MODEL: K-X2P
INVERTER GENERATOR
PARALLEL CABLE KIT
03/2015
IMPORTANT INFORMATION
1-YEAR
LIMITED WARRANTY
FOR THIS PARALLEL CABLE KIT
KING CANADA TOOLS
OFFERS A 1-YEAR LIMITED WARANTY
FOR NON COMMERCIAL USE.
PROOF OF PURCHASE
Please keep your dated proof of purchase for warranty and servicing purposes.
LIMITED TOOL WARRANTY
King Canada makes every effort to ensure that this product meets high quality and
durability standards. King Canada warrants to the original retail consumer a 1-year
limited warranty as of the date the product was purchased at retail and that each
product is free from defects in materials. Warranty does not apply to defects due
directly or indirectly to misuse, abuse, normal wear and tear, negligence or
accidents, repairs done by an unauthorized service center, alterations and lack of
maintenance. King Canada shall in no event be liable for death, injuries to persons
or property or for incidental, special or consequential damages arising from the use
of our products.
To take advantage of this limited warranty, return the product at your expense
together with your dated proof of purshase to an authorized King Canada service
center. Contact your retailer or visit our web site at www.kingcanada.com for an
updated listing of our authorized service centers. In cooperation with our authorized
serviced center, King Canada will either repair or replace the product if any part or
parts covered under this warranty which examination proves to be defective in
workmanship or material during the warranty period.
NOTE TO USER
This instruction manual is meant to serve as a guide only. Specifications and
references are subject to change without prior notice.
PARTS DIAGRAM & PARTS LISTS
Refer to the Parts section of the King Canada web site for the most updated parts
diagram and parts list.
KING CANADA INC. DORVAL, QUÉBEC, CANADA H9P 2Y4
www.kingcanada.com
SAFETY
FOLLOW THESE INSTRUCTIONS CAREFULLY
Proper installation of the Parallel Cable Kit is essential for safe and reliable operation.
WARNING!
This Parallel Cable Kit must ONLY be used between two identical Inverter
Generators. Never connect cables between two different inverter generators, this may
cause low voltage output, which can permanently damage the electrical devices
connected to the inverter generators.
Before use, read and understand the installation and operation instructions in this manual
to become familiar with how this Parallel Cable Kit works with two Inverter Generators with
parallel ports.
Periodically inspect the cables for damage, replace cable if its insulation is broken or
cracked.
INSTALLATION
1) Connect the two parallel connectors (A)
Fig.1 from one cable to the parallel inputs
(B) on the control panel of the first Inverter
Generator.
2) Connect the two parallel connectors from
the other cable to the parallel inputs on the
control panel of the second Inverter
Generator.
3) Attach the ground wire (C) Fig.1 to the ground terminal (D) on the control panel of the
first Inverter Generator.
4) Attach the second ground wire to the ground terminal on the control panel of the
second Inverter Generator.
SAFETY AND INSTALLATION
Figure 1
OPERATION
OPERATION
Warning! If high electrical loads are
connected, turn the Eco switch (A) Fig.2 to
the Off position to reduce voltage changes.
While both Inverter Generators are running,
make sure both green power indicator lights
(B) are On. If not On, turn the Inverter
Generators Off, restart both Inverter
Generators and make sure both green power
indicator lights are On.
Warning! Substantial overloading (exceeding
the rated output of 30 Amps.) will shut off the AC output. Exceeding maximum power or
slightly overloading the Inverter Generators may not switch the AC circuit protector Off, but
will shorten the service life of the Inverter Generators. Do not overload.
Warning! Only use one Parallel Cable receptacle at a time
(NEMA L5-30R or the NEMA TT-30R). When using the
Parallel Cable Kit, the 120V duplex receptacles on the
Inverter Generator control panels can not be used, only the
receptacles on the Parallel Cable box can be used.
This Parallel Cable kit comes with two receptacles;
•  NEMA L5-30R Twist Lock Receptacle (A) Fig.3- Rated for
120V, max. 30 Amps. Powers electrical items having a 3
prong NEMA L5-30P Twist Lock plug.
•  NEMA TT-30R RV Receptacle (B) Fig.3-Rated for 120V,
max. 30 Amps. Connect an RV power cable having a 3
prong TT-30P RV plug.
Figure 2
Figure 3