FMI PF58-927-LS Operating instructions

Type
Operating instructions

This manual is also suitable for

INSTALLATION INSTRUCTIONS FOR
VENT FLEX MODELS PF58-927, PF58-1236, PF58-1854 AND VKF58-927
A ex vent section can be used in replace venting congura-
tions when an elbow or an offset may be needed.
WARNING: Do not connect 2 or more ex vent sec-
tions in a row. This will cause a re hazard.
NOTICE: Flex vent pipe must have a minimum 2'' clearance
to combustible material and 1
1
/
2
" through a combustible wall.
IMPORTANT: For horizontal venting,
1
/
4
" rise for every 1 foot
run is required for proper replace operation.
Spacer springs are included inside each ex vent section.
After bending ex vent section, position springs as shown
in Figure 1.
Flex vent pipe sections are designed with special twist-lock
connections. The female end of the pipes has locking lugs
(indentions). These lugs will slide straight into matching slots
on male end of adjacent pipe. Push pipe sections together
and twist one section clockwise approximately
1
/
4
" turn until
sections are fully locked (see Figure 2).
Note: Horizontal runs for venting must be supported every 3
feet. Use wall straps for this purpose.
See replace owner's manual for complete venting installa-
tion instructions.
Figure 2 - Flex Vent Pipe Connection
Figure 1 - Adjusting Spacer Springs
Spacer Springs
Inner Pipe
Outer Pipe
Flex Vent
Section
Certied for Use With Fireplace Model Series (V)TC36, (V)T32, (V)VC36/42,
(V)KC36/42, (V)CDC36R, (V)CDC36T, (V)CD36R, (V)CD36T, (V)DVF36TCL,
(V)DVF36TCR, (V)DVF36TSTA, (V)DVF36TPNA-A, (V)LDV43
Flex vent sections can be expanded to 3 times its compressed
(original) length. See chart below for model lengths.
Model Compressed
Flex Length
Compressed
Length With
Connectors
Expanded Flex
Length
Expanded
Length With
Connectors
PF58-927 9'' 17.5'' 27'' 35.5''
PF58-1236 12'' 20.5'' 36'' 44.5''
PF58-1854 18'' 26.5'' 54'' 62.5''
TERMINATION CONFIGURATIONS
Figure 3 and 3A (for models (V)LDV43 series), page 2, show
the acceptable conguration when venting horizontally us-
ing exible venting systems. Figure 4 shows the acceptable
conguration when installing in a corner. The vertical and
horizontal minimums and maximums shown in gures 3 and
3A, page 2, apply to Figure 4, page 2, as well. The ex vent
system must be designed and supported to prevent restric-
tion on the venting system. All bends must be made with a
minimum bend radius of 3'' plus the radius of the outer pipe
or as specied by the pipe manufacturer to prevent reduction
of pipe diameter. As with rigid pipe, ex vent must be pitched
upwards and supported without use of screws in vent pipe
to prevent sagging and damage.
Horizontal termination must be secured to ex venting using
4 self-drilling screws as shown in Figure 5. After placing ter-
mination onto ex vent, drill through pilot holes on termination
and into ex vent to create holes for the screws.
IMPORTANT: Horizontal square terminations require only
inner portion of wall restop. Horizontal installations using
round terminations require interior and exterior portion of
wall restop (see Figure 6, page 2).
120436-01
Rev. F
11/12
Figure 4 - Corner Venting Conguration
Figure 3 - Horizontal Venting Conguration
Figure 3A - Horizontal Venting Conguration
(For model (V)LDV43 Series)
Figure 5 - Attaching Vent to Flex Venting
Figure 6 - Horizontal Termination Conguration for
Round Terminations
2'' Minimum
Use Standoff for
siding or Stucco
Horizontal Square
Termination (Shown)
(HTS-58)
Horizontal Round
Termination (HTT-58)
Not to Exceed Horizontal Run
Limit (See Owner's Manual
for Model LDV43 Series
Horizontal
Square
Termination
Shown
Wall Firestop
(WF-58)
Wall Firestop
Flex
Venting
53'' Min. Plus
1/4'' Rise per
Foot
1 Ft. Minimum
Rigid Pipe
Required
TOH
Square Termination
Vertical (V) Horizontal (H)
32
3
/
4
" min. 17'' Max
Flex Venting
TOH
Drill Through Termination
and into Flex
Round Termination
Wall
Firestop
Horizontal
Round
Termination
45° Elbow
Exterior
portion of Wall
Firestop (Round
Termination Only)
Manufactured at:
2701 S. Harbor Blvd.
Santa Ana, CA 92704
www.fmiproducts.com
© 2010 FMI PRODUCTS, LLC
All Rights Reserved
PFS
®
USC
  • Page 1 1
  • Page 2 2

FMI PF58-927-LS Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI