External vibrators Satety Instructions
SV00040GB 5
2.1 Safety checks
2.1.1 The functionability of the control and safety facilities is to be checked
before work is commenced.
2.1.2 Roughly 3 hours after initial commissioning or repair work,
subsequently at regular intervals, check that all external threaded
fasteners, especially the attachment screws for the baseplates and the
key connection, are tight and retighten, if necessary.
2.1.3 Immediately inform your superior should damages be determined at
the safety devices or other damages which could impair the safe
operation of the external vibrator.
2.1.4 In caseof defects jeopardizingthe operational safetyof the converters,
the machine has to be switched off immediately.
2.1 Maintenance
2.1.1 Only use original spare parts. Modifications to this machine, are
subject to the express approval of Wacker. In case of nonobservance
all liabilities shall be refused.
2.1.2 The external vibrator is to be disconnected from the mains supply
during maintenance and repair works.
2.1.3 Work on the electric parts of the machines may only be carried out by
skilled technicians.
2.1.4 The green / yellow protective earth conductor of the connection cable
must be longer so that it does not become detached if the strain relief
clamp fails. There is a danger to life and limb if this connection is
broken. After repair work, check protective earth conductor for
continuity. The protective earth conductor is dispensed with on totally
insulated machines and equipment with protective potential.
2.1.5 As soon as maintenance and repair jobs have been completed, all
safety devices have to be reinstalled properly.