Sinclair SND-01 User manual

Type
User manual
USER'S MANUAL
LIGHT BOARD INTERFACE
SND-01
TRACE SERIES
Original instructions
Light board SND-01
1
1. Introduction
Light board interface SND-01 offer you a possibility to control SINCLAIR duct type units from NEW
UNI DC INVERTER series with wireless remote controller without need of wired controller.
Also light board shows set temperature, current running mode, measure room temperature and
allows you basic control of the unit.
2. Installation
Light board is installed directly to the wall or to base socket box. Installation dimensions are on
pictures below.
Fig. 1. Back view
Fig. 2. Side view
Light board SND-01
2
3. Wiring
Wires from light board are equipped with the connectors and are connected directly to the main
board of the duct indoor unit. Connection terminal is number 6 on fig. 3.
Fig. 3. Duct indoor main board
Length of the cable is 1,6 m.
Installation of wired controller in the same time as light board interface is possible. Both controllers
can be connected at the same time.
Light board SND-01
3
4. Control
For control of the unit when light board interface is installed is used wireless remote controller or
two buttons on the front panel of the interface. Description of the front panel is on fig. 4.
Fig. 4. Description of the front panel
Power/Running indicating lamp
When unit is off indicator is RED and when unit
is running indicator is GREEN
Cooling indicating lamp
Light ON when unit is in cooling mode,
otherwise light OFF
Heating indicating lamp
Light ON when unit is in heating mode,
otherwise light OFF
Dehumidification indicating lamp
Light ON when unit is in dehumidification mode,
otherwise light OFF
88 Display
Shows set temperature or error codes
Receiver
Receive signal from wireless remote controller
Cool button
When is button pressed in OFF state of the unit
it will turn unit to ON in cooling mode*, when is
unit in ON mode press button to turn off unit
Heat button
When is button pressed in OFF state of the unit
it will turn unit to ON in heating mode**, when is
unit in ON mode press button to turn off unit
*Cooling mode: set temperature 26 °C, low fan speed
**Heating mode: set temperature 20 °C, low fan speed
NOTE CONCERNING PROTECTION OF
ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be
taken to a collection station for the recycling of electrical and electronic devices. The symbol on the
product, the operating instructions or the packaging indicate such disposal procedures. The materials
are recyclable in accordance with their respective symbols. By means of re-use, material recycling or
any other form of recycling old appliances you are making an important contribution to the protection
of our environment. Please ask your local council where your nearest disposal station is located.
PRODUCER
SINCLAIR CORPORATION Ltd.
1-4 Argyll St.
LONDON
W1F 7LD
United Kingdom
www.sinclair-world.com
This product was manufactured in China (Made in China).
REPRESENTATIVE, TECHNICAL SUPPORT
Purkyňova 45
612 00 Brno
Czech republic
Tel.: +420 541 590 140
Fax: +420 541 590 124
www.sinclair-solutions.com
info@sinclair-solutions.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Sinclair SND-01 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI