TIS IO-OUT-HOTEL Product information

  • Hello, I have analyzed the product diagrams for the TIS IO-OUT-HOTEL and IO-OUT-HOTEL-RF card power switches. This document provides details on their connection to the TIS BUS Network via Cat5e cables, including diagrams for doorbells and light switches. I'm ready to answer your questions about these devices.
  • What type of cable is used for the TIS BUS Network connection?
    What is the color code for the +24V connection?
    What is the primary function of the IO-OUT-HOTEL device?
Product Diagrams V 1.2 Model: IO-OUT-HOTEL
TIS IO OUT HOTEL
Card Power Switch with Service Indicators
IO OUTDOOR PANEL
Model: IO-OUT-HOTEL-RF
www.tissmarthome.com
R7 R8
C2
VD4
L1
089
E3 Q4 C20 C26
DND CLEAN LUNDARY CARD GND RIN ROUT
R1
C1 E1
R3
VD6
E2
F3
D3
N1
+24V D+ D- GND
C4
Q1
VD1
F1
F2
R2
ac
ac
REMOVE
AFTER
WASHING
HF04
227A
ac
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
Cat5e connection
+24V(brown-orange)
D+(blue-green)
Cat5e
to the TIS BUS Network
IO-OUT-HOTEL-RF
Figure 1: IO-OUT-HOTEL Module’s Bus Connection Color Coding
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL .
All of the specification are subject to change without notice.
TIS IO OUT HOTEL
Card Power Switch with Service Indicators
Model: IO-OUT-HOTEL
IO OUTDOOR PANEL
Model: IO-OUT-HOTEL-RF
www.tissmarthome.com
R7 R8
C2
VD4
L1
089
E3 Q4 C20 C26
DND CLEAN LUNDARY CARD GND RIN ROUT
R1
C1 E1
R3
VD6
E2
F3
D3
N1
+24V D+ D- GND
C4
Q1
VD1
F1
F2
R2
ac
ac
REMOVE
AFTER
WASHING
HF04
227A
ac
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
Cat5e connection
+24V(brown-orange)
D+(blue-green)
1.5 mm Electric Cable
1.5 mm Electric Cable
low voltage cable
low voltage cable
Door Bell
Connect To L
Connect To N
Cat5e
to the TIS BUS Network
IO-OUT-HOTEL-RF
AC/DC ADAPTER
Input 110~220V AC
Output 12V DC
Figure 2: IO-OUT-HOTEL & Door Bell Unit Connection Diagram
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL .
All of the specification are subject to change without notice.
TIS IO OUT HOTEL
Card Power Switch with Service Indicators
Model: IO-OUT-HOTEL
IO OUTDOOR PANEL
Model: IO-OUT-HOTEL-RF
www.tissmarthome.com
R7 R8
C2
VD4
L1
089
E3 Q4 C20 C26
DND CLEAN LUNDARY CARD GND RIN ROUT
R1
C1 E1
R3
VD6
E2
F3
D3
N1
+24V D+ D- GND
C4
Q1
VD1
F1
F2
R2
ac
ac
REMOVE
AFTER
WASHING
HF04
227A
ac
Cat5e to the TIS BUS Network
L
S
S
L
L1
S1
S1
S2
L2
L1
S2
L2
PLEASE
DISTURB
DO NOT
WASH LAUNDRY MAKEUP ROOM
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cate5e connection
low volage cable
low volage cable
GND(white-orange)&(white-brown)
Figure 3: IO-OUT-HOTEL & Traditional Light Switch Connection Diagram
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL .
All of the specification are subject to change without notice.
TIS IO OUT HOTEL
Card Power Switch with Service Indicators
Model: IO-OUT-HOTEL
129mm
94mm 13mm
Figure 4: IO-OUT-HOTEL Module’s Dimensions
/