Operating instructions
Last updated: 08.2023
EN
Control unit for hinged gates
Control x.52, Control x.52 u
+/
2 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
Table of Contents
1. Safety information ....................................3
1.1 Intended use ...................................3
1.2 Target group ...................................3
1.3 General safety advice ............................3
2. Product information ................................. 4
2.1 Scope of supply .................................4
2.2 Technical Data ..................................4
2.3 Example application .............................4
3. Installation ...........................................5
3.1 Safety instructions on assembly ..................5
3.2 Preparing for installation .........................5
3.3 Mounting the control unit ........................5
3.4 Opening the control unit .........................6
3.5 Connection of control elements ..................6
3.6 Connecting the mains cable ..................... 11
3.7 Completing the installation ......................12
4. Setting in operation ..................................12
4.1 Safety instructions for commissioning ............12
4.2 Overview of the controls ........................12
4.3 Status display .................................13
4.4 Factory settings ...............................13
4.5 Express programming ..........................14
4.6 Function test ..................................16
4.7 Special programming ...........................17
5. Operation .......................................... 26
5.1 Safety instructions for operation .................26
5.2 Operating systems .............................26
6. Care and cleaning ................................... 26
7. Maintenance ....................................... 26
7.1 Maintenance work by the operator ...............26
7.2 Maintenancebyqualiedspecialistpersonnel .....27
8. Disassembly ........................................27
9. Disposal ............................................27
10. Rectifying faults .....................................27
11. Appendix .......................................... 30
11.1 Declaration for the incorporation of a partly
completed machine ............................30
Regarding this document
Original instruction manual.
Part of the product.
Read these instructions carefully before use and keep them in a
safe place for future reference.
Protected by copyright.
No part of this manual may be reproduced without our prior
approval.
Subject to alterations in the interest of technical progress.
All dimensions are given in millimetres.
The drawings are not true to scale.
Safety instructions
WARNING!
Safety notice indicating a danger that could result in death or
severe injury.
CAUTION!
Safety notice indicating a danger that could result in slight or
moderate injuries.
ATTENTION!
Safety notice indicating a danger that could result in damage to
property or in irreparable damage to the product.
Meaning of symbols
Instruction requiring action
Check
List, itemisation
Reference to other sections of this document
Reference to separate documents that must be observed
Factory settings
Operating instructions, Control x.52, Control x.52 u (#102690 – EN) 3
EN
1. Safety information
WARNING!
Risk of death due to a failure to observe the operating manual!
This manual contains important information for handling the
product safely. Particular reference is made to possible dangers.
Read this manual through carefully.
Follow the safety instructions in this manual.
Store the manual in an accessible location.
1.1 Intended use
The operator system is to be used only for opening and closing
gates.
Use is only permissible:
In the private sector.
On swing gates.
With a suitable motor unit.
In technically faultless condition.
Following correct installation.
Incompliancewiththespecicationsinthetechnicaldata.
“2.2 Technical Data“
Any other use is deemed to be improper use.
1.2 Target group
1.2.1 Operator
The operator is responsible for the building in which the product is
used. The operator has the following tasks:
Knowledge and safekeeping of the instruction manual.
Instruction of all persons who use the door system.
Ensure that the gate system is inspected and maintained
regularlybyqualiedspecialistpersonnel.
Make sure that inspection and maintenance are documented in
the inspection logbook.
Safe and proper keeping of the inspection logbook.
1.2.2 Specialist personnel
Qualiedspecialistpersonnelareresponsibleforassembly,
commissioning, maintenance, repair, disassembly and disposal.
Requirementsapplicabletoqualiedspecialistpersonnel:
Knowledgeofthegeneralandspecicsafetyandaccident-
prevention regulations.
they have knowledge of the relevant electrical regulation,
Training in the use and care of appropriate safety equipment.
Knowledge of the application of the following standards
EN12635(“Doorsandgates-Installationanduse”),
EN12453(“Safetyinuseofpoweroperateddoors-
Requirements”),
EN12445(“Safetyinuseofpoweroperateddoors-
Testmethods”),
EN13241-1(“Industrial,commercialandgaragedoorsand
gates-Part1:Productswithoutreresistanceorsmoke
controlcharacteristics”)
Electricalworkbyqualiedelectriciansexclusively,inaccordance
with DIN VDE 0100.
Requirementsapplicabletoqualiedelectricians:
Knowledge of the basics of electrical engineering.
Knowledge of national regulations and standards.
Knowledge of the relevant safety regulations.
Knowledge of this operating manual.
1.2.3 Users
Instructed users operate and care for the product.
Requirements applicable to instructed users:
Users are instructed in relation to their work by the operator.
Users must have been instructed on how to use the product
safely.
Knowledge of this operating manual.
Special requirements apply to the following users:
Children aged eight and above.
Persons with with reduced physical, sensory or mental
capabilities.
Persons with a lack of experience and knowledge.
These users are only authorised to operate the device.
Special requirements:
The users must be supervised.
The users must have been briefed on how to use the device.
The users must understand the dangers involved in handling the
device.
Children are not allowed to play with the device.
1.3 General safety advice
Never use the gate to help lift persons or objects.
In the following cases, the manufacturer will accept no liability for
damage. The warranty on the product and accessory components
becomes void in the event of:
Failure to observe these operating instructions.
Incorrect handling and use of the product for anything other
than its intended purpose.
Workbeingcarriedoutbyunqualiedpersonnel.
Changesormodicationstotheproduct.
The use of replacement parts that have not been approved or
were not manufactured by the manufacturer.
The product is manufactured in accordance with the directives and
standards listed in the declaration of incorporation. The product
left the factory in perfect order with regard to safety.
The warranty does not cover batteries, rechargeable batteries,
fuses or bulbs.
Further safety instructions are given in the relevant sections of
the document.
“3.1 Safety instructions on assembly“
“4.1 Safety instructions for commissioning“
“5.1 Safety instructions for operation“
4 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
2. Product information
2.1 Scope of supply
Refer to the table for the supply package applicable to your
product variant.
Theremaybesomecountry-specicdifferences.
Item Control unit
11x
21x
33x
44x
54x
62x
71x
Item Hand transmitter Multi-Bit bi∙linked
81x 1x
91x –
10 – 1x
11 1x 1x
12 1x 1x
13 1x –
14 – 1x
The control unit is integrated in the following products without an
external housing:
Comfort 560
2.2 Technical Data
Electrical data
Rated voltage, regional
deviations are possible V 230 / 260
Rated frequency Hz 50 / 60
Power consumption in
operation* kW 0,4
Power consumption in standby* W 3.2
Duty cycle min. KB 5
Control voltage V DC 24
Protection class II
* without any additional equipment connected
Environmental data
Weight control unit kg 2.50
Sound pressure level dB(A) < 70
Temperature range
°C -20
°C +60
2.3 Example application
The gate construction is described in the documentation
provided with the motor unit.
Operating instructions, Control x.52, Control x.52 u (#102690 – EN) 5
EN
3. Installation
3.1 Safety instructions on assembly
WARNING!
Danger due to a failure to observe the assembly instructions!
This chapter contains important information for the safe
assembly of the product.
Read this chapter through carefully before assembly.
Follow the safety instructions.
Perform the assembly as described.
Assemblybyqualiedspecialistpersonnelonly.
“1.2.2 Specialist personnel“
Electricalworkmustbeperformedbyqualiedelectricians
exclusively.
“1.2.2 Specialist personnel“
Before assembly, it is necessary to make sure that the power
supply has been and remains disconnected. Only establish the
power supply when prompted to do so in the corresponding
assembly step.
It is essential to adhere to the local protection regulations.
It is essential that mains supply cables and control cables are
laid separately. The control voltage is 24 V DC.
All impulse transmitters and control devices (e.g. remote
control buttons) must be installed within sight of the gate and at
a safe distance from the moving parts of the gate. A minimum
installation height of 1.5 metres must be observed.
Onlyusexingmaterialthatissuitablefortherespective
construction substrate.
3.2 Preparing for installation
Before commencing installation, the following works must be
carried out without fail.
Supply package
Check that all the parts are present.
Check that all the necessary accessory parts for your
installation situation are present.
Gate system
Ensure that a suitable mains connection and a mains
disconnection facility are available for your gate system.
Theminimumcross-sectionoftheearthcableis3x1.5mm2.
Ensure that all cables are suitable for outdoor use with respect
to UV resistance and cold resistance.
Ensure that a suitable motor unit is available for your gate
system.
When using and installing accessories, always observe the
corresponding documentation.
3.3 Mounting the control unit
ATTENTION!
Danger of damage due to water ingress!
An incorrectly installed motor supply line can lead to water
ingress in the controller housing.
The control unit must be installed in such a way that the motor
cablecanbefedthroughthescrewxinginthebaseofthe
control unit.
3.3 / 1
3.3 / 2
ø 6
4 x ø6
4x
2
6 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
3.4 Opening the control unit
Comfort 560
3.4 / 1
3.5 Connection of control elements
WARNING!
Risk of fatal injury due to electric shock!
Contact with live parts can lead to electric shock, burns and
death.
Ensure that the power supply is and remains disconnected
throughout any wiring work.
ATTENTION!
Danger of material damage resulting from incorrect installation
of the operator!
If an external voltage is connected to terminal block XB03, the
entire electronic system will be irreparably damaged.
Connectonlypotential-freecontactstoterminalsB9,5,34,3
and 8 (XB99).
3.5.1 Overview of the control unit connections
3.5.1 / 1
1
2
3
4
5
6
7
8
9
0
PE N L
XN81
XB70
XN70 XB99 XP54BXP69B
XP69A XP54A
XW40
XH79XM70A XM70B
XB70 Connection for modular antenna
XB99 Connection for external control elements /
max. 50 mA
“3.5.3 Terminal XB99“
XH79 Connection for electric lock and signal
light
“3.5.5 Terminal XH79“
XM70A Connection for motor (motor unit I)
“3.5.2 Connecting the motor unit“
XM70B Connection for motor (motor unit II)
“3.5.2 Connecting the motor unit“
XN70 Connection for battery backup
XN81 Mains connection
“3.5.4 Terminal XN81“
XP54A Connection for closing edge safety device,
gate travelling direction CLOSE
“3.5.6 Terminal XP54A / XP54B“
XP54B Connection for closing edge safety device,
gate travelling direction OPEN
“3.5.6 Terminal XP54A / XP54B“
XP69A Connection for photocell, gate travelling
direction CLOSE
“3.5.7 Terminal XP69A / XP69B“
XP69B Connection for photocell, gate travelling
direction OPEN
“3.5.7 Terminal XP69A / XP69B“
XW40 Connection MS BUS
Operating instructions, Control x.52, Control x.52 u (#102690 – EN) 7
EN
3.5.2 / 3
AB
CA BC
3.5.2 / 4
A
CB
A
B C
B Gate wing motor unit I (XM70A)
C Gate wing motor unit II (XM70B)
For double wing gate systems, note the overlap (A) when
connecting the motor units.
Connect the motor units to the control unit.
3.5.2 Connecting the motor unit
ATTENTION!
Beware of danger due to motor unit malfunctions!
An incorrect connection of the motor unit can lead to
malfunctions and damage.
Passthecablethroughthecorrectscrewxing.
In the case of double wing gate systems, attach both motor
cables to the control unit.
In the case of single wing gate systems, the motor unit must
always be connected to terminal XM70A (motor unit I).
3.5.2 / 1
3.5.2 / 2
Terminal Wiring colours
A1 brown
A2 white
V5 black
11 blue
15 violet
10 red
Connect the motor cable wires to the motor connector.
8 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
3.5.3 Terminal XB99
Factory default settings
B9 and 5 bridged
3.5.3 / 1
-XB99
B9 534 3 8
M06E039
The connection arrangement depends on the programming of the
special functions. Depending upon the programming, it is possible
to connect impulse or directional pushbuttons.
“4.7 Special programming“
If a closing prevention device (photocell, timer, …) is connected
to XB99, the controls will recognize it automatically after “Mains
On”(contactSB34mustbeclosed).
Only in conjunction with automatic closing timer.
When the contacts of a closing prevention device are open, the
gate can be closed only in deadman mode.
Additional external control elements and safety devices with a
24 V connection (50 mA maximum) must be connected to XB99.
Connection option number 1
3.5.3 / 2
-SB5
12 11
-SB8
14 13
-XB99
B9 534 3 8
M06E039
Connection option number 2
3.5.3 / 3
-SB5 12 11
-SB3 14 13
-SB8 14 13
-XB99
B9 5 34 3 8
-SB34 14 13
M06E039
Connection option number 3
3.5.3 / 4
-XB99
B9 534 3 8
-XP69A
P6 27
-X1+-
-S1
14 13
21
M12E016
+ 24 V DC connection (50 mA max.)
GND connection
1Connectionofpotential-freenormallyopen
contact
2Connectionofpotential-freenormallyopen
contact
3 Active wing / impulse connection
5 STOP connection
8 Impulse connection
26 Photocell connection
34 Connection
“Level5,Menu3-Programmableinput“
B9 +24 V DC connection (50 mA max.)
P6 GND connection
S1 Receivernormallyopencontact,potential-
free
SB3
Button
“Level5,Menu1-Programmableimpulse
input“
SB5 STOP button
SB8
Button
“Level5,Menu1-Programmableimpulse
input“
SB34 Closing prevention device button (photocell)
/ operator system stops and reverses
X1 Connection for external receivers
XP69A Connection for photocell, gate travelling
direction CLOSE
Operating instructions, Control x.52, Control x.52 u (#102690 – EN) 9
EN
3.5.4 Terminal XN81
3.5.4 / 1
M07E039
M12E019
FO Customers protective equipment
51 Electric lock connection
L Phase connection
N Neutral conductor connection
PE Protective earth connection
X0 Customersmainsconnection,withall-pole
disconnect
“3.6 Connecting the mains cable“
3.5.5 Terminal XH79
Connection option 1
Signal light 24 V DC / electric lock 24 V DC
3.5.5 / 1
M12E019
Connection option 2
Signal light connection with external relay
3.5.5 / 2
M12E019
49 Connection for programmable output
“Level1,Menu7-Signallightoutput“
51 Connection for electric lock
H7 24V DC connection / max. 1.0 A
HH14 Signal light 230 V AC
HH49 Signal light 24 V DC
KH49 Users relay 24 V
L Phase connection
N Neutral wire connection
YH51 Electric lock (provided by the customer)
10 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
3.5.6 Terminal XP54A / XP54B
ATTENTION!
Failure to make connections correctly can result in material
damage.
Ifan8.2kΩcontactstripclosingedgesafetydeviceisconnected,
the8.2kΩresistorsinstalledatterminalsXP54Bclosingedge
OPEN and XP54A closing edge CLOSE must be removed.
3.5.6 / 1
- XP54A P5 47
8K2
M07E037
P5 GND connection
46
Connection for signal of closing edge safety
device
Gate travelling direction OPEN (XP54B)
47
Connection for signal of closing edge safety
device
Gate travelling direction CLOSE (XP 54A)
3.5.7 Terminal XP69A / XP69B
3.5.7 / 1
M12E017
26 Connection for signal photocell,
gate travelling direction OPEN (XP69B)
27 Connection for signal of photocell,
gate travelling direction CLOSE (XP69A)
P6 GND OPEN connection (XP69B)
GND CLOSE connection (XP69A)
RX Receiverforthetwo-wirephotocell
TX Transmitterforthetwo-wirephotocell
Atwo-wirephotocellconnectedtoterminalsX69A/XB69Bwillbe
recognisedautomaticallybythecontrolsafter“MainsOn”.
The photocell can be deactivated later (Level 8 / Menu 1).
Atwo-wirephotocellfortheOPENdirectioncanonlybeinstalledif
atwo-wirephotocellisavailableintheCLOSINGdirection.
If a photocell is connected, it will be switched off in energy saving
mode.
Operating instructions, Control x.52, Control x.52 u (#102690 – EN) 11
EN
3.6 Connecting the mains cable
WARNING!
Risk of fatal injury due to electric shock!
Contact with live parts can lead to electric shock, burns and
death.
Ensure that the power supply is and remains disconnected
throughout any wiring work.
If the mains cable is connected via a permanent mains
connection,thisconnectionmusthaveanall-pole
disconnection switch.
ATTENTION!
Danger of material damage resulting from incorrect installation
of the operator!
An incorrectly installed motor supply line can lead to water
ingress in the controller housing.
Run the cable through the cable gland in the base of the
controller.
3.6 / 1
3.6 / 2
1
2
3
4
5
6
7
8
9
0
PE N L
A
A
A
A
3.5.8 Connection to different makes of photocell
3.5.8 / 1
M12E017a
+ Connection of supply voltage
Connection of supply voltage
13 Relay contact input
14 Relay contact output
26 Connection for photocell OPEN
27 Connection for photocell CLOSE
AP26 Relay photocell
AP27 Relay photocell
B9 +24V DC connection
P6 GND connection
RX Photocell receiver RX
TX Photocell transmitter TX
XB99 External control elements connection
XP69A Connectionterminalfor2-wirephotocell
CLOSE
XP69B Connectionterminalfor2-wirephotocell
OPEN
12 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
Comfort 560
3.6 / 3
L N
PE
1
2
3
4
5
6
7
8
9
0
A
A
A
A
A Split ferrite
3.7 Completing the installation
Before closing the control unit, the following work must be carried
out:
“4. Setting in operation“
3.7 / 1
4. Setting in operation
4.1 Safety instructions for commissioning
WARNING!
Danger due to a failure to observe the commissioning
instructions!
This chapter contains important information for the safe
commissioning of the product.
Read this chapter through carefully before commissioning.
Follow the safety instructions.
Perform commissioning as described.
Commissioningmustbeperformedbyqualiedspecialist
personnel.
“1.2.2 Specialist personnel“
Power-operatedwindows,doorsandgatesmustbeinspectedby
qualiedspecialistpersonnelbeforerstcommissioningandas
required, although at least once a year, with a suitable closing force
measuring device (written inspection records must be kept).
After setting the system in operation, the operator of the gate
system, or the operators representatives, must be instructed in the
operation of the system.
Childrenmustnotplaywiththegatecontrolunitorthehand-
held transmitter.
No persons or objects are permitted inside the operating range
of the gate.
Before passing through the gate opening, make sure the gate is
in the OPEN gate position.
All available emergency command devices must be tested.
Pay attention to any parts of the gate system that could cause
crushing or shearing damage.
Never insert your hands into a running gate, the guide rails or
moving parts.
TheEN13241-1regulations(“Gates-productstandard”)mustbe
observed.
4.2 Overview of the controls
Control elements
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
LED display
Drive the gate in the OPEN direction, increase
the value
Drive the gate in the CLOSE direction,
decrease the value
PStartprogramming,conrmandsavevalues
Operating instructions, Control x.52, Control x.52 u (#102690 – EN) 13
EN
Minute indicator
1
2
3
4
5
6
7
8
9
0
Times exceeding one minute are shown in
minutes and seconds.
Example: 1.2 = 1 minute + 20 seconds =
80seconds
4.3 Status display
Display Function / Element
1
Reference point of GATE 1 is approached
2
Reference point of GATE 2 is approached
3
Battery backup connected (optional)
(LED3ashing=batteryrecharging)
4
Warning time indicator (only for programmed
automatic closing)
4.4 Factory settings
Using the reset procedure, the operator parameters can be
restored to their original factory settings.
“Level 1, Menu 8 – RESET“
Legend
Thedisplayashes
Display lights up
Display Function / Element
Ready for operation
Gate position: CLOSED
Gate position: OPEN
Fault message / Maintenance indicator in
CLOSED gate position
Photocell or closing edge safety device
Remote control
External button activated
1
Status display
(example: 1 – Reference point of GATE 1 is
approached)
“4.3 Status display“
1
2
3
4
5
6
7
8
9
0
Level indicator (example: Level 2)
1
2
3
4
5
6
7
8
9
0
Menu and parameter indicator
(example:Menu3,Parameter8)
Display, gate 1
Display, gate 2
14 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
4.5 Express programming
To set the operator system properly in service and after every
reset, the express programming procedure must be carried out.
Requirements:
The gate must be in the CLOSED position.
The carriage must be coupled up.
A description of the operator locking mechanism release can be
found in the documentation for the motor unit.
When in programming mode, the controls will revert automatically
to operating mode if a period of 120 seconds passes without any
buttons being pressed.
A corresponding fault number will be displayed.
“10. Rectifying faults“
Carry out the express programming procedure.
A function test must be carried out after express programming.
“4.6 Function test“
4.5.1 Comfort 5xx with reference point technology
(6cores)
“Level5,Menu6-Controlunitversion“
3 Comfort 5xx single wing reference point
4 Comfort 5xx double wing reference point
Express programming
1. Programming the “OPEN” gate position (Gate 1)
The control system is in
operating mode.
PP > 3 sec. < 10 sec.:
Start express programming.
Drive the gate to the OPEN
position.
P
Save the OPEN position.
2-wing gate system
Continue with step 2
1-wing gate system
Continue with step 4
1. Programming the “OPEN” gate position (Gate 2)
Drive the gate to the OPEN
position.
PSave the OPEN position.
Operating instructions, Control x.52, Control x.52 u (#102690 – EN) 15
EN
Express programming
3. Programming the “CLOSED” gate position (Gate 2)
Drive the gate to the CLOSED
position.
PSave the CLOSED position.
4. Programming the “CLOSED” gate position (Gate 1)
Drive the gate to the CLOSED
position.
PSave the CLOSED position.
5. Programming the remote control
Only bi•linked version:
Press the programming
button inside the hand
transmitter.
Press the hand transmitter
button.
Release the hand transmitter
button.
PSave the remote control
setting.
End express programming.
The control system is in
operating mode.
4.5.2 Comfort 515 with limit switch technology (2 cores)
“Level5,Menu6-Controlunitversion“
1 Comfort 515 single wing limit switch
2 Comfort 515 double wing limit switch
Express programming
1. Programming the gate position OPEN and CLOSED (gate 1)
The control system is in
operating mode.
PP > 3 sec. < 10 sec.:
Start express programming.
Set the gate position OPEN
and CLOSED for gate 1.
Comfort 515 operating
instructions. Chapter 3.7
P
Save gate positions for
gate 1.
2-wing gate system
Continue with step 2
1-wing gate system
Continue with step 3
2. Programming the gate position OPEN and CLOSED (gate 2)
Set the gate position OPEN
and CLOSED for gate 2.
Comfort 515 operating
instructions. Chapter 3.7
PSave gate positions for
gate 2.
16 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
Express programming
3. Programming the remote control
Only bi•linked version:
Press the programming
button inside the hand
transmitter.
Press the hand transmitter
button.
Release the hand transmitter
button.
PSave the remote control
setting.
End express programming.
The control system is in
operating mode.
4.6 Function test
4.6.1 Programming run for setting the driving power
Duringthersttworunsafterthegatepositionshavebeen
programmed, the operator system determines the maximum
required driving power.
Drive the operator system (with the gate coupled up) from the
CLOSED gate position to the OPEN position and back again,
without interruption.
Aqualiedspecialistmusttestthedrivingpowerwithaforcetester
designed for this purpose.
Check the function
1. The control system is in
operating mode.
2.
The gate should open and
movetothesaved“OPEN”
gate position.
3.
The gate should close and
move to the saved “CLOSED“
gate position.
4.
The gate operator should
move the gate in the OPEN or
CLOSE direction.
5.
The operator system should
stop.
6. The operator system should
run in the opposite direction.
Operating instructions, Control x.52, Control x.52 u (#102690 – EN) 17
EN
4.6.2 Checking the automatic cut-out
WARNING!
Risk of injury due to operation without automatic cut-out!
Thedriveisequippedwithanautomaticcut-outforpersonal
protection.
Only ever operate the product if the correct function of the
automaticcut-outisguaranteed.
Checktheautomaticcut-outfunctionintheOPENand
CLOSE directions.
Automatic cut-out
All gate systems must be in compliance with EN 13241 when tested.
Place an obstacle in the path of the gate in both the OPEN and
CLOSE directions.
For each direction, drive the gate into the obstacle.
The operator system should stop and reverse when it touches
the obstacle.
The settings for the driving power in the OPEN and CLOSE
directions remain saved even if the mains power supply is
interrupted.
The parameters are returned to the factory settings only after a
reset.
“Level 1, Menu 8 – RESET“
4.6.3 Checking the photocell
Check all the photocells individually by triggering them.
Check all the closing edge safety devices individually by
triggering them.
4.7 Special programming
WARNING!
In order to guarantee personal protection, the gate forces
mustcomplywithspeciedlimitvalues.Iftheparametersare
changed, these limit values could be exceeded. After changing
the settings, it is therefore necessary to check the gate forces
to guarantee safe operation.
Testtheautomaticcut-out.
“4.6.2Checkingtheautomaticcut-out“
Commissionaqualiedspecialistwithtestingthedriving
power using a force tester designed for this purpose.
After a reset, all the parameters are returned to the factory
settings. Safety elements that are operational and are connected
to the system will be recognised anew after a reset.
Connected further accessories must be reprogrammed after a
reset.
To ensure that the controls functions properly:
Reprogram all the required functions.
Reprogram the remote control.
Drive the operator system once to the OPEN position and then
the CLOSED position.
If a photocell is connected, it will be automatically detected by the
control system as soon as the power supply is connected.
The photocell can be reprogrammed later.
Photocells that are not required must be disconnected before the
power supply is connected; otherwise they will be recognised by
the controls.
“3.5.7 Terminal XP69A / XP69B“
In the case of double wing gates, certain parameters for gate 1 and
gate 2 are set separately.
A function test must be carried out after changes have been
made in programming mode.
“4.6 Function test“
18 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
4.7.1 Programming the special functions
Programming procedure
1. The control system is in
operating mode.
2. P
P > 10 sec.:
Start programming the
extended operator functions.
Display the levels.
1
2
3
4
5
6
7
8
9
0
3. Select the level required
(example: Level 2).
1
2
3
4
5
6
7
8
9
0
4. PConrmthelevelrequired.
Displaytherstmenuand
the programmed parameter.
1
2
3
4
5
6
7
8
9
0
5. Select the menu required
(example Menu 3).
1
2
3
4
5
6
7
8
9
0
6. PConrmthemenurequired.
Display the programmed
parameter value.
1
2
3
4
5
6
7
8
9
0
7. Change the parameter value.
1
2
3
4
5
6
7
8
9
0
8. PSave the parameter value.
The control system switches
to display the levels
1
2
3
4
5
6
7
8
9
0
Programming procedure
9.
Select the next level
required.
Continue programming.
1
2
3
4
5
6
7
8
9
0
or
P
P > 5 sec.:
Finish programming.
All the altered parameters
are saved.
The control system is in
operating mode.
4.7.2 Overview of the special functions
Level Menu
1
Basic functions
3 Intermediate OPEN position
(only for single wing gates –
not Comfort 515)
4 Intermediate CLOSE position
(only for single wing gates –
not Comfort 515)
7 Signal light output
8 RESET
2
Operator settings
1 Driving power required to OPEN
2 Driving power required to CLOSE
3 Automaticcut-outintheOPEN
direction
(not Comfort 515)
4 Automaticcut-outintheCLOSE
direction
(not Comfort 515)
3
Automatic
closing timer
1 Automatic closing timer
3 Gate open duration
4 Warning time
5 Start-upwarning
7 Signal light
4
Remote
programming
2 Intermediate OPEN position
3 Intermediate CLOSE position
(only for single wing gates –
not Comfort 515)
4 OPEN
5 CLOSE
8 Operator lighting ON / OFF
Operating instructions, Control x.52, Control x.52 u (#102690 – EN) 19
EN
Level Menu
5
Special functions
1 Programmable impulse input
2 Motor unit start delay
3 Programmable input
4 Lighting duration
5 Hand-heldprogrammingdevice
6 Control unit version
7 Batteryback-up
8 Magnetic lock version
6
Variable
speed
1 OPEN speed
2 Soft run OPEN speed
3 Soft run OPEN position
(not Comfort 515)
4 CLOSE speed
6 Soft run CLOSE speed
8 Soft run CLOSE position
(not Comfort 515)
7
Maintenance and
servicing
1 Gate cycle counter
2 Servicing counter
3 Servicing interval
8 Fault log reset
9 Fault indicator
8
System settings
1 Photocell
2 Closing edge safety device
3 Automaticcut-outfunction
(not Comfort 515)
4 Operating modes
5 Function of the direction command
transmitters
6 Function of the impulse command
transmitters
9 Changing the display language
4.7.3 Contents of the special functions
Level 1 – Basic functions
Menu 3 – Intermediate OPEN position
(only for single wing gates – not Comfort 515)
Adjust the setting using the + (OPEN) and – (CLOSE)
buttons.
