Chore-Time MF2476A ATF Control Pan Light Installation and Operators Instruction Manual

Type
Installation and Operators Instruction Manual

Chore-Time MF2476A ATF Control Pan Light is a safety and control device designed to enhance the functionality and safety of your feeding system. It features a durable construction and weather-resistant design, making it suitable for various agricultural environments. The light assembly includes a water-tight connector and a plastic bushing for secure and reliable operation. The device can be easily installed on the pan shield using the provided mounting hardware.

Chore-Time MF2476A ATF Control Pan Light is a safety and control device designed to enhance the functionality and safety of your feeding system. It features a durable construction and weather-resistant design, making it suitable for various agricultural environments. The light assembly includes a water-tight connector and a plastic bushing for secure and reliable operation. The device can be easily installed on the pan shield using the provided mounting hardware.

ATF Control Pan Light (230 VAC)
Part No. 55495
Installation and Operators Instruction Manual
Contact your nearby Chore-Time distributor or representative for additional parts and information.
Chore-Time Group
A division of CTB, Inc.
PO Box 2000
Milford, Indiana 46542-2000 USA
Phone (574) 658-4101 Fax (877) 730-8825
Internet: www.choretimepoultry.com
MF2476AFeb 2018
Installation and Operators Manual
Installation and Operators Manual
Contents
Topic Page
MF2476A
2
Safety and General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Follow Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Decal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DANGER: Moving Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DANGER: Electrical Hazard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Light Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cutting out Hole Drilling Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Drilling Holes in Pan Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cord hole. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Light Mounting Holes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Attaching the Light to the Pan & Install Plastic Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Drilling Hole in Switch Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ATF Pan Light Wiring with Electronic Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
DANGER: Electrical Hazard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical disconnects and over current protection are not supplied with the equipment. . . . . . . . . . . . . . . 9
ATF Pan Light with Mechanical Switch Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Parts Listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
ATF Control Pan Light (230 VAC) Safety and General Information
3
MF2476A
Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous
situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or
damaged safety decals immediately.
Safety–Alert Symbol
This is a safety–alert symbol. When you see this symbol on your equipment, be alert to the potential
for personal injury. This equipment is designed to be installed and operated as safely as
possible...however, hazards do exist.
Understanding Signal Words
Signal words are used in conjunction with the safety–alert symbol to identify the severity of the warning.
DANGER indicates an imminently hazardous situation which, if not avoided, WILL result in death or
serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, COULD result in death or
serious injury.
CAUTION indicates a hazardous situation which, if not avoided, MAY result in minor or moderate
injury.
Follow Safety Instructions
Carefully read all safety messages in this manual and on your equipment safety signs. Follow recommended
precautions and safe operating practices.
Keep safety signs in good condition. Replace missing or damaged safety signs.
Decal Descriptions
DANGER: Moving Parts
Disconnect electrical power before working on system, equipment may
start automatically. Otherwise personal injury will result.
Severe personal injury will result if the equipment is operated without
covers properly installed.
DANGER: Electrical Hazard
Disconnect electrical power before inspecting or servicing equipment unless
maintenance instructions specifically state otherwise.
Ground all electrical equipment for safety.
All electrical wiring must be done by a qualified electrician in accordance with
local and national electric codes.
Ground all non-current carrying metal parts to guard against electrical shock.
Electrical disconnects and over current protection are not supplied with the
equipment.
Safety and General Information
Assembly ATF Control Pan Light (230 VAC)
4
MF2476A
Light Assembly
Assembly
(55494)
Figure 1.Light Assembly
Screw locked in place
(55497) Pan Light Bracket
ATF Pan Light
Split to allow
for Wires
Install Water Tight
(23779)
Tighten
Install Tubing
(14454-10)
Tighten
(55497) Pan Light Bracket
(55494)
ATF Pan Light
Water Tight
(23779)
Tubing
(14454-10)
Plastic Nut
(43662)
(43662)
Plastic Nut
Assembly ATF Control Pan Light (230 VAC)
5
MF2476A
Cutting out Hole Drilling Template
1.Cut out the Templates below. Cut on the dashed lines for ATF Plus Feeders.
Important! Do Not cut out the holes!
Cut on Solid Line
Cut on Dashed Line
(All Feeders)
for ATF Plus Feeders
.875 Ø
.203 Ø
.875 [22.23mm] Ø Cord Hole Template
L
i
g
h
t
M
o
u
n
t
i
n
g
H
o
l
e
Cut on Solid Line
(All Feeders)
ATF Plus
Standard ATF
Figure 2.Hole Drilling Template
T
e
m
p
l
a
t
e
[22.3mm Ø]
Assembly ATF Control Pan Light (230 VAC)
6
MF2476A
This page left blank intentionally.....
ATF Control Pan Light (230 VAC) Assembly
7
MF2476A
Drilling Holes in Pan Shield
Cord hole
1.Line up the Cord Hole Template you cut out earlier as shown in Figure 3 below.
2.Make sure you have cut the template correctly for your application. (ATF Plus/Standard)
3.Use the Template as a guide, and use a Uni-Bit to drill a .875Ø [22.23mm] hole.
Light Mounting Holes
1.Line up the Light Hole Template as shown in Figure 4 below.
2.Use the Template as a guide to drill (2) .203Ø [5.16mm] holes.
Drill a .875 [22.23mm] Ø Hole
Figure 3.Drilling the Cord Holes
.875Ø Uni-Bit
Template
Figure 4.Drilling Light Mounting Holes
Template
Drill (2) .203 [5.16] Ø holes
Assembly ATF Control Pan Light (230 VAC)
8
MF2476A
Attaching the Light to the Pan & Install Plastic Bushing
1.Snap the Plastic Bushing (3326) into the .875Ø Hole as shown.
2.Attach the Light Assembly to the Shield with (34019) 10-24 Lock Nuts as shown.
Drilling Hole in Switch Control Box
1.Use a Uni-Bit to drill a .875Ø [22.23mm] hole in the Switch Box as shown.
1.Install a Water Tight Connector (23779) in the hole.
2.Route the Light wiring (Black Tube) through the Plastic Bushing and through the Water Tight Connector and
tighten.
(3326)
Figure 5.Attaching the Light to the Shield
(34019)
10-24 Lock Nut
Plastic Bushing
View under Shield
2434-007b 03/2014
Figure 6.Drilling Hole in Switch Box
1-1/4" [31.75 mm]
7/8" [22.23 mm]
(23779)
Water Tight
Connector
.875Ø Uni-Bit
Drill a .875
22.23mm] Ø Hole
Wiring from Light
(Black Tube)
ATF Control Pan Light (230 VAC) Wiring
9
MF2476A
ATF Pan Light Wiring with Electronic Sensor
DANGER: Electrical Hazard
Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions
specifically state otherwise.
Ground all electrical equipment for safety.
All electrical wiring must be done by a qualified electrician in accordance with local and national electric codes.
Ground all non-current carrying metal parts to guard against electrical shock.
Electrical disconnects and over current protection are not supplied with the equipment.
Wiring
230 VAC Supply
Electronic Sensor
Motor
Figure 7.Electronic Sensor Wiring
ATF Pan Light
Green
Green
Black
White
Black (L1)
White (L2)
Black
Red
Blue
Brown
Piggy Back (9296)
Connector
Wiring ATF Control Pan Light (230 VAC)
10
MF2476A
ATF Pan Light with Mechanical Switch Wiring
Pan Light
230 VAC
Supply
Mechanical
Control Switch
Feed Line
Motor
Black (L1)
Black
Blue
Green
White (L2)
Green
Figure 8.Mechanical Switch Wiring
White
Black
Black
Black
ATF Control Pan Light (230 VAC) Parts Listing
11
MF2476A
Parts Listing
1
2476-001 2/2018
2
5
8
3
6
7
4
Item Description Part No.
1 ATF Pan Light 55494
2 Pan Light Bracket 55497
3 Water Tight Connector 23779
4 10" Black Tube 14454-10
5 .875 Bushing 3326
6 Plastic Nut 43662
7 Piggy Back Connector 9296
8 10-24 Lock Nut 34019
MADE TO WORK.
BUILT TO LAST.
®
Revisions to this Manual
Page No. Description of Change ECO
New Manual 33425
Contact your nearby Chore-Time distributor or representative for additional parts and information.
Chore-Time Group
A division of CTB, Inc.
PO Box 2000
Milford, Indiana 46542-2000 USA
Phone (574) 658-4101 Fax (877) 730-8825
E-mail:poultry@choretime.com
Internet: www.choretimepoultry.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Chore-Time MF2476A ATF Control Pan Light Installation and Operators Instruction Manual

Type
Installation and Operators Instruction Manual

Chore-Time MF2476A ATF Control Pan Light is a safety and control device designed to enhance the functionality and safety of your feeding system. It features a durable construction and weather-resistant design, making it suitable for various agricultural environments. The light assembly includes a water-tight connector and a plastic bushing for secure and reliable operation. The device can be easily installed on the pan shield using the provided mounting hardware.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI