Full Facepiece Reusable Respirator 6800 Medium 4 EA/Case

3M Full Facepiece Reusable Respirator 6800 Medium 4 EA/Case, Full Facepiece Reusable Respirator 6700 Small 4 EA/Case, Full Facepiece Reusable Respirator 6700DIN Small 4 EA/Case, Full Facepiece Reusable Respirator 6800DIN, Medium 4 EA/Case, Full Facepiece Reusable Respirator 6900 Large 4 EA/Case, Full Facepiece Reusable Respirator 6900DIN Large 4 EA/Case, Lens Assembly 6898/37006(AAD), Replacement Part 5 EA/Case Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the 3M Full Facepiece Reusable Respirator 6800 Medium 4 EA/Case Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
6898/37006*
Lens Assembly
Replacement Instructions
Important: Keep these User Instructions for reference
*37006 is a catalog number only. NIOSH approved as 3M
TM
Lens Assembly 6898.
See the 3M
TM
Full Facepiece 6000 User Instructions for approval label.
38-9018-9555-7 (Supersedes 38-9018-7177-2) 3/1/06
Fig. 1 Fig. 2
The 3M
TM
6898 Lens Assembly consists of a hard coated polycarbonate lens with installed bayonet
attachment inhalation port fittings, inhalation valves and inhalation port filter/cartridge gaskets.
The lens is replaceable by following these steps:
1. Remove nose cup assembly from inside facepiece. (Fig. 1)
2. Remove center adapter assembly by turning counter-clockwise 14 turn and withdrawing from lens center
port. (Fig. 2)
2
Fig. 3
3. Remove the (2) phillips screws from the lens/faceseal frame. Pull the frame top and bottom away from
faceseal.
4. Remove faceseal from lens.
5. Place new lens and faceseal together aligning marks at top and bottom. Position top and bottom frame,
again aligning marks top and bottom. (Fig. 3) Install and securely tighten screws. Make certain
alignment marks are properly aligned top and bottom with all components.
6. Install center adapter assembly.
7. Replace nose cup assembly.
FOR MORE INFORMATION
In United States, contact:
Internet: www.3M.com/occsafety
Technical Assistance: 1-800-243-4630
For other 3M products:
1-800-3M-HELPS or
1-651-737-6501
3M Occupational Health and
Environmental Safety Division
3M Center, Building 0235-02-W-70
St. Paul, MN 55144-1000
©3M 2005 38-9018-9555-7
/