Parameter list (by function group)
8
PARAMETER
2.2 Parameter list (by function group)
D: Operation command and
frequency command
Parameters that specify the inverter's command source, and
parameters that set the motor driving frequency and torque.
The setting is available for the FR-A800-E only.
H: Protective function parameter
Parameters to protect the motor and the inverter.
The setting is available for the FR-A800-E only.
M: Monitor display and monitor
output signal
Parameters regarding the inverter's operating status. These
parameters are used to set the monitors and output signals.
N: Operation via communication
and its settings
Parameters for communication operation. These parameters
set the communication specifications and operation.
The setting is available for the FR-F800-E only.
Pr.
group
Pr. Name
Refer
to
page
D012 550
NET mode operation command
source selection
9
D013 551
PU mode operation command
source selection
9
D400
804 Torque command source selection 40
Pr.
group
Pr. Name
Refer
to
page
H700 810 Torque limit input method selection 40
Pr.
group
Pr. Name
Refer
to
page
M400 190 RUN terminal function selection 13
M401 191 SU terminal function selection 13
M402 192 IPF terminal function selection 13
M403 193 OL terminal function selection 13
M404 194 FU terminal function selection 13
M405 195 ABC1 terminal function selection 13
M406 196 ABC2 terminal function selection 13
M410 313 DO0 output selection 13
M411 314 DO1 output selection 13
M412 315 DO2 output selection 13
Pr.
group
Pr. Name
Refer
to
page
N001 342
Communication EEPROM write
selection
15
N010 349
Communication reset selection/
Ready bit status selection
15
N013 502
Stop mode selection at
communication error
15
N014 779
Operation frequency during
communication error
15
N052 728
Device instance number (Upper 3
digits)
73
N053
729
Device instance number (Lower 4
digits)
73
N054
390 % setting reference frequency 73
N100 541 Frequency command sign selection 40
N103 544 CC-Link extended setting 40
N240 349 Ready bit status selection 15
N600 1434 Ethernet IP address 1 20
N601 1435 Ethernet IP address 2 20
N602 1436 Ethernet IP address 3 20
N603 1437 Ethernet IP address 4 20
N610 1438 Subnet mask 1 20
N611 1439 Subnet mask 2 20
N612 1440 Subnet mask 3 20
N613 1441 Subnet mask 4 20
N630 1427 Ethernet function selection 1 20
N631 1428 Ethernet function selection 2 20
N632 1429 Ethernet function selection 3 20
N641 1426
Link speed and duplex mode
selection
20
N642 1455 Keepalive time 20
N643 1431
Ethernet signal loss detection
function selection
20
N644 1432
Ethernet communication check time
interval
20
N650 1424
Ethernet communication network
number
20
N651 1425
Ethernet communication station
number
20
N660 1442 Ethernet IP filter address 1 20
N661 1443 Ethernet IP filter address 2 20
N662 1444 Ethernet IP filter address 3 20
N663 1445 Ethernet IP filter address 4 20
N664 1446
Ethernet IP filter address 2 range
specification
20
N665 1447
Ethernet IP filter address 3 range
specification
20
N666 1448
Ethernet IP filter address 4 range
specification
20
N670 1449
Ethernet command source selection
IP address 1
20
N671 1450
Ethernet command source selection
IP address 2
20
N672 1451
Ethernet command source selection
IP address 3
20
N673 1452
Ethernet command source selection
IP address 4
20
N674 1453
Ethernet command source selection
IP address 3 range specification
20
N675 1454
Ethernet command source selection
IP address 4 range specification
20
N681 1124
Station number in inverter-to-
inverter link
85
N682 1125
Number of inverters in inverter-to-
inverter
link system
85
Pr.
group
Pr. Name
Refer
to
page