The closing function with automatic closing is
possible.
Level 1 – Basic functions
Menu 4 – Intermediate CLOSE position (only for single wing
gates – not Comfort 515)
Adjust the setting using the + (OPEN) and – (CLOSE)
buttons.
The closing function with automatic closing is not
possible.
Menu 7 – Signal light output
(only programmable with optional signal light relay)
1 Signal light
“Level3,Menu7-Signallight“
2 Gate position: OPEN
3 Gate position: CLOSED
4
Intermediate OPEN position (only for single wing
gates)
5Intermediate CLOSE position
(only for single wing gates)
6Operator system starts (wiping impulse, 1
second)
7 Fault
8Lighting(3-minutelight)
“Level5,Menu4-Lightingduration“
9Locking mechanism release
(operator system running)
10 Locking mechanism release
(operator system inmobile)
11 Release lock (operator system starts /
wiping impulse, 3 seconds)
12 Push-opensecuritydevice
13 Radio remote control (relay is activated for the
duration of the impulse – only Multibit)
14
Test impulse for the closing edge safety device
(relay transmits a test impulse and is activated
for300ms)
20 Operating instructions, Control x.52, Control x.52 u (#102690 – EN)
Level 2 – Gate operator settings
Menu 2 – Driving power required to CLOSE
Drives with a reference point (Comfort 5xx) learn the
driving power independently.
“4.6.1 Programming run for setting the driving
power“
Gate 1:
Sensitivity in on a scale of 1 to 16
(the higher the number, the greater the driving
power).
7 (only Comfort 515)
Gate 2:
Sensitivity in on a scale of 1 to 16
(the higher the number, the greater the driving
power).
7 (only Comfort 515)
Menu 3 – Automatic cut-out in the OPEN direction
(not Comfort 515)
Gate 1:
Sensitivity on a scale of 1 (OFF) to 16
(the lower the number, the more sensitive the
automaticcut-out).
8
Gate 2:
Sensitivity on a scale of 1 (OFF) to 16
(the lower the number, the more sensitive the
automaticcut-out).
8
Menu 4 – Automatic cut-out in the CLOSE direction
(not Comfort 515)
Gate 1:
Sensitivity on a scale of 1 (OFF) to 16
(the lower the number, the more sensitive the
automaticcut-out).
8
Gate 2:
Sensitivity on a scale of 1 (OFF) to 16
(the lower the number, the more sensitive the
automaticcut-out).
8
Level 1 – Basic functions
Menu 8 – RESET
The operator system can be reset to the factory
settings.
1 No reset
2
Reset the controls (Factory setting)
Connectedmodules(BUS-Module,bi·linked)must
be reset separately.
3 Reset the remote control (telegrams are deleted)
4
Reset the special function: automatic closing
timer
“Level3-Automaticclosingtimer“
5
Reset only the special operator functions
(except the OPEN/CLOSED gate positions and
the remote control impulse)
6Reset the safety elements (photocell / Hold
circuit)
7Reset bus modules (connected bus modules will
be programmed in)
Level 2 – Gate operator settings
Menu 1 – Driving power required to OPEN
Drives with a reference point (Comfort 5xx) learn the
driving power independently.
“4.6.1 Programming run for setting the driving
power“
Gate 1:
Sensitivity in on a scale of 1 to 16
(the higher the number, the greater the driving
power).
7 (only Comfort 515)
Gate 2:
Sensitivity in on a scale of 1 to 16
(the higher the number, the greater the driving
power).
7 (only Comfort 515)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Marantec Control x.52 Owner's manual

Category
Gate Opener
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI