpanel,yourheaterwillbegin
tofeedfuelandautomaticallystartwithin3to5minutes.
Forsafety,thisheater incorporatesathathelpsensurethateverythingisinproperworking
orderbeforefeedingfueltotheburnpot.Becausetheheaterworksusinganinduceddraftpressure,theheaterwill
notcontinuetooperateiftheviewingdoorisleftopen;oriftheexhaustblowerfailsortheexhaustsystemisblocked.
The(Thermodisc)willpreventyourheaterfromoperatingatabnormallyhightemperatures.
Shouldtheheatertemperaturereachthefactorypre-setlimit,200°F(93°C),thetemperaturelimitcontrolwillautomatically
stoptheaugerfeedrateuntilthetemperaturereturnstoanormalcondition.






Creosote Formation–Whenanywoodisburnedslowly,itproducestarandotherorganicvapors,whichcombinewith
expelledmoisturetoformcreosote.Thecreosotevaporscondenseintherelativelycoolchimneyueoranewlystarted
reorfromaslow-burningre.Asaresult,creosoteresidueaccumulatesontheuelining.Whenignited,thiscreosote
makesanextremelyhotre,whichmaydamagethechimneyorevendestroythehouse.Despitetheirhighefciency,
pelletheaterscanaccumulatecreosoteundercertainconditions.
Fly Ash–Thisaccumulatesinthehorizontalportionofanexhaustrun.Thoughnon-combustible,itmayimpedethe
normalexhaustow.Itshouldthereforebeperiodicallyremoved.
Inspection and Removal–Thechimneyconnectorandchimneyshouldbeinspectedannuallyorpertontodetermineif
acreosoteoryashbuild-uphasoccurred.Ifcreosotehasaccumulated(3mmormore),itshouldberemovedtoreduce
theriskofachimneyre.Inspectthesystemattheheaterconnectionandatthechimneytop.Coolersurfacestendto
buildcreosotedepositsquicker,soitisimportanttocheckthechimneyfromthetopaswellasfromthebottom.The
creosoteshouldberemovedwithabrushspecicallydesignedforthetypeofchimneyinuse.Aqualiedchimneysweep
canperformthisservice.Itisalsorecommendedthatbeforeeachheatingseasontheentiresystembeprofessionally
inspected,cleanedand,ifnecessary,repaired.Tocleanthechimney,disconnecttheventfromtheheater.
Operation
Maintenance
16 USSC

Periodicallyremoveandcleantheburnpotandtheareainsidetheburnpothousing.Inparticularitisadvisableto
cleanouttheholesintheburnpottoremoveanybuildupthatmaypreventairfrommovingthroughtheburnpotfreely.
Ifavacuumisusedtocleanyourheater,wesuggestusingavacuumdesignedforashremoval.Someregularvacuum
cleaner(i.e.shopvacs)mayleakashintotheroom.

Ashesshouldbeplacedinasteelmetalcontainerwithatightttinglid.Theclosedcontainerofashesshouldbe
placedonanoncombustibleoororontheground,wellawayfromallcombustiblematerials,pendingnaldisposal.
Iftheashesaredisposedofbyburialinsoilorotherwiselocallydispersed,theyshouldberetainedintheclosed
containeruntilallcindershavebeenthoroughlycooled.Thecontainershallnotbeusedforothertrashorwaste
disposal.

Checkthehopperperiodicallytodetermineifthereisanysawdustorpelletsthatarestickingtothehoppersurface.
Cleanasneeded.

Inspectthemaindoorandglasswindowgasketsperiodically.Themaindoormayneedtoberemovedtohavefrayed,
broken,orcompactedgasketsreplacedbyyourauthorizedheaterdealer.

Cleantheairholesonthemotorsofboththeexhaustanddistributionblowersannually.Removetheexhaustblower
fromtheexhaustductandcleanouttheinternalfanbladesaspartofyourfallstart-up.

Paintedsurfacesmaybewipeddownwithadampcloth.Ifscratchesappear,oryouwishtorenewyourpaint,contact
yourauthorizedheaterdealertoobtainacanofsuitablehigh-temperaturepaint.

Cleaning-Werecommendusingahighqualityglasscleaner.Shouldabuildupofcreosoteorcarbonaccumulate,you
maywishtouse000steelwoolandwatertocleantheglass.DONOTuseabrasivecleaners.DONOTperformthe
cleaningwhiletheglassisHOT.,
Intheeventyouneedtoreplacetheglass,removethesix(6)screwsandglassretainers.Whilewearingleathergloves
(oranyotherglovessuitableforhandlingbrokenglass),carefullyremoveanyloosepiecesofglassfromthedoorframe.
Disposeofallbrokenglassproperly.ONLYhightemperature,ceramicglassofthecorrectsize(10.25[261]x11.06[281]
in[mm])andthickness(5mm)maybeused.DONOTsubstitutealternativematerialsfortheglass.Contactyourauthorized
dealertoobtainthisglass.Re-installthenewglassbyre-attachingtheretainersandscrews,carefulnottoovertighten
thescrewsforthiscoulddamagetheglass.
DONOTabusethedoorglassbystriking,slammingorsimilartrauma.Donotoperatetheheaterwiththeglassremoved,
crackedorbroken.

Priortostartingtherstreoftheheatingseason,checktheoutsideareaaroundtheexhaustandairintakesystems
forobstructions.Cleanandremoveanyyashfromtheexhaustventingsystem.Cleananyscreensontheexhaust
systemandontheoutsideairintakepipe.Turnallofthecontrolsonandmakesurethattheyareworkingproperly.This
isalsoagoodtimetogivetheentireheateragoodcleaningthroughout.

Afterthelastburninthespring,removeanyremainingpelletsfromthehopperandtheaugerfeedsystem.Scoopout
thepelletsandthenruntheaugeruntilthehopperisemptyandpelletsstopowing(thiscanbedonebypressingthe
buttonwiththeviewingdoorclosed).Vacuumoutthehopper.Thoroughlycleantheburnpot,andrebox.Itmay
bedesirabletospraytheinsideofthecleanedhopperwithanaerosolsiliconesprayifyourheaterisinahighhumidity
area.Theexhaustsystemshouldbethoroughlycleaned.
Maintenance
USSC 17




 Lackofcombustionairintake.
Orange/lazyame,excessivefuelbuild-upin
theburnpot
 Cleanouttheburnpot.
Makesurethattheviewingdoorisclosedandsealedproperly.Ifnot,checkorreplace
doorgaskets.
Checkthatalloutsideconnectionsareclearofanyobstructions.
Checktheexhaustsystem;cleanasneeded.
 Burnpotburnsoutoffuel
Firegoesoutorheatershutsdown.
A.Threelightsarebrightandashing.
B.Threelightsarebrightbutnotashing
C.TheREDlightisbrightandashing,butthe
otherarenot.
D.Threelightsarenotbright.
Augersystemisjammedorthereisa“bridging”ofthefuelinthehopper,preventingfuel
fromowingintotheaugerfeedsystem.CheckthattheAugermotorisfunctioning.Check
wiringandtheaugertomotorconnection.
Hopperisempty,rellthehopper.
Thehightemperaturethermodischastripped.Checkthewiringconnections.Possibly
replacethermodisc.
Lossofpower.

Lossofdraftpressure.Makesurethattheviewingdoorisclosedandsealedproperly.If
not,checkand/orreplacedoorgaskets.Checkthatalloutsideconnectionsareclearofany
obstructions.Checktheexhaustsystem;cleanasneeded.
Checkthatthepressureswitchconnectiontothereboxisfreeofashorclearofobstructions.
 
NopowerorAuto-StartIgniterfailstoignitethefuelintheburnpot.
Heaterdoesnotstartarewhenthe but-
tonispushed
 Makesurepowerissuppliedtoheater.
 TurntheheaterOFF.Cleartheunburntfuelfromtheburnpotandtryagain.
Checkthepelletquality.Replaceifmoist,wet,ordirty.
Lossofdraftpressure.Makesurethattheviewingdoorisclosedandsealedproperly.If
not,checkand/orreplacedoorgaskets.Checkthatalloutsideconnectionsareclearofany
obstructions.Checktheexhaustsystem;cleanasneeded.
 Checkthatthepressureswitchconnectiontothereboxisfreeofashorclearofobstructions.
Checkthattheauto-startigniterisnotblockedwithashorsoot.
 Theauto-startignitergets“redhot”duringstart-up.Ifyoucannotvisiblyseetheigniter
glowingduringstart-up,thentheignitermayneedtobereplacedorthereisaproblemwith
theelectricalcontrolsystem.

Heaterisoverheating.Theheaterhasbeenworkingtoolongorroomtemp.istoo
high
Twolightsarebright,thefeedinglightisoff,and
meanwhiletheorangelightisbright
 Allowheatertoshutdownautomatically,thenrestart.
 Theburnpotispositionedincorrectly.
A.Heaterdoesnotstartwhen ispressed.
B.Prolongedignitiontimewithexcesssmoke.
C.Burningisnotactive.
 Putburnpotincorrectposition,asindicatedbytheslotontheburnpot.
Trouble Shooting
USSC 19
   
1 891603 DoorFrameAssy.(5824-05-01-00) 1
A 891604 DoorFrameWldmt(5824-05-00) 1
B 891605 NylonShim(5824-08-01) 1
C 891606 DoorHndleWldmt(5824-05-02-00) 1
D 88139 GlassGasket(5824-09-00) 1
E 88140 Glass(5824-05-04) 1
F 891607 GlassRetainer(5824-05-01-09) 2
G 88141 DoorGasket(5824-08-00) 1
2 891608 FireboxFrt.Panel(5824-01-01-13) 1
3 891609 DoorHookPin(5824-01-15) 1
4 891610 HookPinTube(5824-01-16) 1
5 891611 SideWallPanel(5824-08) 1
6 891612 LeftWallPanel(5824-09) 1
7 891613 AshPanWeldment(5824-01-02-00) 1
8 891614 BurnpotSupport(5824-01-01-04) 1
9 891615 Burnpot(5824-01-10-00) 1
10 891616 Air-InGrid(5824-07-00) 1
11 891617 Air-OutGrid(5824-06-00) 1
12 891618 InsulationCover(5824-01-03) 1
13 891619 TopPanelAssy.(5824-03-00) 1
14 80562 Microswitch(5824-19-00) 1
15 891620 Micro-swHsg-1(5824-03-01-03-01) 1
16 891621 Micro-swHsg-2(5824-03-01-03-02) 1
17 891622 TopInsulationPanel(5824-01-06) 1
18 891623 TopAirGuideCover(5824-01-07) 1
19 891624 Support,TopAirGuide(5824-01-05) 2
20 891625 MaintenancePanel(5824-01-17) 1
21 891626 UpperHinge(5824-01-11-01) 1
22 891627 UpprHngFixingPin(5824-01-11-02) 1
23 891628 LowerHinge(5824-01-12) 1
24 891629 LowerHingePin(5824-01-14) 1
25 891630 HingeSleeve(5824-01-13) 1
5824
   
26 80563 DistributionMotorAssy(5824-11-00) 1
27 891631 FireboxWeldment(5824-01-01-00) 1
28 891632 VentSlides(5824-01-18) 1
29 891633 IgnitorSleeve(5824-02-12) 1
30 80564 IgnitorAssembly(5824-21-00) 1
31 891634 ExhaustHsgWld(5824-01-01-11-00) 1
32 891635 ExhastMaint.Cover(5824-01-16-01) 1
33 891636 SmokeWeldment(5824-01-09-00) 1
34 80565 ExhaustMotorAssy(5824-01-08) 1
35 80566 125°F(52°C)Sensor(5824-22-00) 2
36 891637 HopperFrame(5824-02-01-00) 1
37 891638 L/RWiringGuideRail(5824-02-03) 2
38 891639 BackWiringGuideRail(5824-02-04) 1
39 891640 BackPanel(5824-10) 1
40 80567 PressureSwitch(5824-20-00) 1
41 891641 SupportPressureSw.(5824-02-06) 1
42 891642 InsulationPanel(5824-01-04-01) 1
43 80568 198°F(92°C)Sensor(5824-23-00) 1
44 80569 CircuitBoard(5824-18-00) 1
45 80570 PowerSupplyBox(5824-17-00) 1
46 891643 Support,PwrSplyBox(5824-02-05) 1
47 80571 Capacitance(5824-16-00) 1
48 80572 Motor(5824-15-00) 1
49 891644 FeedTubeWldmt(5824-02-02-01-00) 1
50 891645 Support,Motor(5824-02-02-01-09) 1
51 891646 FeedTubeCover(5824-02-02-01-04) 1
52 891647 BigBearing(5824-11-00) 1
53 891648 SmallBearing(5824-13-00) 1
54 891649 AugerWeldment(5824-02-02-01-05) 1
N/S 891675 VermiculiteBoardFrontW/Cutout 1
N/S 891685 VermiculiteBoardFrontTop 1
N/S 891686 VermiculiteBoardSides 2
Parts List
20 USSC










C
S
S
U
C
O
M
P
A
N
Y
U
N
I
T
E
D
S
T
A
T
E
S
S
T
O
V
E






Wiring Diagram
How to Order Repair Parts
" 
" 
Ê É










  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

United States Stove 5824 Owner's manual

Category
Cookers
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI