15
!0 ELECTRICAL AND PLUMBING
ELECTRICAL SPECIFICATIONS FREEZER REFRIGERATOR
Supply 230 VAC, 50 Hz 230 VAC, 50 Hz
Service 10 amp circuit 10 amp circuit
Socket 3-pin earthing-type 3-pin earthing-type
Power cord (excluding plug) 2190mm 2190mm
PLUMBING SPECIFICATIONS FREEZER REFRIGERATOR
Supply 1/2” BSP threaded water connection 6.35mm PEX tubing NA
Pressure psi (kPa) min 22 (150) / max 827 (120) @ 68°F (20°C) NA
Water inlet hose 2121mm 2121mm
Electrical and water connections must be within this space if located
behind the appliance and must not protrude from the back wall.
ELECTRICAL AND PLUMBING DIMENSIONS mm
AOverall height of supply area 229
BOverall depth of supply area 25
CWidth of notch in supply area (both sides) 13
DHeight of sides of supply area (both sides) 127
Note: Dimensions are based on minimum depth of cavity.
Image shown is for single install.
For dual install, each appliance should have a separate
power supply connection with only the freezer having
a water connection.
Model no:
RS24W84RJ1
IMPORTANT!
For ease of installation, ensure cavity has consistent dimensions
top to bottom and left to right.
Minimum Cavity Dimensionsm
a Overall height of cavity213
B Overall width of cavity61
c Overall depth of cavity63
Electrical / Plumbing Supply Dimensions mm
d Overall height of supply area 229
E Overall depth of supply area 25
F Width of notch in supply area (both sides) 13
G Height of sides of supply area (both sides) 12
Specifications
Electrical
SupplyAUS/NZ 230 VAC, 50 Hz / US/CA 115 VAC, 60 Hz
Service 10 amp circuit
Plumbing
Supply1/4" (6mm) comp. stainless steel braided hose
Pressure min 150 kPa (22 psi
max 827 kPa (120 psi) @ 20°C (68°F)
NOTE: Electrical connection can be located an adjacent cabinet to either side
of the fridge or above the fridge cavity.
DATE: 01.03.2018
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Please read the installation manual for detailed information on installing the
product. For full installation instructions & specifications visit fisherpaykel.com
CAVITY PREPARATION - FRAMELESS
610mm Columns Built-In Fridge
ISO VIEW OF CAVITY
A
C
Left side of cavity
REAR OF CAVITY
Floor
Note: We recommend to use an isolating switch that is easily accessible to the user after the
appliance is installed.
WARNING!
Electric shock hazard! Assume all parts live. Disconnect supply before servicing
and installation.
Model no:
RS24W84RJ1
IMPORTANT!
For ease of installation, ensure cavity has consistent dimensions
top to bottom and left to right.
Minimum Cavity Dimensionsm
a Overall height of cavity213
B Overall width of cavity61
c Overall depth of cavity63
Electrical / Plumbing Supply Dimensions mm
d Overall height of supply area 229
E Overall depth of supply area 25
F Width of notch in supply area (both sides) 13
G Height of sides of supply area (both sides) 12
Specifications
Electrical
SupplyAUS/NZ 230 VAC, 50 Hz / US/CA 115 VAC, 60 Hz
Service 10 amp circuit
Plumbing
Supply1/4" (6mm) comp. stainless steel braided hose
Pressure min 150 kPa (22 psi
max 827 kPa (120 psi) @ 20°C (68°F)
NOTE: Electrical connection can be located an adjacent cabinet to either side
of the fridge or above the fridge cavity.
DATE: 01.03.2018
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Please read the installation manual for detailed information on installing the
product. For full installation instructions & specifications visit fisherpaykel.com
CAVITY PREPARATION - FRAMELESS
610mm Columns Built-In Fridge
ISO VIEW OF CAVITY
A
C
D
B
Electrical
Plumbing
Electrical